SLE-AM-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
4
Rows
4
Columns
30
.1.3.6.1.4.1.6296.101.15.2.1 · 1 row entry · 9 columns
This table is the class Master Alarm table. 
It gets populated when system init is done. 
And it contains all the class alarms supported for the device
sleAMConfigEntry entry .1.3.6.1.4.1.6296.101.15.2.1.1
Indexes
sleAMConfigAlarmClassId sleAMConfigAlarmId
Column Syntax OID
sleAMConfigAlarmClassId
Class ID starts from 1 to 65535 for the system.
And these IDs are defined by alarm-client
AMAlarmClassId
Textual Convention: AMAlarmClassId Integer32
Type Constraints:
range: 1..65535
.1.3.6.1.4.1.6296.101.15.2.1.1.1
sleAMConfigAlarmId
Alarm ID
Alarm ID starts from 1 to 65535 for the system.
And these IDs are defined by alarm-client
AMAlarmId
Textual Convention: AMAlarmId Integer32
Type Constraints:
range: 1..65535
.1.3.6.1.4.1.6296.101.15.2.1.1.2
sleAMConfigAlarmName
Alarm Name string
OctetStringr/w .1.3.6.1.4.1.6296.101.15.2.1.1.3
sleAMConfigAlarmSeverity
Alarm severity: The default severity is pre-defined by each Alarm manager clients
critical(1),
major(2),
minor(3),
warning(4),
intermediate(5),
AMAlarmSeverity
Textual Convention: AMAlarmSeverity Enumeration
Type Values:
1critical
2major
3minor
4warning
5intermediate
6default
.1.3.6.1.4.1.6296.101.15.2.1.1.4
sleAMConfigAlarmEnableState
Alarm Trap State. Based on the trap state,
the alarm will be notified to NMS. If the TRAP STATE is enabled
then the alarm will be notified else wont be notified.
enable (1)
disabe (0)
AMTrapState
Textual Convention: AMTrapState Enumeration
Type Values:
0disable
1enable
.1.3.6.1.4.1.6296.101.15.2.1.1.5
sleAMConfigAlarmRaiseGuardTime
Alarm raise Soaking time.
When any alarm is raised, this attribute
specifies how much time the alarm should be soaked before notifying
to Alarm manager
range:1 ~ 30, (if '0', no soaking time)
AMAlarmGuardTime
Textual Convention: AMAlarmGuardTime Integer32
Type Constraints:
range: 0..30
.1.3.6.1.4.1.6296.101.15.2.1.1.6
sleAMConfigAlarmClearGuardTime
Alarm clear Soaking time. When any alarm is cleared, this attribute
specifies how much time the alarm should be soaked before notifying
to Alarm manager
range:1 ~ 30, (if '0', no soaking time)
AMAlarmGuardTime
Textual Convention: AMAlarmGuardTime Integer32
Type Constraints:
range: 0..30
.1.3.6.1.4.1.6296.101.15.2.1.1.7
sleAMConfigAlarmLed
Alarm led configuration.
Determinde led operate or not, when alarms occur.
off(0): led not operate
on(1) : led operate
Enumerationr/w
Enumerated Values:
0off
1on
.1.3.6.1.4.1.6296.101.15.2.1.1.8
sleAMConfigSpecificId
Alarm Configuration specific ID(4bytes)
classId and alarmID are combinded with a specificID
* 1st,2nd Bytes - ClassId
* 3rd,4th bytes - alarmID
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6296.101.15.2.1.1.9
.1.3.6.1.4.1.6296.101.15.3.1 · 1 row entry · 9 columns
This table contains the current active
alarms for the Alarm Class. Each Row in this table
gets populated when any Alarm is raised
sleAMCurrentEntry entry .1.3.6.1.4.1.6296.101.15.3.1.1
Indexes
sleAMCurrentSeqId
Column Syntax OID
sleAMCurrentSeqId
alarm sequence id
key of current alarm table
it generated by alarm-manager automatically
Unsigned32
Constraints:
range: 1-65535
.1.3.6.1.4.1.6296.101.15.3.1.1.1
sleAMCurrentAlarmSource
alarm location infomation

|type|length|value|type|length|value|....
type (1-byte) : alarm location type
length(1-byte) : alarm location value length
value (length-bytes) : alarm location value
AMAlarmSrc
Textual Convention: AMAlarmSrc OctetString
Type Constraints:
range: 68
.1.3.6.1.4.1.6296.101.15.3.1.1.2
sleAMCurrentAlarmClassId
Class ID starts from 1 to 65535 for the system.
And these IDs are defined by alarm-client
AMAlarmClassId
Textual Convention: AMAlarmClassId Integer32
Type Constraints:
range: 1..65535
.1.3.6.1.4.1.6296.101.15.3.1.1.3
sleAMCurrentAlarmId
Alarm ID
Alarm ID starts from 1 to 65535 for the system.
And these IDs are defined by alarm-client
AMAlarmId
Textual Convention: AMAlarmId Integer32
Type Constraints:
range: 1..65535
.1.3.6.1.4.1.6296.101.15.3.1.1.4
sleAMCurrentAlarmStatus
Current Alarm State:
raised (1),
masked(2)
AlarmStatus
Textual Convention: AlarmStatus Enumeration
Type Values:
0cleared
1raised
2masked
3disabled
4forcedClear
5event
6unmasked
.1.3.6.1.4.1.6296.101.15.3.1.1.5
sleAMCurrentAlarmSeverity
Current Alarm Severity:
critical(1),
major(2),
minor(3),
warning(4)
AMAlarmSeverity
Textual Convention: AMAlarmSeverity Enumeration
Type Values:
1critical
2major
3minor
4warning
5intermediate
6default
.1.3.6.1.4.1.6296.101.15.3.1.1.6
sleAMCurrentAlarmReason
reasion string
AMAlarmReason
Textual Convention: AMAlarmReason OctetString
Type Constraints:
range: 0..256
.1.3.6.1.4.1.6296.101.15.3.1.1.7
sleAMCurrentTimeAndDate
Current Alarm Time and Date
SNMPv2-SMITimeTicks
Textual Convention: SNMPv2-SMITimeTicks Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.6296.101.15.3.1.1.8
sleAMCurrentSpecificId
Current Alarm specific ID(4bytes)
classId and alarmID are combinded with a specificID
* 1st,2nd Bytes - ClassId
* 3rd,4th bytes - alarmID
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6296.101.15.3.1.1.9
.1.3.6.1.4.1.6296.101.15.4.1 · 1 row entry · 9 columns
This Table is used to for keeping the Alarm History
sleAMHistoryEntry entry .1.3.6.1.4.1.6296.101.15.4.1.1
Indexes
sleAMHistorySeqId
Column Syntax OID
sleAMHistorySeqId
Alarm History Sequence ID. This sequence Id is
maintained based on the TRAP sent.
Unsigned32
Constraints:
range: 1-65535
.1.3.6.1.4.1.6296.101.15.4.1.1.1
sleAMHistoryAlarmSource
|type|length|value|type|length|value|....

type (1-byte) : alarm location type
length(1-byte) : alarm location value length
value (length-bytes) : alarm location value
AMAlarmSrc
Textual Convention: AMAlarmSrc OctetString
Type Constraints:
range: 68
.1.3.6.1.4.1.6296.101.15.4.1.1.2
sleAMHistoryAlarmClassId
Class ID starts from 1 to 65535 for the system.
And these IDs are defined by alarm-client
AMAlarmClassId
Textual Convention: AMAlarmClassId Integer32
Type Constraints:
range: 1..65535
.1.3.6.1.4.1.6296.101.15.4.1.1.3
sleAMHistoryAlarmId
History Alarm ID
Alarm ID starts from 1 to 65535 for the system.
And these IDs are defined by alarm-client
AMAlarmId
Textual Convention: AMAlarmId Integer32
Type Constraints:
range: 1..65535
.1.3.6.1.4.1.6296.101.15.4.1.1.4
sleAMHistoryAlarmStatus
History Alarm State:
cleared (0),
raised (1),
masked(2)
AlarmStatus
Textual Convention: AlarmStatus Enumeration
Type Values:
0cleared
1raised
2masked
3disabled
4forcedClear
5event
6unmasked
.1.3.6.1.4.1.6296.101.15.4.1.1.5
sleAMHistoryAlarmSeverity
History alarm Severity
critical(1),
major(2),
minor(3),
warning(4)
AMAlarmSeverity
Textual Convention: AMAlarmSeverity Enumeration
Type Values:
1critical
2major
3minor
4warning
5intermediate
6default
.1.3.6.1.4.1.6296.101.15.4.1.1.6
sleAMHistoryAlarmReason
History alarm Reason string
AMAlarmReasonr/w
Textual Convention: AMAlarmReason OctetString
Type Constraints:
range: 0..256
.1.3.6.1.4.1.6296.101.15.4.1.1.7
sleAMHistoryAlarmTimeDate
History Alarm Time and Date
SNMPv2-SMITimeTicks
Textual Convention: SNMPv2-SMITimeTicks Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.6296.101.15.4.1.1.8
sleAMHistorySpecificId
Alarm History specific ID(4bytes)
classId and alarmID are combinded with a specificID
* 1st,2nd Bytes - ClassId
* 3rd,4th bytes - alarmID
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6296.101.15.4.1.1.9
.1.3.6.1.4.1.6296.101.15.6.1 · 1 row entry · 3 columns
This table contains the LED status and configuration.
sleAMLedEntry entry .1.3.6.1.4.1.6296.101.15.6.1.1
Indexes
sleAMLedSeverity
Column Syntax OID
sleAMLedSeverity
LED Alarm Severity
critical(1),
major(2),
minor(3),
Enumerationr/w
Enumerated Values:
1critical
2major
3minor
.1.3.6.1.4.1.6296.101.15.6.1.1.1
sleAMLedSet
ACO control configuration
acoOff(1) : buzzer operation enable.
acoOn(2) : buzzer operation disable.
acoOpr(3) : current buzzer cut.
AMAlarmLedr/w
Textual Convention: AMAlarmLed Enumeration
Type Values:
1setLedOff
2setLedOn
3oprLed
.1.3.6.1.4.1.6296.101.15.6.1.1.2
sleAMLedCount
alarm count of the associated led
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6296.101.15.6.1.1.3