PKT-STORM-CTRL-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
1
Rows
1
Columns
12
swPktStormCtrlTable
table.1.3.6.1.4.1.171.12.25.3.1
·
1 row entry
·
12 columns
A table that contains information about packet storm control. A S/W mechanism is provided to monitor the traffic rate in addition to the H/W storm control mechanism. If the traffic rate is too high, this port will be shut down.
A list of information for each port of the device.
Indexes
swPktStormCtrlPortIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
swPktStormCtrlPortIndex
This object indicates the device's port number.(1..Max port
number in the device).It is used to specify a range of ports to be configured. |
Integer32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.171.12.25.3.1.1.1 |
||||
|
swPktStormCtrlthreshold
obsolete
This object is the upper threshold at which the specified storm control will turn on.
Note: The max entry range is (M..N), the value M means the minimum number, the value N means the maximuim number, it is determined by… |
SNMPv2-SMIInteger32r/w Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.171.12.25.3.1.1.2 |
||||
|
swPktStormCtrlBroadcastStatus
This object indicates whether the broadcast storm control is enabled or disabled.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.171.12.25.3.1.1.3 |
||||
|
swPktStormCtrlMulticastStatus
This object indicates whether the multicast storm control is enabled or disabled.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.171.12.25.3.1.1.4 |
||||
|
swPktStormCtrlUnicastStatus
This object indicates whether the unicast(Destination Loopback Fail) storm control is enabled
or disabled. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.171.12.25.3.1.1.5 |
||||
|
swPktStormCtrlActionStatus
There are two actions to take for storm control, shutdown and drop. The
former is implemented in S/W, and the latter is implemented in H/W. If a user chooses shutdown, they will need to configure both the back_off and t… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.171.12.25.3.1.1.6 |
||||
|
swPktStormCtrlCountDown
If a packet storm has been encountered continuously on a given port for a long
period of time (indicated by the value of this object), the port will be shut down forever until it's recovered manually. Note: The max entr… |
minutesSNMPv2-SMIInteger32r/w Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.171.12.25.3.1.1.7 |
||||
|
swPktStormCtrlTimeinterval
This object is the sampling interval of received packet counts.
Note: The max entry range is (M..N), the value M means the minimum number, the value N means the max number, it is determined by the project itself. |
secondsSNMPv2-SMIInteger32r/w Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.171.12.25.3.1.1.8 |
||||
|
swPktStormCtrlShutdownForever
This object indicates whether the storm control is shut down forever or not.
This command recover it manually. If support auto-recover mechanism, the object is no use. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.171.12.25.3.1.1.9 |
||||
|
swPktStormCtrlBCastThreshold
The upper threshold at which the specified storm control will turn on.
Note: The max entry range is (M..N), the value M means the minimum number, the value N means the maximuim number, it is determined by the project it… |
SNMPv2-SMIInteger32r/w Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.171.12.25.3.1.1.10 |
||||
|
swPktStormCtrlMCastThreshold
This object indicates the upper threshold at which the specified storm control will turn on.
Note: The max entry range is (M..N), the value M means the minimum number, the value N means the maximuim number, it is determ… |
SNMPv2-SMIInteger32r/w Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.171.12.25.3.1.1.11 |
||||
|
swPktStormCtrlUnicastThreshold
This object indicates the upper threshold at which the specified storm control will turn on.
Note: The max entry range is (M..N), the value M means the minimum number, the value N means the maximuim number, it is determ… |
SNMPv2-SMIInteger32r/w Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.171.12.25.3.1.1.12 |