DELLEMC-OS10-CHASSIS-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
5
Rows
5
Columns
46
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.3 · 1 row entry · 14 columns
A list of chassis in a cluster.
The chassis table contains the information of  
 each chassis in the cluster.
os10ChassisEntry entry .1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1
A list of chassis entries containing information
for the chassis.
Indexes
No indexes recorded
Column Syntax OID
os10ChassisIndex
A unique index for each chassis within
the cluster.
This value is the chassisId assigned to the chassis.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.1
os10ChassisType
The Dell EMC Networking Model number of the chassis.
DELLEMC-OS10-TC-MIBOs10ChassisDefType
Textual Convention: DELLEMC-OS10-TC-MIBOs10ChassisDefType Enumeration
Type Values:
1s6000on
2s4048on
3s4048Ton
4s3048on
5s6010on
6s4148Fon
7s4128Fon
8s4148Ton
9s4128Ton
10s4148FEon
11s4148Uon
12s4200on
13mx5108Non
14mx9116Non
15s5148Fon
16z9100on
17s4248FBon
18s4248FBLon
19s4112Fon
20s4112Ton
21z9264Fon
22z9224Fon
23s5212Fon
24s5224Fon
25s5232Fon
26s5248Fon
27s5296Fon
28z9332Fon
29n3248TEon
9999unknown
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.2
os10ChassisMacAddr
A 6-octet MAC Address assigned to this chassis.
SNMPv2-TCMacAddress
Textual Convention: SNMPv2-TCMacAddress OctetString
Type Constraints:
range: 6
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.3
os10ChassisPartNum
The chassis manufacturer's part number.
OctetString
Enumerated Values:
1unknown
2ac
3dc
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.4
os10ChassisPPID
The chassis manufacturer's PPID.
OctetString
Constraints:
range: 0-24
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.5
os10ChassisHwRev
The chassis hardware revision number.
OctetString
Constraints:
range: 0-7
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.6
os10ChassisServiceTag
The chassis's service tag.
OctetString
Constraints:
range: 0-14
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.7
os10ChassisExpServiceCode
The chassis's express service code.
OctetString .1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.8
os10ChassisNumFanTrays
Number of fan trays in the chassis.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.9
os10ChassisNumPowerSupplies
Number of power supplies in the chassis.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.10
os10ChassisTemp
Temperature of the chassis.
degrees CentigradeSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.11
os10ChassisProductBase
The solution id product base
OctetString .1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.12
os10ChassisProductSN
The solution id product serial number
OctetString .1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.13
os10ChassisProductPN
The solution id product part number
OctetString
Constraints:
range: 0-24
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.14
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.4 · 1 row entry · 10 columns
A list of line cards resident in the chassis.
This table contains the information on each RPM and linecards
in the chassis.
os10CardEntry entry .1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1
Entry for each card in the chassis.
Indexes
No indexes recorded
Column Syntax OID
os10CardIndex
A unique index for each card in the chassis.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.1
os10CardType
Card's type.
DELLEMC-OS10-TC-MIBOs10SystemCardType
Textual Convention: DELLEMC-OS10-TC-MIBOs10SystemCardType Enumeration
Type Values:
0notPresent
1s6000on
2s4048on
3s4048Ton
4s3048on
5s6010on
6s4148Fon
7s4128Fon
8s4148Ton
9s4128Ton
10s4148FEon
11s4148Uon
12s4200on
13mx5108Non
14mx9116Non
15s5148Fon
16z9100on
17s4248FBon
18s4248FBLon
19s4112Fon
20s4112Ton
21z9264Fon
22z9232Fon
23s5212Fon
24s5224Fon
25s5232Fon
26s5248Fon
27s5296Fon
28z9332Fon
29n3248TEon
9999unknown
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.2
os10CardDescription
A short description of the card.
OctetString .1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.3
os10CardStatus
The current operational state of the card.
DELLEMC-OS10-TC-MIBOs10CardOperStatus
Textual Convention: DELLEMC-OS10-TC-MIBOs10CardOperStatus Enumeration
Type Values:
1ready
2cardMisMatch
3cardProblem
4diagMode
5cardAbsent
6offline
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.4
os10CardTemp
Temperature of the card.
degrees CentigradeSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.5
os10CardPartNum
The card's part number
OctetString
Enumerated Values:
1psu
2fanTray
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.6
os10CardPPID
The card's PPID.
OctetString .1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.7
os10CardHwRev
The card's manufacturer hardware revision number.
OctetString .1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.8
os10CardServiceTag
The card's service tag.
OctetString .1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.9
os10CardExpServiceCode
The card's express service code.
OctetString .1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.10
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.1 · 1 row entry · 8 columns
A list of power supplies resident 
in the device.
os10PowerSupplyEntry entry .1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1
A power supply entry provides all attributes of
that power supply.
Indexes
No indexes recorded
Column Syntax OID
os10PowerSupplyIndex
The unique index of the power supply.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.1
os10PowerSupplyDevice
Identify the type of device the power supply unit resides
(chassis,line card etc..)
DELLEMC-OS10-TC-MIBOs10DeviceType
Textual Convention: DELLEMC-OS10-TC-MIBOs10DeviceType Enumeration
Type Values:
1chassis
2stack
3rpm
4supervisor
5linecard
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.2
os10PowerSupplyDeviceIndex
A unique value indentifying a specific os10PowerSupplyDeviceType.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.3
os10PowerSupplyOperStatus
The status of the power supply.
DELLEMC-OS10-TC-MIBOs10CmnOperStatus
Textual Convention: DELLEMC-OS10-TC-MIBOs10CmnOperStatus Enumeration
Type Values:
1up
2down
3testing
4unknown
5dormant
6notPresent
7lowerLayerDown
8failed
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.4
os10PowerSupplyType
The type of the power supply.
Enumeration .1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.5
os10PowerSupplyPPID
The power supply's PPID.
OctetString .1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.6
os10PowerSupplyServiceTag
The power supply's service tag.
OctetString .1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.7
os10PowerSupplyExpServiceCode
The power supply's express service code.
OctetString .1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.8
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.2 · 1 row entry · 7 columns
A list of fan trays resident in the device.
os10FanTrayEntry entry .1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1
A fan entry containing objects for a
particular fan tray.
Indexes
No indexes recorded
Column Syntax OID
os10FanTrayIndex
The unique index of the fan tray.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.1
os10FanTrayDevice
Identify the type of device this fan tray unit resides
(chassis,line card etc..)
DELLEMC-OS10-TC-MIBOs10DeviceType
Textual Convention: DELLEMC-OS10-TC-MIBOs10DeviceType Enumeration
Type Values:
1chassis
2stack
3rpm
4supervisor
5linecard
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.2
os10FanTrayDeviceIndex
A unique value indentifying a specific os10FanTrayDevice.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.3
os10FanTrayOperStatus
The status of the fan tray.
DELLEMC-OS10-TC-MIBOs10CmnOperStatus
Textual Convention: DELLEMC-OS10-TC-MIBOs10CmnOperStatus Enumeration
Type Values:
1up
2down
3testing
4unknown
5dormant
6notPresent
7lowerLayerDown
8failed
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.4
os10FanTrayPPID
The fan tray's PPID.
OctetString .1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.5
os10FanTrayServiceTag
The fan tray's service tag.
OctetString .1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.6
os10FanTrayExpServiceCode
The fan tray's express service code.
OctetString .1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.7
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.3 · 1 row entry · 7 columns
A list of fans installed in the chassis.
os10FanEntry entry .1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1
A fan entry containing objects for a
particular fan in the chassis.
Indexes
No indexes recorded
Column Syntax OID
os10FanIndex
The unique value for each fan in the device.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.1
os10FanDevice
Identify the type of device this fan resides.
(chassis,line card etc..)
DELLEMC-OS10-TC-MIBOs10DeviceType
Textual Convention: DELLEMC-OS10-TC-MIBOs10DeviceType Enumeration
Type Values:
1chassis
2stack
3rpm
4supervisor
5linecard
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.2
os10FanDeviceIndex
A unique value indentifying a specific os10FanDevice.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.3
os10FanEntity
Identify the type of system componet where the fan is installed.
Enumeration .1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.4
os10FanEntitySlot
A unique value indentifying a specific os10FanEntity.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.5
os10FanId
A unique value indentifying a specific fan in a specific os10FanEntity.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.6
os10FanOperStatus
The status of the fan.
DELLEMC-OS10-TC-MIBOs10CmnOperStatus
Textual Convention: DELLEMC-OS10-TC-MIBOs10CmnOperStatus Enumeration
Type Values:
1up
2down
3testing
4unknown
5dormant
6notPresent
7lowerLayerDown
8failed