swPktStormCtrlCountDown

PKT-STORM-CTRL-MIB · .1.3.6.1.4.1.171.12.25.3.1.1.7

Object

column r/w minutes SNMPv2-SMIInteger32
If a packet storm has been encountered continuously on a given port for a long
period of time (indicated by the value of this object), the port will be shut
down forever until it's recovered manually.
Note:
The max entry range is (-1..N), the value N means the maximum number, it is 
determined by the project itself.
              
Value 0 to disable the function of shutdown forever.
              
Value -1 means disable the countdown timer, When the action is shutdown and countdown time is disabled, 
	 when the switch detects storm, it will shutdown the port directly.

Context

MIB
PKT-STORM-CTRL-MIB
OID
.1.3.6.1.4.1.171.12.25.3.1.1.7
Type
column
Access
readwrite
Status
current
Units
minutes
Parent
swPktStormCtrlEntry
Table
swPktStormCtrlTable
Siblings
11

Syntax

minutes SNMPv2-SMIInteger32
Source
SNMPv2-SMIInteger32
Base type
Integer32

Values & Constraints

Type Constraints
range: -2147483648..2147483647

Related Objects

Sibling Objects