os10ChassisType
DELLEMC-OS10-CHASSIS-MIB ·
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.2
Object
column
DELLEMC-OS10-TC-MIBOs10ChassisDefType
The Dell EMC Networking Model number of the chassis.
Context
- MIB
- DELLEMC-OS10-CHASSIS-MIB
- OID
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.2- Type
- column
- Access
- readonly
- Status
- current
- Parent
- os10ChassisEntry
- Table
- os10ChassisTable
- Siblings
- 13
Syntax
DELLEMC-OS10-TC-MIBOs10ChassisDefType
- Source
- DELLEMC-OS10-TC-MIBOs10ChassisDefType
- Base type
Enumeration
Values & Constraints
Type Values
1 | s6000on |
2 | s4048on |
3 | s4048Ton |
4 | s3048on |
5 | s6010on |
6 | s4148Fon |
7 | s4128Fon |
8 | s4148Ton |
9 | s4128Ton |
10 | s4148FEon |
11 | s4148Uon |
12 | s4200on |
13 | mx5108Non |
14 | mx9116Non |
15 | s5148Fon |
16 | z9100on |
17 | s4248FBon |
18 | s4248FBLon |
19 | s4112Fon |
20 | s4112Ton |
21 | z9264Fon |
22 | z9224Fon |
23 | s5212Fon |
24 | s5224Fon |
25 | s5232Fon |
26 | s5248Fon |
27 | s5296Fon |
28 | z9332Fon |
29 | n3248TEon |
9999 | unknown |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| os10ChassisIndex A unique index for each chassis within
the cluster.
This value is the chassisId assigned to the chassis. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.1 |
| os10ChassisNumPowerSupplies Number of power supplies in the chassis. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.10 |
| os10ChassisTemp Temperature of the chassis. | column | degrees Centigrade SNMPv2-SMIInteger32 | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.11 |
| os10ChassisProductBase The solution id product base | column | OctetString | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.12 |
| os10ChassisProductSN The solution id product serial number | column | OctetString | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.13 |
| os10ChassisProductPN The solution id product part number | column | OctetString | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.14 |
| os10ChassisMacAddr A 6-octet MAC Address assigned to this chassis. | column | SNMPv2-TCMacAddress | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.3 |
| os10ChassisPartNum The chassis manufacturer's part number. | column | OctetString | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.4 |
| os10ChassisPPID The chassis manufacturer's PPID. | column | OctetString | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.5 |
| os10ChassisHwRev The chassis hardware revision number. | column | OctetString | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.6 |
| os10ChassisServiceTag The chassis's service tag. | column | OctetString | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.7 |
| os10ChassisExpServiceCode The chassis's express service code. | column | OctetString | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.8 |
| os10ChassisNumFanTrays Number of fan trays in the chassis. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.9 |