METRO1500-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
9
Rows
9
Columns
99
.1.3.6.1.4.1.2544.1.3.1.1.10 · 1 row entry · 4 columns
Table of Trapsinks
metro1500MainTrapsinkEntry entry .1.3.6.1.4.1.2544.1.3.1.1.10.1
Entries in the Trapsink Table
Indexes
metro1500MainTrapsinkNumber
Column Syntax OID
metro1500MainTrapsinkNumber mandatory
Number of Trapsink
Integer32
Constraints:
range: 1-10
.1.3.6.1.4.1.2544.1.3.1.1.10.1.1
metro1500MainTrapsinkAddress mandatory
IP Address of the Management System which should receive SNMP
Traps. The Logfiles are also shown in this Table
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.2544.1.3.1.1.10.1.2
metro1500MainTrapsinkCommunity mandatory
Community String which is sent with a SNMP Trap to the
Management Station
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.2544.1.3.1.1.10.1.3
metro1500MainTrapsinkPriority mandatory
Priority of the Trapsink (lower level gets less Traps)
Integer32
Constraints:
range: 1-20
.1.3.6.1.4.1.2544.1.3.1.1.10.1.4
.1.3.6.1.4.1.2544.1.3.1.1.11 · 1 row entry · 4 columns
Table of Log Files
metro1500MainLogfileEntry entry .1.3.6.1.4.1.2544.1.3.1.1.11.1
Entries in the Logfile Table
Indexes
metro1500MainLogfileNumber
Column Syntax OID
metro1500MainLogfileNumber mandatory
Number of Logfile
Integer32
Constraints:
range: 1-2
.1.3.6.1.4.1.2544.1.3.1.1.11.1.1
metro1500MainLogfileName mandatory
Name of Logfile
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.2544.1.3.1.1.11.1.2
metro1500MainLogfileSize mandatory
Size of Logfile
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2544.1.3.1.1.11.1.3
metro1500MainLogfilePriority mandatory
Priority of Logfile
Integer32
Constraints:
range: 1-20
.1.3.6.1.4.1.2544.1.3.1.1.11.1.4

metro1500SlotTable

table mandatory
.1.3.6.1.4.1.2544.1.3.1.2 · 1 row entry · 10 columns
Table of installed METRO1500 Components. Since METRO1500 can
handle many different Components, in this Section only the
common Information is displayed.  Component specific
Information is stored in different Subtrees.
metro1500SlotEntry entry .1.3.6.1.4.1.2544.1.3.1.2.1
Installed METRO1500 Components
Indexes
metro1500SlotNumber
Column Syntax OID
metro1500SlotNumber mandatory
Slot Number of installed Component. The Device
Master has always Slot Number 0 and is shown in the
Main section.
Integer32
Constraints:
range: 1-79
.1.3.6.1.4.1.2544.1.3.1.2.1.1
metro1500Type mandatory
Type of installed Component
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.2544.1.3.1.2.1.2
metro1500SlotTypeNumber mandatory
Integer Number between 0 and 255 unique for a
specific type of installed Component. This
Number can be used for management Systems to
handle automatically the different Options
of installed Components.
Enumeration
Enumerated Values:
1metro1500Converter
2metro1000Converter
3metro1000EthernetConverter
5metro1500-2-5GbConverter
7metro1500-TRL-Converter
10metro1500-4PortTDMCard
32nemi
33demi
39metro1500-EthernetHubCard
64switch
255other
.1.3.6.1.4.1.2544.1.3.1.2.1.3
metro1500SerialNumber mandatory
Serial Number of installed Component
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.2544.1.3.1.2.1.4
metro1500HardwareVersion mandatory
Hardware Version of installed Component
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.2544.1.3.1.2.1.5
metro1500SoftwareVersion mandatory
SoftwareVersion of installed Component
RFC1213-MIBDisplayString
Textual Convention: RFC1213-MIBDisplayString OctetString
.1.3.6.1.4.1.2544.1.3.1.2.1.6
metro1500Temperature mandatory
Temperature of installed Component in
Celsius
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2544.1.3.1.2.1.7
metro1500BoardVoltage mandatory
Voltage measured directly on the board in mV
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2544.1.3.1.2.1.8
metro1500DetailInfo mandatory
A Reference to the MIB Definition where the special
Options of the Component are described with more Details
ObjectIdentifier .1.3.6.1.4.1.2544.1.3.1.2.1.9
metro1500EPLDVersion mandatory
Software Version on the programmable Logic Circuit
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.2544.1.3.1.2.1.10

metro1500PSTable

table mandatory
.1.3.6.1.4.1.2544.1.3.1.3 · 1 row entry · 2 columns
Table of installed Power Supplies
metro1500PSEntry entry .1.3.6.1.4.1.2544.1.3.1.3.1
Installed METRO1500 Power Supplies
Indexes
metro1500PSNumber
Column Syntax OID
metro1500PSNumber mandatory
Number of installed Power Supply
Integer32
Constraints:
range: 1-32
.1.3.6.1.4.1.2544.1.3.1.3.1.1
metro1500PSOn mandatory
Is installed Power Supply On or Off
Enumeration
Enumerated Values:
1on
2off
.1.3.6.1.4.1.2544.1.3.1.3.1.2

metro1500FanTable

table mandatory
.1.3.6.1.4.1.2544.1.3.1.4 · 1 row entry · 2 columns
Table of installed Fans
metro1500FanEntry entry .1.3.6.1.4.1.2544.1.3.1.4.1
Installed METRO1500 Fans
Indexes
metro1500FanNumber
Column Syntax OID
metro1500FanNumber mandatory
Number of installed Fan
Integer32
Constraints:
range: 1-16
.1.3.6.1.4.1.2544.1.3.1.4.1.1
metro1500FanOn mandatory
Is installed Fan On or Off
Enumeration
Enumerated Values:
1on
2off
.1.3.6.1.4.1.2544.1.3.1.4.1.2
.1.3.6.1.4.1.2544.1.3.5.1 · 1 row entry · 15 columns
Table of installed METRO1500 Converters
metro1500ConverterEntry entry .1.3.6.1.4.1.2544.1.3.5.1.1
Installed METRO1500 Converters
Indexes
metro1500ConverterNumber
Column Syntax OID
metro1500ConverterNumber mandatory
Slot Number of installed Converter Card
Integer32
Constraints:
range: 1-79
.1.3.6.1.4.1.2544.1.3.5.1.1.1
metro1500RxLoc mandatory
Local Receiver has Signal (On) or Loss
of Signal (Off)
Enumeration
Enumerated Values:
1on
2off
.1.3.6.1.4.1.2544.1.3.5.1.1.2
metro1500TxLoc mandatory
Local Transmitter is On or Off
Enumeration
Enumerated Values:
1on
2off
3alwaysOn
4alwaysOff
.1.3.6.1.4.1.2544.1.3.5.1.1.3
metro1500TxLocC mandatory
Current of the local Transmitter in mA.
This Entry is only available if a Current Sensor is
installed
Integer32
Constraints:
range: 0-200
.1.3.6.1.4.1.2544.1.3.5.1.1.4
metro1500TxLocTemp mandatory
Temperature of the local Transmitter in Celsius.
This Entry is only available if the Laser is cooled
Integer32
Constraints:
range: -50-100
.1.3.6.1.4.1.2544.1.3.5.1.1.5
metro1500RxRem mandatory
Remote Receiver has Signal (On) or Loss
of Signal (Off)
Enumeration
Enumerated Values:
1on
2off
.1.3.6.1.4.1.2544.1.3.5.1.1.6
metro1500TxRem mandatory
Remote Transmitter is On or Off
Enumeration
Enumerated Values:
1on
2off
3alwaysOn
4alwaysOff
.1.3.6.1.4.1.2544.1.3.5.1.1.7
metro1500TxRemC mandatory
Current of the Remote Transmitter in Milli Ampere.
This Entry is only available if a Current Sensor is
installed
Integer32
Constraints:
range: 0-200
.1.3.6.1.4.1.2544.1.3.5.1.1.8
metro1500TxRemTemp mandatory
Temperature of the Remote Transmitter in Celsius
This Entry is only available if the Laser is cooled
Integer32
Constraints:
range: -50-100
.1.3.6.1.4.1.2544.1.3.5.1.1.9
metro1500RxRem2 mandatory
2nd Remote receiver has Signal (On) or Loss
of Signal (Off).
(Only available if a 2nd Remote Receiver is
installed)
Enumeration
Enumerated Values:
1on
2off
.1.3.6.1.4.1.2544.1.3.5.1.1.10
metro1500ClockState mandatory
Status of the Clock. This Entry is only available
if a Clock is installed. If the Clock is enabled,
and has an error output, and cannot synchronize to
the Signal, the Clock fails.
Enumeration
Enumerated Values:
1on
2off
3fail
.1.3.6.1.4.1.2544.1.3.5.1.1.11
metro1500ClockFreq mandatory
Frequency of the Clock in MBit/s. Only available if
a Clock is installed.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2544.1.3.5.1.1.12
metro1500LocLoop mandatory
Local Loop is set to On or to Off
Enumeration
Enumerated Values:
1on
2off
.1.3.6.1.4.1.2544.1.3.5.1.1.13
metro1500RemLoop mandatory
Remote Loop is set to On or to Off
Enumeration
Enumerated Values:
1on
2off
.1.3.6.1.4.1.2544.1.3.5.1.1.14
metro1500ClockType mandatory
Type of the Clock. Only available, if a Clock is installed.
Enumeration
Enumerated Values:
1multiClockLSModule
2multiClockLS
3multiClockFCGbE
5multiClockOCxGbE
7multiClockOCxFC
9multiClockOCxGbEFC
11multiClockFCGbEOnBoard
21fixedClock125MbpsModule
22fixedClock125Mbps
31fixedClock155MbpsModule
32fixedClock155Mbps
41fixedClock200MbpsModule
42fixedClock200Mbps
51fixedClock266MbpsModule
52fixedClock266Mbps
61fixedClock622MbpsModule
62fixedClock622Mbps
71fixedClock1062MbpsModule
72fixedClock1062Mbps
75fixedClock1250MbpsModule
76fixedClock1250Mbps
81fixedClock2500MbpsModule
82fixedClock2500Mbps
255other
.1.3.6.1.4.1.2544.1.3.5.1.1.15

metro1500SwitchTable

table mandatory
.1.3.6.1.4.1.2544.1.3.10.1 · 1 row entry · 6 columns
Table of installed METRO1500 Switches
metro1500SwitchEntry entry .1.3.6.1.4.1.2544.1.3.10.1.1
Installed METRO1500 Switches
Indexes
metro1500SwitchNumber
Column Syntax OID
metro1500SwitchNumber mandatory
Slot Number of installed Remote Optical Switch Card
Integer32
Constraints:
range: 1-79
.1.3.6.1.4.1.2544.1.3.10.1.1.1
metro1500SwitchLine mandatory
Active Line of Remote Optical Switch
Enumeration
Enumerated Values:
1lineA
2lineB
.1.3.6.1.4.1.2544.1.3.10.1.1.2
metro1500SwitchMode mandatory
Mode of Transmit Line of Remote Optical Switch
Enumeration
Enumerated Values:
1automatic
2locked
.1.3.6.1.4.1.2544.1.3.10.1.1.3
metro1500SwitchLaserOn mandatory
Shows if the reference Laser is On or Off
Enumeration
Enumerated Values:
1on
2off
.1.3.6.1.4.1.2544.1.3.10.1.1.4
metro1500SwitchLineAavail mandatory
Is Line A of Remote Optical Switch available?
Enumeration
Enumerated Values:
1available
2notAvailable
.1.3.6.1.4.1.2544.1.3.10.1.1.5
metro1500SwitchLineBavail mandatory
Is Line B of Remote Optical Switch available
Enumeration
Enumerated Values:
1available
2notAvailable
.1.3.6.1.4.1.2544.1.3.10.1.1.6
.1.3.6.1.4.1.2544.1.3.14.1 · 1 row entry · 21 columns
Table of installed FSP-II Hub Cards
metro1500EthernetHubEntry entry .1.3.6.1.4.1.2544.1.3.14.1.1
Installed FSP-II Hub Cards
Indexes
metro1500EthernetHubNumber
Column Syntax OID
metro1500EthernetHubNumber mandatory
Slot Number of installed Hub Card
Integer32
Constraints:
range: 1-79
.1.3.6.1.4.1.2544.1.3.14.1.1.1
metro1500EthernetHubPortEnable1 mandatory
is Hub Port 1 enabled ?
Enumeration
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.2544.1.3.14.1.1.10
metro1500EthernetHubPortPartitionStatus1 mandatory
is Port 1 partitioned ?
Enumeration
Enumerated Values:
1partitioned
2notPartitioned
.1.3.6.1.4.1.2544.1.3.14.1.1.11
metro1500EthernetHubPortLinkStatus1 mandatory
does Port 1 receive Link Pulses ?
Enumeration
Enumerated Values:
1linked
2notLinked
.1.3.6.1.4.1.2544.1.3.14.1.1.12
metro1500EthernetHubPortPolarity1 mandatory
polarity of input signal at Port 1
Enumeration
Enumerated Values:
1positive
2negative
.1.3.6.1.4.1.2544.1.3.14.1.1.13
metro1500EthernetHubPortEnable2 mandatory
is Hub Port 2 enabled ?
Enumeration
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.2544.1.3.14.1.1.20
metro1500EthernetHubPortPartitionStatus2 mandatory
is Port 2 partitioned ?
Enumeration
Enumerated Values:
1partitioned
2notPartitioned
.1.3.6.1.4.1.2544.1.3.14.1.1.21
metro1500EthernetHubPortLinkStatus2 mandatory
does Port 2 receive Link Pulses ?
Enumeration
Enumerated Values:
1linked
2notLinked
.1.3.6.1.4.1.2544.1.3.14.1.1.22
metro1500EthernetHubPortPolarity2 mandatory
polarity of input signal at Port 2
Enumeration
Enumerated Values:
1positive
2negative
.1.3.6.1.4.1.2544.1.3.14.1.1.23
metro1500EthernetHubPortEnable3 mandatory
is Hub Port 3 enabled ?
Enumeration
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.2544.1.3.14.1.1.30
metro1500EthernetHubPortPartitionStatus3 mandatory
is Port 3 partitioned ?
Enumeration
Enumerated Values:
1partitioned
2notPartitioned
.1.3.6.1.4.1.2544.1.3.14.1.1.31
metro1500EthernetHubPortLinkStatus3 mandatory
does Port 3 receive Link Pulses ?
Enumeration
Enumerated Values:
1linked
2notLinked
.1.3.6.1.4.1.2544.1.3.14.1.1.32
metro1500EthernetHubPortPolarity3 mandatory
polarity of input signal at Port 3
Enumeration
Enumerated Values:
1positive
2negative
.1.3.6.1.4.1.2544.1.3.14.1.1.33
metro1500EthernetHubPortEnable4 mandatory
is Hub Port 4 enabled ?
Enumeration
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.2544.1.3.14.1.1.40
metro1500EthernetHubPortPartitionStatus4 mandatory
is Port 4 partitioned ?
Enumeration
Enumerated Values:
1partitioned
2notPartitioned
.1.3.6.1.4.1.2544.1.3.14.1.1.41
metro1500EthernetHubPortLinkStatus4 mandatory
does Port 4 receive Link Pulses ?
Enumeration
Enumerated Values:
1linked
2notLinked
.1.3.6.1.4.1.2544.1.3.14.1.1.42
metro1500EthernetHubPortPolarity4 mandatory
polarity of input signal at Port 4
Enumeration
Enumerated Values:
1positive
2negative
.1.3.6.1.4.1.2544.1.3.14.1.1.43
metro1500EthernetHubPortEnable5 mandatory
is Hub Port 5 enabled ?
Enumeration
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.2544.1.3.14.1.1.50
metro1500EthernetHubPortPartitionStatus5 mandatory
is Port 5 partitioned ?
Enumeration
Enumerated Values:
1partitioned
2notPartitioned
.1.3.6.1.4.1.2544.1.3.14.1.1.51
metro1500EthernetHubPortLinkStatus5 mandatory
does Port 5 receive Link Pulses ?
Enumeration
Enumerated Values:
1linked
2notLinked
.1.3.6.1.4.1.2544.1.3.14.1.1.52
metro1500EthernetHubPortPolarity5 mandatory
polarity of input signal at Port 5
Enumeration
Enumerated Values:
1positive
2negative
.1.3.6.1.4.1.2544.1.3.14.1.1.53

metro1500TDMTable

table mandatory
.1.3.6.1.4.1.2544.1.3.15.1 · 1 row entry · 35 columns
Table of installed FSP-II TDM Cards
metro1500TDMEntry entry .1.3.6.1.4.1.2544.1.3.15.1.1
Installed FSP-II TDM Cards
Indexes
metro1500TDMNumber
Column Syntax OID
metro1500TDMNumber mandatory
Slot Number of installed TDM Card
Integer32
Constraints:
range: 1-79
.1.3.6.1.4.1.2544.1.3.15.1.1.1
metro1500TDMRxRem mandatory
Does the remote receiver receive Light (on) or not
(off)?
Enumeration
Enumerated Values:
1on
2off
.1.3.6.1.4.1.2544.1.3.15.1.1.4
metro1500TDMRxSync mandatory
Is the input signal synchronized with the corresponding
TDM card?
Enumeration
Enumerated Values:
1sync
2noSync
.1.3.6.1.4.1.2544.1.3.15.1.1.5
metro1500TDMTxRem mandatory
State of the Remote Transmitter
Enumeration
Enumerated Values:
1on
2off
3alwaysOn
4alwaysOff
.1.3.6.1.4.1.2544.1.3.15.1.1.6
metro1500TDMTxRemC mandatory
Current of the remote Transmitter in mA
Integer32
Constraints:
range: 0-200
.1.3.6.1.4.1.2544.1.3.15.1.1.7
metro1500TDMTxRemTemp mandatory
Temperature of the remote Transmitter in Celsius
Integer32
Constraints:
range: -50-100
.1.3.6.1.4.1.2544.1.3.15.1.1.8
metro1500TDMLocLoop mandatory
Loop for all Local Inputs enabled (on) or disabled (off)
Enumeration
Enumerated Values:
1on
2off
.1.3.6.1.4.1.2544.1.3.15.1.1.9
metro1500TDMLocModuleInst1 mandatory
is local Module 1 installed ?
Enumeration
Enumerated Values:
1installed
2notInstalled
.1.3.6.1.4.1.2544.1.3.15.1.1.20
metro1500TDMLocModuleEnable1 mandatory
is local Module 1 enabled ?
Enumeration
Enumerated Values:
1enabled
2notEnabled
.1.3.6.1.4.1.2544.1.3.15.1.1.21
metro1500TDMLocModuleRx1 mandatory
local receiver 1 gets signal (on)
Enumeration
Enumerated Values:
1on
2off
.1.3.6.1.4.1.2544.1.3.15.1.1.22
metro1500TDMLocModuleTx1 mandatory
state of the local transmitter
Enumeration
Enumerated Values:
1on
2off
3alwaysOn
4alwaysOff
.1.3.6.1.4.1.2544.1.3.15.1.1.23
metro1500TDMLocModuleRemoteData1 mandatory
receiving data for this module from the remote side
Enumeration
Enumerated Values:
1data
2noData
.1.3.6.1.4.1.2544.1.3.15.1.1.24
metro1500TDMLocModuleClockFrequency1 mandatory
data rate of the clock installed on local Module 1
in MBit/s
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2544.1.3.15.1.1.25
metro1500TDMLocModuleClockError1 mandatory
data rate and clock frequency are not synchronized
Enumeration
Enumerated Values:
1error
2noError
.1.3.6.1.4.1.2544.1.3.15.1.1.26
metro1500TDMLocModuleInst2 mandatory
is local Module 2 installed ?
Enumeration
Enumerated Values:
1installed
2notInstalled
.1.3.6.1.4.1.2544.1.3.15.1.1.30
metro1500TDMLocModuleEnable2 mandatory
is local Module 2 enabled ?
Enumeration
Enumerated Values:
1enabled
2notEnabled
.1.3.6.1.4.1.2544.1.3.15.1.1.31
metro1500TDMLocModuleRx2 mandatory
local receiver 2 gets signal (on)
Enumeration
Enumerated Values:
1on
2off
.1.3.6.1.4.1.2544.1.3.15.1.1.32
metro1500TDMLocModuleTx2 mandatory
state of the local transmitter
Enumeration
Enumerated Values:
1on
2off
3alwaysOn
4alwaysOff
.1.3.6.1.4.1.2544.1.3.15.1.1.33
metro1500TDMLocModuleRemoteData2 mandatory
receiving data for this module from the remote side
Enumeration
Enumerated Values:
1data
2noData
.1.3.6.1.4.1.2544.1.3.15.1.1.34
metro1500TDMLocModuleClockFrequency2 mandatory
data rate of the clock installed on local Module 2
in MBit/s
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2544.1.3.15.1.1.35
metro1500TDMLocModuleClockError2 mandatory
data rate and clock frequency are not synchronized
Enumeration
Enumerated Values:
1error
2noError
.1.3.6.1.4.1.2544.1.3.15.1.1.36
metro1500TDMLocModuleInst3 mandatory
is local Module 3 installed ?
Enumeration
Enumerated Values:
1installed
2notInstalled
.1.3.6.1.4.1.2544.1.3.15.1.1.40
metro1500TDMLocModuleEnable3 mandatory
is local Module 3 enabled ?
Enumeration
Enumerated Values:
1enabled
2notEnabled
.1.3.6.1.4.1.2544.1.3.15.1.1.41
metro1500TDMLocModuleRx3 mandatory
local receiver 3 gets signal (on)
Enumeration
Enumerated Values:
1on
2off
.1.3.6.1.4.1.2544.1.3.15.1.1.42
metro1500TDMLocModuleTx3 mandatory
state of the local transmitter
Enumeration
Enumerated Values:
1on
2off
3alwaysOn
4alwaysOff
.1.3.6.1.4.1.2544.1.3.15.1.1.43
metro1500TDMLocModuleRemoteData3 mandatory
receiving data for this module from the remote side
Enumeration
Enumerated Values:
1data
2noData
.1.3.6.1.4.1.2544.1.3.15.1.1.44
metro1500TDMLocModuleClockFrequency3 mandatory
data rate of the clock installed on local Module 3
in MBit/s
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2544.1.3.15.1.1.45
metro1500TDMLocModuleClockError3 mandatory
data rate and clock frequency are not synchronized
Enumeration
Enumerated Values:
1error
2noError
.1.3.6.1.4.1.2544.1.3.15.1.1.46
metro1500TDMLocModuleInst4 mandatory
is local Module 4 installed ?
Enumeration
Enumerated Values:
1installed
2notInstalled
.1.3.6.1.4.1.2544.1.3.15.1.1.50
metro1500TDMLocModuleEnable4 mandatory
is local Module 4 enabled ?
Enumeration
Enumerated Values:
1enabled
2notEnabled
.1.3.6.1.4.1.2544.1.3.15.1.1.51
metro1500TDMLocModuleRx4 mandatory
local receiver 4 gets signal (on)
Enumeration
Enumerated Values:
1on
2off
.1.3.6.1.4.1.2544.1.3.15.1.1.52
metro1500TDMLocModuleTx4 mandatory
state of the local transmitter
Enumeration
Enumerated Values:
1on
2off
3alwaysOn
4alwaysOff
.1.3.6.1.4.1.2544.1.3.15.1.1.53
metro1500TDMLocModuleRemoteData4 mandatory
receiving data for this module from the remote side
Enumeration
Enumerated Values:
1data
2noData
.1.3.6.1.4.1.2544.1.3.15.1.1.54
metro1500TDMLocModuleClockFrequency4 mandatory
data rate of the clock installed on local Module 4
in MBit/s
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2544.1.3.15.1.1.55
metro1500TDMLocModuleClockError4 mandatory
data rate and clock frequency are not synchronized
Enumeration
Enumerated Values:
1error