METRO1500-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
9
Rows
9
Columns
99
.1.3.6.1.4.1.2544.1.3.1.1.10
·
1 row entry
·
4 columns
Table of Trapsinks
Entries in the Trapsink Table
Indexes
metro1500MainTrapsinkNumber
| Column | Syntax | OID |
|---|---|---|
|
metro1500MainTrapsinkNumber
mandatory
Number of Trapsink
|
Integer32 Constraints: range: 1-10 |
.1.3.6.1.4.1.2544.1.3.1.1.10.1.1 |
|
metro1500MainTrapsinkAddress
mandatory
IP Address of the Management System which should receive SNMP
Traps. The Logfiles are also shown in this Table |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2544.1.3.1.1.10.1.2 |
|
metro1500MainTrapsinkCommunity
mandatory
Community String which is sent with a SNMP Trap to the
Management Station |
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2544.1.3.1.1.10.1.3 |
|
metro1500MainTrapsinkPriority
mandatory
Priority of the Trapsink (lower level gets less Traps)
|
Integer32 Constraints: range: 1-20 |
.1.3.6.1.4.1.2544.1.3.1.1.10.1.4 |
.1.3.6.1.4.1.2544.1.3.1.1.11
·
1 row entry
·
4 columns
Table of Log Files
Entries in the Logfile Table
Indexes
metro1500MainLogfileNumber
| Column | Syntax | OID |
|---|---|---|
|
metro1500MainLogfileNumber
mandatory
Number of Logfile
|
Integer32 Constraints: range: 1-2 |
.1.3.6.1.4.1.2544.1.3.1.1.11.1.1 |
|
metro1500MainLogfileName
mandatory
Name of Logfile
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2544.1.3.1.1.11.1.2 |
|
metro1500MainLogfileSize
mandatory
Size of Logfile
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2544.1.3.1.1.11.1.3 |
|
metro1500MainLogfilePriority
mandatory
Priority of Logfile
|
Integer32 Constraints: range: 1-20 |
.1.3.6.1.4.1.2544.1.3.1.1.11.1.4 |
.1.3.6.1.4.1.2544.1.3.1.2
·
1 row entry
·
10 columns
Table of installed METRO1500 Components. Since METRO1500 can handle many different Components, in this Section only the common Information is displayed. Component specific Information is stored in different Subtrees.
Installed METRO1500 Components
Indexes
metro1500SlotNumber
| Column | Syntax | OID | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
metro1500SlotNumber
mandatory
Slot Number of installed Component. The Device
Master has always Slot Number 0 and is shown in the Main section. |
Integer32 Constraints: range: 1-79 |
.1.3.6.1.4.1.2544.1.3.1.2.1.1 |
||||||||||||||||||||||
|
metro1500Type
mandatory
Type of installed Component
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2544.1.3.1.2.1.2 |
||||||||||||||||||||||
|
metro1500SlotTypeNumber
mandatory
Integer Number between 0 and 255 unique for a
specific type of installed Component. This Number can be used for management Systems to handle automatically the different Options of installed Components. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.1.2.1.3 |
||||||||||||||||||||||
|
metro1500SerialNumber
mandatory
Serial Number of installed Component
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2544.1.3.1.2.1.4 |
||||||||||||||||||||||
|
metro1500HardwareVersion
mandatory
Hardware Version of installed Component
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2544.1.3.1.2.1.5 |
||||||||||||||||||||||
|
metro1500SoftwareVersion
mandatory
SoftwareVersion of installed Component
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.2544.1.3.1.2.1.6 |
||||||||||||||||||||||
|
metro1500Temperature
mandatory
Temperature of installed Component in
Celsius |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2544.1.3.1.2.1.7 |
||||||||||||||||||||||
|
metro1500BoardVoltage
mandatory
Voltage measured directly on the board in mV
|
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2544.1.3.1.2.1.8 |
||||||||||||||||||||||
|
metro1500DetailInfo
mandatory
A Reference to the MIB Definition where the special
Options of the Component are described with more Details |
ObjectIdentifier | .1.3.6.1.4.1.2544.1.3.1.2.1.9 |
||||||||||||||||||||||
|
metro1500EPLDVersion
mandatory
Software Version on the programmable Logic Circuit
|
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.2544.1.3.1.2.1.10 |
.1.3.6.1.4.1.2544.1.3.1.3
·
1 row entry
·
2 columns
Table of installed Power Supplies
Installed METRO1500 Power Supplies
Indexes
metro1500PSNumber
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
metro1500PSNumber
mandatory
Number of installed Power Supply
|
Integer32 Constraints: range: 1-32 |
.1.3.6.1.4.1.2544.1.3.1.3.1.1 |
||||
|
metro1500PSOn
mandatory
Is installed Power Supply On or Off
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.1.3.1.2 |
.1.3.6.1.4.1.2544.1.3.1.4
·
1 row entry
·
2 columns
Table of installed Fans
Installed METRO1500 Fans
Indexes
metro1500FanNumber
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
metro1500FanNumber
mandatory
Number of installed Fan
|
Integer32 Constraints: range: 1-16 |
.1.3.6.1.4.1.2544.1.3.1.4.1.1 |
||||
|
metro1500FanOn
mandatory
Is installed Fan On or Off
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.1.4.1.2 |
.1.3.6.1.4.1.2544.1.3.5.1
·
1 row entry
·
15 columns
Table of installed METRO1500 Converters
Installed METRO1500 Converters
Indexes
metro1500ConverterNumber
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
metro1500ConverterNumber
mandatory
Slot Number of installed Converter Card
|
Integer32 Constraints: range: 1-79 |
.1.3.6.1.4.1.2544.1.3.5.1.1.1 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
metro1500RxLoc
mandatory
Local Receiver has Signal (On) or Loss
of Signal (Off) |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.5.1.1.2 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
metro1500TxLoc
mandatory
Local Transmitter is On or Off
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.5.1.1.3 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
metro1500TxLocC
mandatory
Current of the local Transmitter in mA.
This Entry is only available if a Current Sensor is installed |
Integer32 Constraints: range: 0-200 |
.1.3.6.1.4.1.2544.1.3.5.1.1.4 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
metro1500TxLocTemp
mandatory
Temperature of the local Transmitter in Celsius.
This Entry is only available if the Laser is cooled |
Integer32 Constraints: range: -50-100 |
.1.3.6.1.4.1.2544.1.3.5.1.1.5 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
metro1500RxRem
mandatory
Remote Receiver has Signal (On) or Loss
of Signal (Off) |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.5.1.1.6 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
metro1500TxRem
mandatory
Remote Transmitter is On or Off
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.5.1.1.7 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
metro1500TxRemC
mandatory
Current of the Remote Transmitter in Milli Ampere.
This Entry is only available if a Current Sensor is installed |
Integer32 Constraints: range: 0-200 |
.1.3.6.1.4.1.2544.1.3.5.1.1.8 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
metro1500TxRemTemp
mandatory
Temperature of the Remote Transmitter in Celsius
This Entry is only available if the Laser is cooled |
Integer32 Constraints: range: -50-100 |
.1.3.6.1.4.1.2544.1.3.5.1.1.9 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
metro1500RxRem2
mandatory
2nd Remote receiver has Signal (On) or Loss
of Signal (Off). (Only available if a 2nd Remote Receiver is installed) |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.5.1.1.10 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
metro1500ClockState
mandatory
Status of the Clock. This Entry is only available
if a Clock is installed. If the Clock is enabled, and has an error output, and cannot synchronize to the Signal, the Clock fails. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.5.1.1.11 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
metro1500ClockFreq
mandatory
Frequency of the Clock in MBit/s. Only available if
a Clock is installed. |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2544.1.3.5.1.1.12 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
metro1500LocLoop
mandatory
Local Loop is set to On or to Off
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.5.1.1.13 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
metro1500RemLoop
mandatory
Remote Loop is set to On or to Off
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.5.1.1.14 |
||||||||||||||||||||||||||||||||||||||||||||||||
|
metro1500ClockType
mandatory
Type of the Clock. Only available, if a Clock is installed.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.5.1.1.15 |
.1.3.6.1.4.1.2544.1.3.10.1
·
1 row entry
·
6 columns
Table of installed METRO1500 Switches
Installed METRO1500 Switches
Indexes
metro1500SwitchNumber
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
metro1500SwitchNumber
mandatory
Slot Number of installed Remote Optical Switch Card
|
Integer32 Constraints: range: 1-79 |
.1.3.6.1.4.1.2544.1.3.10.1.1.1 |
||||
|
metro1500SwitchLine
mandatory
Active Line of Remote Optical Switch
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.10.1.1.2 |
||||
|
metro1500SwitchMode
mandatory
Mode of Transmit Line of Remote Optical Switch
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.10.1.1.3 |
||||
|
metro1500SwitchLaserOn
mandatory
Shows if the reference Laser is On or Off
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.10.1.1.4 |
||||
|
metro1500SwitchLineAavail
mandatory
Is Line A of Remote Optical Switch available?
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.10.1.1.5 |
||||
|
metro1500SwitchLineBavail
mandatory
Is Line B of Remote Optical Switch available
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.10.1.1.6 |
.1.3.6.1.4.1.2544.1.3.14.1
·
1 row entry
·
21 columns
Table of installed FSP-II Hub Cards
Installed FSP-II Hub Cards
Indexes
metro1500EthernetHubNumber
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
metro1500EthernetHubNumber
mandatory
Slot Number of installed Hub Card
|
Integer32 Constraints: range: 1-79 |
.1.3.6.1.4.1.2544.1.3.14.1.1.1 |
||||
|
metro1500EthernetHubPortEnable1
mandatory
is Hub Port 1 enabled ?
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.14.1.1.10 |
||||
|
metro1500EthernetHubPortPartitionStatus1
mandatory
is Port 1 partitioned ?
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.14.1.1.11 |
||||
|
metro1500EthernetHubPortLinkStatus1
mandatory
does Port 1 receive Link Pulses ?
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.14.1.1.12 |
||||
|
metro1500EthernetHubPortPolarity1
mandatory
polarity of input signal at Port 1
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.14.1.1.13 |
||||
|
metro1500EthernetHubPortEnable2
mandatory
is Hub Port 2 enabled ?
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.14.1.1.20 |
||||
|
metro1500EthernetHubPortPartitionStatus2
mandatory
is Port 2 partitioned ?
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.14.1.1.21 |
||||
|
metro1500EthernetHubPortLinkStatus2
mandatory
does Port 2 receive Link Pulses ?
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.14.1.1.22 |
||||
|
metro1500EthernetHubPortPolarity2
mandatory
polarity of input signal at Port 2
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.14.1.1.23 |
||||
|
metro1500EthernetHubPortEnable3
mandatory
is Hub Port 3 enabled ?
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.14.1.1.30 |
||||
|
metro1500EthernetHubPortPartitionStatus3
mandatory
is Port 3 partitioned ?
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.14.1.1.31 |
||||
|
metro1500EthernetHubPortLinkStatus3
mandatory
does Port 3 receive Link Pulses ?
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.14.1.1.32 |
||||
|
metro1500EthernetHubPortPolarity3
mandatory
polarity of input signal at Port 3
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.14.1.1.33 |
||||
|
metro1500EthernetHubPortEnable4
mandatory
is Hub Port 4 enabled ?
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.14.1.1.40 |
||||
|
metro1500EthernetHubPortPartitionStatus4
mandatory
is Port 4 partitioned ?
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.14.1.1.41 |
||||
|
metro1500EthernetHubPortLinkStatus4
mandatory
does Port 4 receive Link Pulses ?
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.14.1.1.42 |
||||
|
metro1500EthernetHubPortPolarity4
mandatory
polarity of input signal at Port 4
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.14.1.1.43 |
||||
|
metro1500EthernetHubPortEnable5
mandatory
is Hub Port 5 enabled ?
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.14.1.1.50 |
||||
|
metro1500EthernetHubPortPartitionStatus5
mandatory
is Port 5 partitioned ?
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.14.1.1.51 |
||||
|
metro1500EthernetHubPortLinkStatus5
mandatory
does Port 5 receive Link Pulses ?
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.14.1.1.52 |
||||
|
metro1500EthernetHubPortPolarity5
mandatory
polarity of input signal at Port 5
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.14.1.1.53 |
.1.3.6.1.4.1.2544.1.3.15.1
·
1 row entry
·
35 columns
Table of installed FSP-II TDM Cards
Installed FSP-II TDM Cards
Indexes
metro1500TDMNumber
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
metro1500TDMNumber
mandatory
Slot Number of installed TDM Card
|
Integer32 Constraints: range: 1-79 |
.1.3.6.1.4.1.2544.1.3.15.1.1.1 |
||||||||
|
metro1500TDMRxRem
mandatory
Does the remote receiver receive Light (on) or not
(off)? |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.15.1.1.4 |
||||||||
|
metro1500TDMRxSync
mandatory
Is the input signal synchronized with the corresponding
TDM card? |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.15.1.1.5 |
||||||||
|
metro1500TDMTxRem
mandatory
State of the Remote Transmitter
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.15.1.1.6 |
||||||||
|
metro1500TDMTxRemC
mandatory
Current of the remote Transmitter in mA
|
Integer32 Constraints: range: 0-200 |
.1.3.6.1.4.1.2544.1.3.15.1.1.7 |
||||||||
|
metro1500TDMTxRemTemp
mandatory
Temperature of the remote Transmitter in Celsius
|
Integer32 Constraints: range: -50-100 |
.1.3.6.1.4.1.2544.1.3.15.1.1.8 |
||||||||
|
metro1500TDMLocLoop
mandatory
Loop for all Local Inputs enabled (on) or disabled (off)
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.15.1.1.9 |
||||||||
|
metro1500TDMLocModuleInst1
mandatory
is local Module 1 installed ?
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.15.1.1.20 |
||||||||
|
metro1500TDMLocModuleEnable1
mandatory
is local Module 1 enabled ?
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.15.1.1.21 |
||||||||
|
metro1500TDMLocModuleRx1
mandatory
local receiver 1 gets signal (on)
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.15.1.1.22 |
||||||||
|
metro1500TDMLocModuleTx1
mandatory
state of the local transmitter
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.15.1.1.23 |
||||||||
|
metro1500TDMLocModuleRemoteData1
mandatory
receiving data for this module from the remote side
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.15.1.1.24 |
||||||||
|
metro1500TDMLocModuleClockFrequency1
mandatory
data rate of the clock installed on local Module 1
in MBit/s |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2544.1.3.15.1.1.25 |
||||||||
|
metro1500TDMLocModuleClockError1
mandatory
data rate and clock frequency are not synchronized
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.15.1.1.26 |
||||||||
|
metro1500TDMLocModuleInst2
mandatory
is local Module 2 installed ?
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.15.1.1.30 |
||||||||
|
metro1500TDMLocModuleEnable2
mandatory
is local Module 2 enabled ?
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.15.1.1.31 |
||||||||
|
metro1500TDMLocModuleRx2
mandatory
local receiver 2 gets signal (on)
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.15.1.1.32 |
||||||||
|
metro1500TDMLocModuleTx2
mandatory
state of the local transmitter
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.15.1.1.33 |
||||||||
|
metro1500TDMLocModuleRemoteData2
mandatory
receiving data for this module from the remote side
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.15.1.1.34 |
||||||||
|
metro1500TDMLocModuleClockFrequency2
mandatory
data rate of the clock installed on local Module 2
in MBit/s |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2544.1.3.15.1.1.35 |
||||||||
|
metro1500TDMLocModuleClockError2
mandatory
data rate and clock frequency are not synchronized
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.15.1.1.36 |
||||||||
|
metro1500TDMLocModuleInst3
mandatory
is local Module 3 installed ?
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.15.1.1.40 |
||||||||
|
metro1500TDMLocModuleEnable3
mandatory
is local Module 3 enabled ?
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.15.1.1.41 |
||||||||
|
metro1500TDMLocModuleRx3
mandatory
local receiver 3 gets signal (on)
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.15.1.1.42 |
||||||||
|
metro1500TDMLocModuleTx3
mandatory
state of the local transmitter
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.15.1.1.43 |
||||||||
|
metro1500TDMLocModuleRemoteData3
mandatory
receiving data for this module from the remote side
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.15.1.1.44 |
||||||||
|
metro1500TDMLocModuleClockFrequency3
mandatory
data rate of the clock installed on local Module 3
in MBit/s |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2544.1.3.15.1.1.45 |
||||||||
|
metro1500TDMLocModuleClockError3
mandatory
data rate and clock frequency are not synchronized
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.15.1.1.46 |
||||||||
|
metro1500TDMLocModuleInst4
mandatory
is local Module 4 installed ?
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.15.1.1.50 |
||||||||
|
metro1500TDMLocModuleEnable4
mandatory
is local Module 4 enabled ?
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.15.1.1.51 |
||||||||
|
metro1500TDMLocModuleRx4
mandatory
local receiver 4 gets signal (on)
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.15.1.1.52 |
||||||||
|
metro1500TDMLocModuleTx4
mandatory
state of the local transmitter
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.15.1.1.53 |
||||||||
|
metro1500TDMLocModuleRemoteData4
mandatory
receiving data for this module from the remote side
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.15.1.1.54 |
||||||||
|
metro1500TDMLocModuleClockFrequency4
mandatory
data rate of the clock installed on local Module 4
in MBit/s |
Integer32 Textual Convention: COPS-PR-SPPIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2544.1.3.15.1.1.55 |
||||||||
|
metro1500TDMLocModuleClockError4
mandatory
data rate and clock frequency are not synchronized
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2544.1.3.15.1.1.56 |