H3C-STORAGE-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
5
Rows
5
Columns
26
.1.3.6.1.4.1.2011.10.10.1.1.2.1 · 1 row entry · 3 columns
This table contains some information of a particular DEU(Disk Enclosure
Unit).
h3cDeuEntry entry .1.3.6.1.4.1.2011.10.10.1.1.2.1.1
An entry containing management information applicable
to a particular DEU.
Indexes
h3cDeuIndex
Column Syntax OID
h3cDeuIndex
This object identifies the index of h3cDeuTable. The DEU identified
by a particular value of this index is the same object as identified
by the same value of entPhysicalIndex.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.10.10.1.1.2.1.1.1
h3cDeuIDLed
This object identifies the state of storage DEU's led.
H3C-STORAGE-REF-MIBH3cStorageLedStateTyper/w
Textual Convention: H3C-STORAGE-REF-MIBH3cStorageLedStateType Enumeration
Type Values:
1off
2on
3blink
.1.3.6.1.4.1.2011.10.10.1.1.2.1.1.2
h3cDeuDiskScan
The operation of scanning the table. When the value of this object
is set to 'action', the operation of disk scanning is touched off.
H3C-STORAGE-REF-MIBH3cStorageActionTyper/w
Textual Convention: H3C-STORAGE-REF-MIBH3cStorageActionType Enumeration
Type Values:
1action
2invalid
.1.3.6.1.4.1.2011.10.10.1.1.2.1.1.3
.1.3.6.1.4.1.2011.10.10.1.1.2.2 · 1 row entry · 4 columns
This table describes the interface information of the network.
h3cStorageInterfaceEntry entry .1.3.6.1.4.1.2011.10.10.1.1.2.2.1
An entry containing management information applicable
to a particular interface.
Indexes
h3cStorageInterfaceIndex
Column Syntax OID
h3cStorageInterfaceIndex
This object identifies the index of H3cStorageInterfaceEntry. The
interface identified by this index is the same interface as identified
by the same value of ifIndex.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.10.10.1.1.2.2.1.1
h3cStorageInterfaceGateway
This object identifies the gateway address of interface.
INET-ADDRESS-MIBInetAddressr/w
Textual Convention: INET-ADDRESS-MIBInetAddress OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.2011.10.10.1.1.2.2.1.2
h3cStorageInterfaceGatewayType
This object identifies the gateway address type of interface.
INET-ADDRESS-MIBInetAddressTyper/w
Textual Convention: INET-ADDRESS-MIBInetAddressType Enumeration
Type Values:
0unknown
1ipv4
2ipv6
3ipv4z
4ipv6z
16dns
25l2vpn
.1.3.6.1.4.1.2011.10.10.1.1.2.2.1.3
h3cStorageInterfaceMTU
This object identifies the MTU of interface.
Enumerationr/w
Enumerated Values:
1500mtu1
9000mtu2
.1.3.6.1.4.1.2011.10.10.1.1.2.2.1.4
.1.3.6.1.4.1.2011.10.10.1.1.2.3 · 1 row entry · 2 columns
This table describes the information of the Bonding interface.
h3cBondingEntry entry .1.3.6.1.4.1.2011.10.10.1.1.2.3.1
An entry containing management information applicable to a particular
Bonding interface.
Indexes
h3cBondingIndex
Column Syntax OID
h3cBondingIndex
This object identifies the index of h3cBondingEntry. The interface
identified by this index is the same interface as identified by the
same value of ifIndex.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.10.10.1.1.2.3.1.1
h3cBondingPortList
An entry contains management information applicable to a particular bonding interface.
Every two bytes describe the ifIndex of an interface, and an interface belongs
to one bonding group only. An interface should be del…
OctetStringr/w .1.3.6.1.4.1.2011.10.10.1.1.2.3.1.2
.1.3.6.1.4.1.2011.10.10.1.1.2.4 · 1 row entry · 8 columns
This table containing some information of the SCSI(Small Computer
System interface) adapter.
h3cScsiAdapterEntry entry .1.3.6.1.4.1.2011.10.10.1.1.2.4.1
An entry containing management information applicable
to a particular SCSI adapter.
Indexes
ENTITY-MIBentPhysicalIndex h3cAdapterNumber
Column Syntax OID
h3cAdapterNumber
This object identifies the index of the adapter .
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.10.10.1.1.2.4.1.1
h3cAdapterDesc
This object describes some information of the adapter.
OctetString .1.3.6.1.4.1.2011.10.10.1.1.2.4.1.2
h3cAdapterType
This object identifies the type of adapter. If the value of this
object is not equal to 'fc', the associated object(such as h3cFcAdapterMode,
h3cFcAdapterIWWPNs,h3cFcAdapterTWWPNs,h3cFcAdapterPortState,h3cFcAdapterModeS…
Enumeration
Enumerated Values:
1scsi
2fc
.1.3.6.1.4.1.2011.10.10.1.1.2.4.1.3
h3cFcAdapterMode
This object identifies the mode type of adapter.
Enumeration
Enumerated Values:
1initiator
2target
3dual
.1.3.6.1.4.1.2011.10.10.1.1.2.4.1.4
h3cFcAdapterInitiatorWwpnName
This object describes the FC's adapter WWPN(World Wide Port
Name) numbers.
H3C-STORAGE-REF-MIBH3cWwpnListType
Textual Convention: H3C-STORAGE-REF-MIBH3cWwpnListType OctetString
.1.3.6.1.4.1.2011.10.10.1.1.2.4.1.5
h3cFcAdapterTargetWwpnName
This object describes the FC's target WWPN numbers.
H3C-STORAGE-REF-MIBH3cWwpnListType
Textual Convention: H3C-STORAGE-REF-MIBH3cWwpnListType OctetString
.1.3.6.1.4.1.2011.10.10.1.1.2.4.1.6
h3cFcAdapterPortState
This object identifies the state of adapter's interface.
Enumeration
Enumerated Values:
1linkup
2linkdown
.1.3.6.1.4.1.2011.10.10.1.1.2.4.1.7
h3cFcAdapterModeSwitch
This object identifies if the adapter work on a target mode.
H3C-STORAGE-REF-MIBH3cStorageEnableStater/w
Textual Convention: H3C-STORAGE-REF-MIBH3cStorageEnableState Enumeration
Type Values:
1enable
2disable
.1.3.6.1.4.1.2011.10.10.1.1.2.4.1.8
.1.3.6.1.4.1.2011.10.10.1.1.2.5 · 1 row entry · 9 columns
This table contains some entity extend information of the voltage.
h3cExtVoltageEntry entry .1.3.6.1.4.1.2011.10.10.1.1.2.5.1
An entry containing management information applicable to the voltage.
Indexes
h3cExtVoltagePhysicalIndex
Column Syntax OID
h3cExtVoltagePhysicalIndex
This object identifies the entity index of voltage.
ENTITY-MIBPhysicalIndex
Textual Convention: ENTITY-MIBPhysicalIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.2011.10.10.1.1.2.5.1.1
h3cExtVoltagePhysicalName
This object identifies the entity name of voltage.
SNMP-FRAMEWORK-MIBSnmpAdminString
Textual Convention: SNMP-FRAMEWORK-MIBSnmpAdminString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.2011.10.10.1.1.2.5.1.2
h3cExtVoltage
The voltage for the entity.
SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.10.10.1.1.2.5.1.3
h3cExtVoltageLowThreshold
The low-threshold for the voltage.
When voltage is lower than low-threshold, a notification will be
sent.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.10.10.1.1.2.5.1.4
h3cExtVoltageHighThreshold
The high-threshold for the voltage.
When voltage is higher than high-threshold, a notification will be
sent.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.10.10.1.1.2.5.1.5
h3cExtCriticalVoltageLowThreshold
The critical low threshold for voltage.
If the voltage is lower too much than the entity needs,
the entity will halt.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.10.10.1.1.2.5.1.6
h3cExtCriticalVoltageHighThreshold
The critical high threshold for voltage.
If the voltage is higher too much than the entity needs,
the entity will halt.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.10.10.1.1.2.5.1.7
h3cExtShutdownVoltageLowThreshold
The voltage is lower than the critical low threshold.
If the voltage is lower too much than the entity needs,
the entity halts now.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.10.10.1.1.2.5.1.8
h3cExtShutdownVoltageHighThreshold
The voltage is higher than the critical high threshold.
If the voltage is higher too much than the entity needs,
the entity halts now.
SNMPv2-SMIInteger32r/w
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.2011.10.10.1.1.2.5.1.9