GUDEADS-PDU835X-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
4
Rows
4
Columns
33
.1.3.6.1.4.1.28507.52.1.1.1.2 · 1 row entry · 2 columns
list of all Trap receiver
pdu835XTrapIPEntry entry .1.3.6.1.4.1.28507.52.1.1.1.2.1
an entry containing management
informations regarding the list of trap
receivers
Indexes
pdu835XTrapIPIndex
Column Syntax OID
pdu835XTrapIPIndex
A unique value, greater than zero, for each receiver slot.
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.28507.52.1.1.1.2.1.1
pdu835XTrapAddr
DNS name or IP address specifying one Trap receiver slot.
A port can optionally be specified: 'name:port' An empty
string disables this slot.
OctetStringr/w
Constraints:
range: 0-99
.1.3.6.1.4.1.28507.52.1.1.1.2.1.2
.1.3.6.1.4.1.28507.52.1.5.1.2 · 1 row entry · 23 columns
All available Channel Interfaces.
pdu835XPowerEntry entry .1.3.6.1.4.1.28507.52.1.5.1.2.1
An entry containing management information
applicable to a particular Power Channel.
Indexes
pdu835XPowerIndex
Column Syntax OID
pdu835XPowerIndex
Index of Power Channel entries
Integer32
Constraints:
range: 1-6
.1.3.6.1.4.1.28507.52.1.5.1.2.1.1
pdu835XChanStatus
0 = data not active, 1 = data valid
Integer32
Constraints:
range: 0-1
.1.3.6.1.4.1.28507.52.1.5.1.2.1.2
pdu835XAbsEnergyActive
Absolute Active Energy counter.
WhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.52.1.5.1.2.1.3
pdu835XPowerActive
Active Power
WSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.28507.52.1.5.1.2.1.4
pdu835XCurrent
Actual Curent on Power Channel.
mASNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.52.1.5.1.2.1.5
pdu835XVoltage
Actual Voltage on Power Channel
VSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.52.1.5.1.2.1.6
pdu835XFrequency
Frequency of Power Channel
0.01 hzSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.52.1.5.1.2.1.7
pdu835XPowerFactor
Power Factor of Channel between
-1.0 and 1.00
0.001SNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.28507.52.1.5.1.2.1.8
pdu835XPangle
Phase Angle between Voltage
and L Line Current between
-180.0 and 180.0
0.1 degreeSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.28507.52.1.5.1.2.1.9
pdu835XPowerApparent
L Line Mean Apparent Power
VASNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.28507.52.1.5.1.2.1.10
pdu835XPowerReactive
L Line Mean Reactive Power
VARSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.28507.52.1.5.1.2.1.11
pdu835XAbsEnergyReactive
Absolute Reactive Energy counter.
VARhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.52.1.5.1.2.1.12
pdu835XAbsEnergyActiveResettable
Resettable Absolute Active Energy counter.
WhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.52.1.5.1.2.1.13
pdu835XAbsEnergyReactiveResettable
Resettable Absolute Reactive Energy counter.
VARhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.52.1.5.1.2.1.14
pdu835XResetTime
Time in seconds since last Energy
Counter reset.
sSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.52.1.5.1.2.1.15
pdu835XForwEnergyActive
Forward Active Energy counter.
WhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.52.1.5.1.2.1.16
pdu835XForwEnergyReactive
Forward Reactive Energy counter.
VARhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.52.1.5.1.2.1.17
pdu835XForwEnergyActiveResettable
Resettable Forward Active Energy counter.
WhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.52.1.5.1.2.1.18
pdu835XForwEnergyReactiveResettable
Resettable Forward Reactive Energy counter.
VARhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.52.1.5.1.2.1.19
pdu835XRevEnergyActive
Reverse Active Energy counter.
WhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.52.1.5.1.2.1.20
pdu835XRevEnergyReactive
Reverse Reactive Energy counter.
VARhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.52.1.5.1.2.1.21
pdu835XRevEnergyActiveResettable
Resettable Reverse Active Energy counter.
WhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.52.1.5.1.2.1.22
pdu835XRevEnergyReactiveResettable
Resettable Reverse Reactive Energy counter.
VARhSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.52.1.5.1.2.1.23
.1.3.6.1.4.1.28507.52.1.5.3.2 · 1 row entry · 4 columns
pdu835XEntry entry .1.3.6.1.4.1.28507.52.1.5.3.2.1
An entry containing management information
applicable to a particular Power Group.
Entries may not exist on every PDU model.
Indexes
pdu835XPowerGroupIndex
Column Syntax OID
pdu835XPowerGroupIndex Integer32
Constraints:
range: 0-1
.1.3.6.1.4.1.28507.52.1.5.3.2.1.1
pdu835XRCurrent3P
Actual Residual Current. Entry may not exist on models
that support not this type of measurement.
mASNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.52.1.5.3.2.1.2
pdu835XNCurrent3P
Actual Current of the neutral wire. Entry may not exist
on models that support not this type of measurement.
mASNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.28507.52.1.5.3.2.1.3
pdu835XMeasurementBoxConnected
Shows if the external Measurement Box is connected.
Enumeration
Enumerated Values:
0disconnected
1connected
.1.3.6.1.4.1.28507.52.1.5.3.2.1.4
.1.3.6.1.4.1.28507.52.1.6.1 · 1 row entry · 4 columns
pdu835XSensorEntry entry .1.3.6.1.4.1.28507.52.1.6.1.1
Indexes
pdu835XSensorIndex
Column Syntax OID
pdu835XSensorIndex Integer32
Constraints:
range: 1-2
.1.3.6.1.4.1.28507.52.1.6.1.1.1
pdu835XTempSensor
actual temperature, a value of -9999 indicates
that data is not available
0.1 degree CelsiusSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.28507.52.1.6.1.1.2
pdu835XHygroSensor
actual humidity, a value of -9999 indicates
that data is not available
0.1 percent humiditySNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.28507.52.1.6.1.1.3
pdu835XInputSensor
logical state of input sensor
Enumeration
Enumerated Values:
0off
1on