sleAMConfigEntry
SLE-AM-MIB ·
.1.3.6.1.4.1.6296.101.15.2.1.1
Object
row
No description available.
Context
- MIB
- SLE-AM-MIB
- OID
.1.3.6.1.4.1.6296.101.15.2.1.1- Type
- row
- Status
- current
- Parent
- sleAMConfigTable
- Table
- sleAMConfigTable
- Children
- 9
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| sleAMConfigAlarmClassId Class ID starts from 1 to 65535 for the system.
And these IDs are defined by alarm-client | column | AMAlarmClassId | .1.3.6.1.4.1.6296.101.15.2.1.1.1 |
| sleAMConfigAlarmId Alarm ID
Alarm ID starts from 1 to 65535 for the system.
And these IDs are defined by alarm-client | column | AMAlarmId | .1.3.6.1.4.1.6296.101.15.2.1.1.2 |
| sleAMConfigAlarmName Alarm Name string | column | OctetString | .1.3.6.1.4.1.6296.101.15.2.1.1.3 |
| sleAMConfigAlarmSeverity Alarm severity: The default severity is pre-defined by each Alarm manager clients
critical(1),
major(2),
minor(3),
warning(4),
intermediate(5), | column | AMAlarmSeverity | .1.3.6.1.4.1.6296.101.15.2.1.1.4 |
| sleAMConfigAlarmEnableState Alarm Trap State. Based on the trap state,
the alarm will be notified to NMS. If the TRAP STATE is enabled
then the alarm will be notified else wont be notified.
enable (1)
disa… | column | AMTrapState | .1.3.6.1.4.1.6296.101.15.2.1.1.5 |
| sleAMConfigAlarmRaiseGuardTime Alarm raise Soaking time.
When any alarm is raised, this attribute
specifies how much time the alarm should be soaked before notifying
to Alarm manager
range:1 ~ 30, (if '0', no … | column | AMAlarmGuardTime | .1.3.6.1.4.1.6296.101.15.2.1.1.6 |
| sleAMConfigAlarmClearGuardTime Alarm clear Soaking time. When any alarm is cleared, this attribute
specifies how much time the alarm should be soaked before notifying
to Alarm manager
range:1 ~ 30, (if '0', no … | column | AMAlarmGuardTime | .1.3.6.1.4.1.6296.101.15.2.1.1.7 |
| sleAMConfigAlarmLed Alarm led configuration.
Determinde led operate or not, when alarms occur.
off(0): led not operate
on(1) : led operate | column | Enumeration | .1.3.6.1.4.1.6296.101.15.2.1.1.8 |
| sleAMConfigSpecificId Alarm Configuration specific ID(4bytes)
classId and alarmID are combinded with a specificID
* 1st,2nd Bytes - ClassId
* 3rd,4th bytes - alarmID | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6296.101.15.2.1.1.9 |
Indexes
| Object | Type | Syntax | OID |
|---|---|---|---|
| sleAMConfigAlarmClassId Class ID starts from 1 to 65535 for the system.
And these IDs are defined by alarm-client | column | AMAlarmClassId | .1.3.6.1.4.1.6296.101.15.2.1.1.1 |
| sleAMConfigAlarmId Alarm ID
Alarm ID starts from 1 to 65535 for the system.
And these IDs are defined by alarm-client | column | AMAlarmId | .1.3.6.1.4.1.6296.101.15.2.1.1.2 |