LHX-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
4
Rows
4
Columns
30
.1.3.6.1.4.1.13742.9.1.2 · 1 row entry · 1 columns
A list of lhx sensor count extries.
sensorCountEntry entry .1.3.6.1.4.1.13742.9.1.2.1
An entry containing the number of lhx sensors of a certain type.
Indexes
portIdx sensorTypeIdx
Column Syntax OID
sensorCount
The number of sensors.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.13742.9.1.2.1.1
.1.3.6.1.4.1.13742.9.1.3.1 · 1 row entry · 8 columns
A list of lhx controller configuration extries.
The number of entries is given by the value of portCount.
lhxConfigurationEntry entry .1.3.6.1.4.1.13742.9.1.3.1.1
An entry containing parameters for an lhx.
Indexes
portIdx
Column Syntax OID
operationalState
The operational state of the lhx controller.
To switch LHX power state while controller is connected,
set operationalState to 1 (off) or 2 (on).
Switching power state while LHX is disconnected or to
0 (disconnected) is…
OperationalStateEnumerationr/w
Textual Convention: OperationalStateEnumeration Enumeration
Type Values:
0disconnected
1offline
2online
.1.3.6.1.4.1.13742.9.1.3.1.1.1
setpointVentilators
The setpoint of the ventilators.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.13742.9.1.3.1.1.2
setpointWaterValve
The setpoint of the water valve.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.13742.9.1.3.1.1.3
defaultFanSpeed
The 'default' fan speed during normal operation in per mill.
Default is 80% (= 800).
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.13742.9.1.3.1.1.4
maximumCoolingState
Indicates whether maximum cooling was requested or not.
To request maximum cooling, set maximumCoolingState to 1 (true).
Setting maximumCoolingState to 2 (false) is undefined,
set alertState to 2 (false) instead.
SNMPv2-TCTruthValuer/w
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.13742.9.1.3.1.1.5
alertState
Indicates whether LHX controler is in alert state or not.
To acknowledge alert status, set alertState to 2 (false).
Setting alertState to 1 (true) is undefined.
SNMPv2-TCTruthValuer/w
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.13742.9.1.3.1.1.6
model
The model indentifier of an LHX controller.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.13742.9.1.3.1.1.7
fwVersion
The firmware version of an LHX controller.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.13742.9.1.3.1.1.8
.1.3.6.1.4.1.13742.9.1.4.1 · 1 row entry · 17 columns
A list of lhx sensor configuration extries.
The number of entries is given by the value of portCount.
sensorConfigurationEntry entry .1.3.6.1.4.1.13742.9.1.4.1.1
An entry containing parameters for an lhx.
Indexes
portIdx sensorTypeIdx sensorIdx
Column Syntax OID
portIdx
A unique value for each port. Its value
ranges between 1 and the value of portCount.
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.13742.9.1.4.1.1.1
sensorTypeIdx
A unique value for the type of sensor.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.13742.9.1.4.1.1.2
sensorIdx
A unique value for each sensor. Its value
ranges between 1 and the value of sensorCount.
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.13742.9.1.4.1.1.3
sensorLabel
The short ID of the sensor (e.g. F1, M2).
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.13742.9.1.4.1.1.4
sensorUnit
The base units.
This parameter does not apply to state sensors.
SensorUnitsEnumeration
Textual Convention: SensorUnitsEnumeration Enumeration
Type Values:
-1none
0other
1volt
2amp
3watt
4voltamp
5wattHour
6voltampHour
7degreeC
8hertz
9percent
10meterpersec
11pascal
12psi
13g
14degreeF
15feet
16inches
17cm
18meters
19rpm
.1.3.6.1.4.1.13742.9.1.4.1.1.5
sensorDecimalDigits
The number of digits displayed to the right of the decimal point.
This parameter does not apply to state sensors.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.13742.9.1.4.1.1.6
sensorMaximum
The largest possible value.
The value of this OID variable should be scaled by
sensorDecimalDigits. For example, if the value is 1 and
sensorDecimalDigits is 2, then actual value is 0.01.
This parameter does not apply …
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.13742.9.1.4.1.1.7
sensorMinimum
The smallest possible value.
The value of this OID variable should be scaled by
sensorDecimalDigits. For example, if the value is 1 and
sensorDecimalDigits is 2, then actual value is 0.01.
This parameter does not apply…
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.13742.9.1.4.1.1.8
sensorHysteresis
The hysteresis used for deassertions.
The value of this OID variable should be scaled by
sensorDecimalDigits. For example, if the value is 1 and
sensorDecimalDigits is 2, then actual value is 0.01.
This parameter does …
SNMPv2-SMIUnsigned32r/w
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.13742.9.1.4.1.1.9
sensorLowerCriticalThreshold
The lower critical threshold.
The value of this OID variable should be scaled by
sensorDecimalDigits. For example, if the value is 1 and
sensorDecimalDigits is 2, then actual value is 0.01.
This parameter does not appl…
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.13742.9.1.4.1.1.10
sensorLowerWarningThreshold
The lower non-critical (warning) threshold.
The value of this OID variable should be scaled by
sensorDecimalDigits. For example, if the value is 1 and
sensorDecimalDigits is 2, then actual value is 0.01.
This parameter…
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.13742.9.1.4.1.1.11
sensorUpperCriticalThreshold
The upper critical threshold.
The value of this OID variable should be scaled by
sensorDecimalDigits. For example, if the value is 1 and
sensorDecimalDigits is 2, then actual value is 0.01.
This parameter does not app…
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.13742.9.1.4.1.1.12
sensorUpperWarningThreshold
The upper non-critical (warning) threshold.
The value of this OID variable should be scaled by
sensorDecimalDigits. For example, if the value is 1 and
sensorDecimalDigits is 2, then actual value is 0.01.
This parameter…
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.13742.9.1.4.1.1.13
sensorEnabledThresholds
A bit string which indicates which thresholds are enabled.
This parameter does not apply to state sensors.
Bitsr/w
Enumerated Values:
0lowerCritical
1lowerWarning
2upperWarning
3upperCritical
.1.3.6.1.4.1.13742.9.1.4.1.1.14
sensorThresholdMaximum
The largest possible threshold value.
The value of this OID variable should be scaled by
sensorDecimalDigits. For example, if the value is 1 and
sensorDecimalDigits is 2, then actual value is 0.01.
This parameter does …
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.13742.9.1.4.1.1.15
sensorThresholdMinimum
The smallest possible threshold value.
The value of this OID variable should be scaled by
sensorDecimalDigits. For example, if the value is 1 and
sensorDecimalDigits is 2, then actual value is 0.01.
This parameter does…
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.13742.9.1.4.1.1.16
sensorName
The descriptive ID of the sensor (e.g. Fan Speed 1).
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.13742.9.1.4.1.1.17
.1.3.6.1.4.1.13742.9.2.1 · 1 row entry · 4 columns
A list of external sensor entries. The number of
entries is given by the value of sensorCount
for the LHX.
sensorMeasurementsEntry entry .1.3.6.1.4.1.13742.9.2.1.1
An entry containing measurement objects for an external sensor.
Indexes
portIdx sensorTypeIdx sensorIdx
Column Syntax OID
measurementsSensorIsAvailable
Is the sensor available?
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.13742.9.2.1.1.1
measurementsSensorState
The sensor state.
SensorStateEnumeration
Textual Convention: SensorStateEnumeration Enumeration
Type Values:
-1unavailable
0open
1closed
2belowLowerCritical
3belowLowerWarning
4normal
5aboveUpperWarning
6aboveUpperCritical
7on
8off
9detected
10notDetected
11alarmed
.1.3.6.1.4.1.13742.9.2.1.1.2
measurementsSensorValue
The sensor reading.
This parameter does not apply to state sensors.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.13742.9.2.1.1.3
measurementsSensorTimeStamp
The sensor reading timestamp.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.13742.9.2.1.1.4