H3C-STORAGE-MIB

        This MIB describes the general information of storage device,
such as the property, configuration and management.
    
h3cStorageMIB 1.3.6.1.4.1.2011.10.10.1
Imported Objects
ENTITY-MIB entPhysicalDescr entPhysicalIndex entPhysicalName PhysicalIndex
H3C-DISK-MIB h3cDiskPowerOffReason
H3C-ENTITY-EXT-MIB h3cEntityExtCriticalLowerTemperatureThreshold h3cEntityExtOperStatus h3cEntityExtPhysicalIndex h3cEntityExtShutdownLowerTemperatureThreshold h3cEntityExtTemperature
H3C-RAID-MIB h3cRaidHideState h3cRaidName h3cRaidRunState h3cRaidUuid
H3C-STORAGE-REF-MIB H3cSoftwareInfoString H3cStorageActionType H3cStorageCapableState H3cStorageEnableState H3cStorageLedStateType h3cStorageRef H3cWwpnListType
INET-ADDRESS-MIB InetAddress InetAddressType
SNMP-FRAMEWORK-MIB SnmpAdminString
SNMPv2-SMI Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE
Objects (63)
h3cStorageMIB .1.3.6.1.4.1.2011.10.10.1
h3cStorageMibObjects .1.3.6.1.4.1.2011.10.10.1.1
h3cStorageServerInfo .1.3.6.1.4.1.2011.10.10.1.1.1
h3cStorageServerCapability .1.3.6.1.4.1.2011.10.10.1.1.1.1
h3cRaidCapability H3C-STORAGE-REF-MIBH3cStorageCapableState .1.3.6.1.4.1.2011.10.10.1.1.1.1.1
h3cSseCapability H3C-STORAGE-REF-MIBH3cStorageCapableState .1.3.6.1.4.1.2011.10.10.1.1.1.1.10
h3cFcCapability H3C-STORAGE-REF-MIBH3cStorageCapableState .1.3.6.1.4.1.2011.10.10.1.1.1.1.2
h3cNasCapability H3C-STORAGE-REF-MIBH3cStorageCapableState .1.3.6.1.4.1.2011.10.10.1.1.1.1.3
h3cAdaptiveRepCapability H3C-STORAGE-REF-MIBH3cStorageCapableState .1.3.6.1.4.1.2011.10.10.1.1.1.1.4
h3cRemoteRepCapability H3C-STORAGE-REF-MIBH3cStorageCapableState .1.3.6.1.4.1.2011.10.10.1.1.1.1.5
h3cSafeCacheCapability H3C-STORAGE-REF-MIBH3cStorageCapableState .1.3.6.1.4.1.2011.10.10.1.1.1.1.6
h3cSyncMirrorCapability H3C-STORAGE-REF-MIBH3cStorageCapableState .1.3.6.1.4.1.2011.10.10.1.1.1.1.7
h3cAsyncMirrorCapability H3C-STORAGE-REF-MIBH3cStorageCapableState .1.3.6.1.4.1.2011.10.10.1.1.1.1.8
h3cTimeMarkCapability H3C-STORAGE-REF-MIBH3cStorageCapableState .1.3.6.1.4.1.2011.10.10.1.1.1.1.9
h3cStorageTargetConfig .1.3.6.1.4.1.2011.10.10.1.1.1.2
h3ciSCSITargetEnable r/w H3C-STORAGE-REF-MIBH3cStorageEnableState .1.3.6.1.4.1.2011.10.10.1.1.1.2.1
h3cFcTargetEnable r/w H3C-STORAGE-REF-MIBH3cStorageEnableState .1.3.6.1.4.1.2011.10.10.1.1.1.2.2
h3cStorageServerPhysInfo .1.3.6.1.4.1.2011.10.10.1.1.1.3
h3cServerLocationLedState r/w H3C-STORAGE-REF-MIBH3cStorageLedStateType .1.3.6.1.4.1.2011.10.10.1.1.1.3.1
h3cServerResetButtonState r/w H3C-STORAGE-REF-MIBH3cStorageEnableState .1.3.6.1.4.1.2011.10.10.1.1.1.3.2
h3cServerPowerButtonState r/w H3C-STORAGE-REF-MIBH3cStorageEnableState .1.3.6.1.4.1.2011.10.10.1.1.1.3.3
h3cServerPowerState Enumeration .1.3.6.1.4.1.2011.10.10.1.1.1.3.4
h3cStoragePhysicalInfo .1.3.6.1.4.1.2011.10.10.1.1.2
h3cDeuTable .1.3.6.1.4.1.2011.10.10.1.1.2.1
h3cDeuEntry h3cDeuIndex .1.3.6.1.4.1.2011.10.10.1.1.2.1.1
h3cDeuIndex Integer32 .1.3.6.1.4.1.2011.10.10.1.1.2.1.1.1
h3cDeuIDLed r/w H3C-STORAGE-REF-MIBH3cStorageLedStateType .1.3.6.1.4.1.2011.10.10.1.1.2.1.1.2
h3cDeuDiskScan r/w H3C-STORAGE-REF-MIBH3cStorageActionType .1.3.6.1.4.1.2011.10.10.1.1.2.1.1.3
h3cStorageInterfaceTable .1.3.6.1.4.1.2011.10.10.1.1.2.2
h3cStorageInterfaceEntry h3cStorageInterfaceIndex .1.3.6.1.4.1.2011.10.10.1.1.2.2.1
h3cStorageInterfaceIndex Integer32 .1.3.6.1.4.1.2011.10.10.1.1.2.2.1.1
h3cStorageInterfaceGateway r/w INET-ADDRESS-MIBInetAddress .1.3.6.1.4.1.2011.10.10.1.1.2.2.1.2
h3cStorageInterfaceGatewayType r/w INET-ADDRESS-MIBInetAddressType .1.3.6.1.4.1.2011.10.10.1.1.2.2.1.3
h3cStorageInterfaceMTU r/w Enumeration .1.3.6.1.4.1.2011.10.10.1.1.2.2.1.4
h3cBondingTable .1.3.6.1.4.1.2011.10.10.1.1.2.3
h3cBondingEntry h3cBondingIndex .1.3.6.1.4.1.2011.10.10.1.1.2.3.1
h3cBondingIndex Integer32 .1.3.6.1.4.1.2011.10.10.1.1.2.3.1.1
h3cBondingPortList r/w OctetString .1.3.6.1.4.1.2011.10.10.1.1.2.3.1.2
h3cScsiAdapterTable .1.3.6.1.4.1.2011.10.10.1.1.2.4
h3cScsiAdapterEntry ENTITY-MIBentPhysicalIndexh3cAdapterNumber .1.3.6.1.4.1.2011.10.10.1.1.2.4.1
h3cAdapterNumber Integer32 .1.3.6.1.4.1.2011.10.10.1.1.2.4.1.1
h3cAdapterDesc OctetString .1.3.6.1.4.1.2011.10.10.1.1.2.4.1.2
h3cAdapterType Enumeration .1.3.6.1.4.1.2011.10.10.1.1.2.4.1.3
h3cFcAdapterMode Enumeration .1.3.6.1.4.1.2011.10.10.1.1.2.4.1.4
h3cFcAdapterInitiatorWwpnName H3C-STORAGE-REF-MIBH3cWwpnListType .1.3.6.1.4.1.2011.10.10.1.1.2.4.1.5
h3cFcAdapterTargetWwpnName H3C-STORAGE-REF-MIBH3cWwpnListType .1.3.6.1.4.1.2011.10.10.1.1.2.4.1.6
h3cFcAdapterPortState Enumeration .1.3.6.1.4.1.2011.10.10.1.1.2.4.1.7
h3cFcAdapterModeSwitch r/w H3C-STORAGE-REF-MIBH3cStorageEnableState .1.3.6.1.4.1.2011.10.10.1.1.2.4.1.8
h3cExtVoltageTable .1.3.6.1.4.1.2011.10.10.1.1.2.5
h3cExtVoltageEntry h3cExtVoltagePhysicalIndex .1.3.6.1.4.1.2011.10.10.1.1.2.5.1
h3cExtVoltagePhysicalIndex ENTITY-MIBPhysicalIndex .1.3.6.1.4.1.2011.10.10.1.1.2.5.1.1
h3cExtVoltagePhysicalName SNMP-FRAMEWORK-MIBSnmpAdminString .1.3.6.1.4.1.2011.10.10.1.1.2.5.1.2
h3cExtVoltage Integer32 .1.3.6.1.4.1.2011.10.10.1.1.2.5.1.3
h3cExtVoltageLowThreshold r/w Integer32 .1.3.6.1.4.1.2011.10.10.1.1.2.5.1.4
h3cExtVoltageHighThreshold r/w Integer32 .1.3.6.1.4.1.2011.10.10.1.1.2.5.1.5
h3cExtCriticalVoltageLowThreshold r/w Integer32 .1.3.6.1.4.1.2011.10.10.1.1.2.5.1.6
h3cExtCriticalVoltageHighThreshold r/w Integer32 .1.3.6.1.4.1.2011.10.10.1.1.2.5.1.7
h3cExtShutdownVoltageLowThreshold r/w Integer32 .1.3.6.1.4.1.2011.10.10.1.1.2.5.1.8
h3cExtShutdownVoltageHighThreshold r/w Integer32 .1.3.6.1.4.1.2011.10.10.1.1.2.5.1.9
h3cStorageTraps .1.3.6.1.4.1.2011.10.10.1.1.3
h3cStorageTrapsPrefix .1.3.6.1.4.1.2011.10.10.1.1.3.0
h3cStorageTrapsObjects .1.3.6.1.4.1.2011.10.10.1.1.3.1
h3cSoftwareInfoString H3C-STORAGE-REF-MIBH3cSoftwareInfoString .1.3.6.1.4.1.2011.10.10.1.1.3.1.1
Notifications / Traps (28)
NameOIDDescription
h3cStorCriticalLowerTemperatureThresholdNotification
H3C-ENTITY-EXT-MIBh3cEntityExtPhysicalIndex ENTITY-MIBentPhysicalName H3C-ENTITY-EXT-MIBh3cEntityExtTemperature H3C-ENTITY-EXT-MIBh3cEntityExtCriticalLowerTemperatureThreshold
.1.3.6.1.4.1.2011.10.10.1.1.3.0.1
The h3cStorCriticalLowerTemperatureThresholdNotification indicates
the temperature is lower than the threshold.
          
If the temperature is lower too much than the entity needs,
the entity will halt.
h3cDiskIOErrorNotification
ENTITY-MIBentPhysicalDescr
.1.3.6.1.4.1.2011.10.10.1.1.3.0.10
The h3cDiskIOErrorNotification indicates that a disk occurred I/O error.
h3cRaidCreateNotification
H3C-RAID-MIBh3cRaidUuid H3C-RAID-MIBh3cRaidName
.1.3.6.1.4.1.2011.10.10.1.1.3.0.11
The h3cRaidCreateNotification indicates that a array is created.
h3cRaidDeleteNotification
H3C-RAID-MIBh3cRaidUuid H3C-RAID-MIBh3cRaidName
.1.3.6.1.4.1.2011.10.10.1.1.3.0.12
The h3cRaidDeleteStateNotification indicates that a array is deleted.
h3cRaidHideStateNotification
H3C-RAID-MIBh3cRaidUuid H3C-RAID-MIBh3cRaidName H3C-RAID-MIBh3cRaidHideState
.1.3.6.1.4.1.2011.10.10.1.1.3.0.13
The h3cRaidFailedNotification indicates that a array hide or unhide.
h3cRaidRunStateNotification
H3C-RAID-MIBh3cRaidUuid H3C-RAID-MIBh3cRaidName H3C-RAID-MIBh3cRaidRunState
.1.3.6.1.4.1.2011.10.10.1.1.3.0.14
The h3cRaidDegradeNotification indicates that a array state change.
h3cRaidImportNotification
H3C-RAID-MIBh3cRaidUuid H3C-RAID-MIBh3cRaidName
.1.3.6.1.4.1.2011.10.10.1.1.3.0.15
The h3cRaidFailedNotification indicates that a thrid array is imported.
h3cRaidRebuildStartNotification
H3C-RAID-MIBh3cRaidUuid H3C-RAID-MIBh3cRaidName
.1.3.6.1.4.1.2011.10.10.1.1.3.0.16
The h3cRaidRebuildStartNotification indicates that
a array start to rebuild.
h3cRaidRebuildFinishNotification
H3C-RAID-MIBh3cRaidUuid H3C-RAID-MIBh3cRaidName
.1.3.6.1.4.1.2011.10.10.1.1.3.0.17
The h3cRaidRebuildStartNotification indicates that
a array fininsh rebuild.
h3cRaidRebuildPauseNotification
H3C-RAID-MIBh3cRaidUuid H3C-RAID-MIBh3cRaidName
.1.3.6.1.4.1.2011.10.10.1.1.3.0.18
The h3cRaidRebuildPauseNotification indicates that
pause a array rebuilding.
h3cRaidRebuildInterruptNotification
H3C-RAID-MIBh3cRaidUuid H3C-RAID-MIBh3cRaidName
.1.3.6.1.4.1.2011.10.10.1.1.3.0.19
The h3cRaidRebuildInterruptNotification indicates that
interrupt a array rebuilding.
h3cStorTemperatureTooLow
H3C-ENTITY-EXT-MIBh3cEntityExtPhysicalIndex ENTITY-MIBentPhysicalName H3C-ENTITY-EXT-MIBh3cEntityExtTemperature H3C-ENTITY-EXT-MIBh3cEntityExtShutdownLowerTemperatureThreshold
.1.3.6.1.4.1.2011.10.10.1.1.3.0.2
The h3cStorTemperatureTooLow indicates the temperature is
lower than the threshold.
          
If the temperature is lower too much than the entity needs,
the entity halts now.
h3cSoftwareModuleFailNotification .1.3.6.1.4.1.2011.10.10.1.1.3.0.20
The h3cSoftwareModuleFailNotification indicates that software module(s) fail.
h3cRaidBatteryExpiredNotification .1.3.6.1.4.1.2011.10.10.1.1.3.0.21
The h3cRaidBatteryExpiredNotification indicates
RAID Battery lifetime had expired.
h3cRaidBatteryWillExpireNotification .1.3.6.1.4.1.2011.10.10.1.1.3.0.22
The h3cRaidBatteryWillExpireNotification indicates
RAID Battery lifetime will expire.
h3cLvOnlineFailNotification
H3C-RAID-MIBh3cRaidUuid H3C-RAID-MIBh3cRaidName
.1.3.6.1.4.1.2011.10.10.1.1.3.0.23
The h3cLvOnlineFailNotification indicates lv(s) on vd fail to online.
h3cLvOfflineFailNotification
H3C-RAID-MIBh3cRaidUuid H3C-RAID-MIBh3cRaidName
.1.3.6.1.4.1.2011.10.10.1.1.3.0.24
The h3cLvOfflineFailNotification indicates lv(s) on vd fail to offline.
h3cRaidRunNotification
H3C-RAID-MIBh3cRaidUuid H3C-RAID-MIBh3cRaidName
.1.3.6.1.4.1.2011.10.10.1.1.3.0.25
The h3cRaidRunNotification indicates that a array is running.
h3cExtVoltageNormal .1.3.6.1.4.1.2011.10.10.1.1.3.0.26
The h3cStorVoltageRecoveryNotification indicates
the Voltage has recovered in reference.
h3cDiskPowerOnNotification
ENTITY-MIBentPhysicalDescr
.1.3.6.1.4.1.2011.10.10.1.1.3.0.27
The h3cDiskPowerOnNotification indicates that
a disk is power on.
h3cDiskPowerOffNotification
ENTITY-MIBentPhysicalDescr H3C-DISK-MIBh3cDiskPowerOffReason
.1.3.6.1.4.1.2011.10.10.1.1.3.0.28
The h3cDiskPowerOffNotification indicates that
a disk is power off.
h3cExtVoltageLowThresholdNotification .1.3.6.1.4.1.2011.10.10.1.1.3.0.3
The h3cExtVoltageLowThresholdNotification indicates
the Voltage is lower than the low-threshold.
h3cExtVoltageHighThresholdNotification .1.3.6.1.4.1.2011.10.10.1.1.3.0.4
The h3cExtVoltageHighThresholdNotification indicates
the Voltage is lower than the high-threshold.
h3cExtCriticalVoltageLowThresholdNotification .1.3.6.1.4.1.2011.10.10.1.1.3.0.5
The h3cExtCriticalVoltageLowThresholdNotification indicates
the Voltage is lower than the critical low threshold.
h3cExtCriticalVoltageHighThresholdNotification .1.3.6.1.4.1.2011.10.10.1.1.3.0.6
The h3cExtCriticalVoltageHighThresholdNotification indicates
the Voltage is higher than the critical high threshold.
h3cExtVoltageTooLow .1.3.6.1.4.1.2011.10.10.1.1.3.0.7
The h3cExtVoltageTooLowNotification indicates
the Voltage is lower than the critical low threshold,
and the entity halt now!
h3cExtVoltageTooHigh .1.3.6.1.4.1.2011.10.10.1.1.3.0.8
The h3cExtVoltageTooHighNotification indicates
the Voltage is higher than the critical high threshold,
and the entity halt now!
h3cExtBatteryStateNotification
H3C-ENTITY-EXT-MIBh3cEntityExtPhysicalIndex ENTITY-MIBentPhysicalName H3C-ENTITY-EXT-MIBh3cEntityExtOperStatus
.1.3.6.1.4.1.2011.10.10.1.1.3.0.9
The h3cExtBatteryStateNotification indicates
the raid battery entity's state changes.