OMNITRON-TRAP-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
3
Rows
3
Columns
15
.1.3.6.1.4.1.7342.12.1.1 · 1 row entry · 4 columns
This table supports the configuration and source filtering of SNMP
notifications generated by Omnitron management modules.
ostTrapCfgEntry entry .1.3.6.1.4.1.7342.12.1.1.1
This is a Trap Filtering configuration table entry.
Indexes
ostTrapCfgTrapCode
Column Syntax OID
ostTrapCfgTrapCode
An index to the Trap Configuration table. The entry (index) corresponds
to the 'trapcode' object indicating a specific trap code for an SNMP
notification.

Standard Omnitron traps are listed as 1 through 9…
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.7342.12.1.1.1.1
ostTrapCfgFilteringEnable
This object selects whether the notification indicated by the
ostTrapFilteringTrapCode object is filtered or is generated when
the specific condition is encountered.

noFiltering (1) Notification is gene…
Enumerationr/w
Enumerated Values:
1noFiltering
2filtering
.1.3.6.1.4.1.7342.12.1.1.1.2
ostTrapCfgStatus
*** NOT SUPPORTED ***
This object has been deprecated.
Enumerationr/w
Enumerated Values:
1trapNotActive
2trapActive
.1.3.6.1.4.1.7342.12.1.1.1.3
ostTrapCfgSeverity
This object indicates the severity configuration of a SNMP trap. Each
trap is able to have a separate severity configuration.

trapSeverityInformation(1) Trap is of informational severity only and
Enumerationr/w
Enumerated Values:
1trapSeverityInformation
2trapSeverityWarning
3trapSeverityMinor
4trapSeverityMajor
5trapSeverityCritical
.1.3.6.1.4.1.7342.12.1.1.1.4
.1.3.6.1.4.1.7342.12.1.3 · 1 row entry · 5 columns
This table supports the status of alarms generated by Omnitron
management modules.
ostAlarmStatusEntry entry .1.3.6.1.4.1.7342.12.1.3.1
This the Alarm Status table entry.
Indexes
ostAlarmStatusIndex
Column Syntax OID
ostAlarmStatusIndex
An index to the Alarm Status table.

Alarm Status table indices are assigned sequentially by the SNMP
Agent. When initialized the starting index number is 1.

An entry is added to the table d…
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.7342.12.1.3.1.1
ostAlarmStatusIdentifier
The specific alarm number. This object can take one of the following
values:

Number Alarm Description
------ ---------------------------
1 Module Lost
2 Link Down
3 Temperature
4 …
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.7342.12.1.3.1.2
ostAlarmStatusInstance
The specific alarm unique instance number. This object can take one
of the following octet formats dependent upon the scope of the alarm:

Scope Format
-------- ------
module 'Chassi…
OctetStringr/w
Constraints:
range: 0-64
.1.3.6.1.4.1.7342.12.1.3.1.3
ostAlarmStatusTime
The time when the alarm was added to the Alarm Table.
SNMPv2-TCDateAndTime
Textual Convention: SNMPv2-TCDateAndTime OctetString
Type Constraints:
range: 8
range: 11
.1.3.6.1.4.1.7342.12.1.3.1.4
ostAlarmStatusDescription
The description of the specific alarm.
OctetString
Constraints:
range: 0-64
.1.3.6.1.4.1.7342.12.1.3.1.5
.1.3.6.1.4.1.7342.12.1.5 · 1 row entry · 6 columns
This table supports the history of cleared alarms generated by Omnitron
management modules.
ostAlarmHistoryEntry entry .1.3.6.1.4.1.7342.12.1.5.1
This the Alarm Historytable entry.
Indexes
ostAlarmHistoryIndex
Column Syntax OID
ostAlarmHistoryIndex
An index to the Alarm History table.

Alarm History table indices are assigned sequentially by the SNMP
Agent. When initialized the starting index number is 1.

An entry is added to the table…
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.7342.12.1.5.1.1
ostAlarmHistoryIdentifier
The specific alarm number. This object can take one of the values
defined by the ostAlarmStatusIdentifier object.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.7342.12.1.5.1.2
ostAlarmHistoryInstance
The specific alarm unique instance number. This object takes one of
the formats defined by the ostAlarmStatusInstance object.
OctetString
Constraints:
range: 0-64
.1.3.6.1.4.1.7342.12.1.5.1.3
ostAlarmHistoryStartTime
The time when the alarm was added to the Alarm Status Table.
SNMPv2-TCDateAndTime
Textual Convention: SNMPv2-TCDateAndTime OctetString
Type Constraints:
range: 8
range: 11
.1.3.6.1.4.1.7342.12.1.5.1.4
ostAlarmHistoryEndTime
The time when the alarm was removed from the Alarm Status Table.
SNMPv2-TCDateAndTime
Textual Convention: SNMPv2-TCDateAndTime OctetString
Type Constraints:
range: 8
range: 11
.1.3.6.1.4.1.7342.12.1.5.1.5
ostAlarmHistoryDescription
The description of the specific alarm.
OctetString
Constraints:
range: 0-64
.1.3.6.1.4.1.7342.12.1.5.1.6