CTRON-POWER-SUPPLY-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
5
Rows
5
Columns
39

chPowerTable

table mandatory
.1.3.6.1.4.1.52.4.1.1.7.1.8 · 1 row entry · 6 columns
A list of power lines or busses on the chassis's backplane.
chPowerEntry entry .1.3.6.1.4.1.52.4.1.1.7.1.8.1
A slot entry containing objects for a particular
module and associated power line.
Indexes
chPowerLineID
Column Syntax OID
chPowerLineID mandatory
A unique value used to identify a particular power line on
the chassis's backplane.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.1.8.1.1
chPowerLineType mandatory
The type of power. For example, a power line that supplies
DC current at a nominal voltage of 40 to 57 volts or a
power line that supplies AC current at a nominal volatge of
110v.
ObjectIdentifier .1.3.6.1.4.1.52.4.1.1.7.1.8.1.2
chPowerLineTotalSupply mandatory
The total power being supplied by the chassis's power
supplies to the chassis on this power line. The value
of this object is the actual watts.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.1.8.1.3
chPowerLineTotalLoad mandatory
The total load being presented by the chassis to the
chassis's power supplies on this power line. This value
will be zero if unknown The value of this object is the
actual watts.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.1.8.1.4
chPowerLineMaxSupply mandatory
The maximum power that could de supplied by the chassis's power
supplies to the chassison this power line. The value of
this object is the actual watts.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.1.8.1.5
chPowerLineMaxLoad mandatory
The maximum load that could be presented by the chassis to the
chassis's power supplies on this power line. The value of
this object is the actual watts.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.1.8.1.6
.1.3.6.1.4.1.52.4.1.1.7.2.1 · 1 row entry · 9 columns
A list of networking modules installed in this chassis.
boardPowerSlotStatusEntry entry .1.3.6.1.4.1.52.4.1.1.7.2.1.1
A slot entry containing objects for a particular
module.
Indexes
boardPowerSlotStatusID
Column Syntax OID
boardPowerSlotStatusID mandatory
The slot number of a chassis slot in which this board is
installed. This object is similiar to chSlotID in the
Chassis MIB.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.2.1.1.1
boardPowerOperationalStatus mandatory
This object reflects the status of the module's
DC-DC converter power supply.
Enumeration
Enumerated Values:
1powerOn
2powerOff
3reset
4overVoltage
5underVoltage
6overCurrent
7overCurrentShutdown
8temperatureShutdown
9remotePowerOff
10powerConservationShutdown
11frontPanelPowerOff
.1.3.6.1.4.1.52.4.1.1.7.2.1.1.2
boardPowerAdminStatus mandatory
This object controls the operation of the module's
DC-DC power supply. If the value 3 is written to
this object then the value of the object will be
set to 1 after the reset is performed.
Enumerationr/w
Enumerated Values:
1powerOn
2powerOff
3reset
.1.3.6.1.4.1.52.4.1.1.7.2.1.1.3
boardPowerLocalAdminStatus mandatory
This object controls the operation of the module's
front panel button. In local mode this button may
be used to locally control the operation of the
DC-DC converter, i.e. power on, power off and
reset. In secure mode …
Enumerationr/w
Enumerated Values:
1localMode
2secureMode
.1.3.6.1.4.1.52.4.1.1.7.2.1.1.4
boardPowerLocalStatus mandatory
This object reflects the state of the module's front
panel button.
Enumeration
Enumerated Values:
1resetRequest
2powerDownRequest
3powerOnRequest
4normal
.1.3.6.1.4.1.52.4.1.1.7.2.1.1.5
boardPowerShutdownAdmin mandatory
This object controls whether or not the module should
auto power down due to an fault condition.
Enumerationr/w
Enumerated Values:
1enabled
2disabled
.1.3.6.1.4.1.52.4.1.1.7.2.1.1.6
boardPowerPriority mandatory
The module's power-up and power down priority. This is a
value of 1 to 14 and is used to decide which modules are
allowed to power on in the event that power demand of the
chassis is greater than the total power supply.…
Integer32r/w
Constraints:
range: 1-14
.1.3.6.1.4.1.52.4.1.1.7.2.1.1.7
boardPowerMaxInputPower mandatory
The maximum input power that this module is allowed
to consume. The value of this object is actual
watts.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.2.1.1.8
boardPowerManagement mandatory
Module power management status.
Enumerationr/w
Enumerated Values:
1disabled
2enabled
7not-supported
.1.3.6.1.4.1.52.4.1.1.7.2.1.1.9

boardPowerSlotTable

table mandatory
.1.3.6.1.4.1.52.4.1.1.7.2.2 · 1 row entry · 9 columns
A list of networking modules and associated power lines 
installed in this chassis.
boardPowerSlotEntry entry .1.3.6.1.4.1.52.4.1.1.7.2.2.1
A slot entry containing objects for a particular
module and associated power line.
Indexes
boardPowerSlotID boardPowerID
Column Syntax OID
boardPowerSlotID mandatory
The slot number of a chassis slot in which this board is
installed. This object is similiar to chSlotID in the
Chassis MIB.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.2.2.1.1
boardPowerID mandatory
A unique value used to identify a particular power line.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.2.2.1.2
boardPowerType mandatory
The type of power. For example, a power line that supplies
DC current at a nominal voltage of 40 to 57 volts or a
power line that supplies AC current at a nominal volatge of
110v.
ObjectIdentifier .1.3.6.1.4.1.52.4.1.1.7.2.2.1.3
boardPowerStatus mandatory
This object reflects the status of this power line.
Enumeration
Enumerated Values:
1powerOK
2powerOff
3overCurrent
4overVoltage
5underVoltage
.1.3.6.1.4.1.52.4.1.1.7.2.2.1.4
boardPowerVoltage mandatory
The voltage reading for the power line. The value of this
object is actual voltage * 100.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.2.2.1.5
boardPowerCurrent mandatory
The current reading for the power line. The value of this
object is the actual amperage * 100. If this reading is not
implemented then value will be zero.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.2.2.1.6
boardPowerMaxVoltage mandatory
The maximum voltage for this power line. If the voltage
reading for this power line is greater than this value
then the power line is considered to be in an overvolatge
condition. The value of this object is in voltage…
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.2.2.1.7
boardPowerMinVoltage mandatory
The minimum voltage for this power line. If the voltage
reading for this power line is less than this value
then the power line is considered to be in an undervolatge
condition. The value of this object is voltage * 10…
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.2.2.1.8
boardPowerMaxPower mandatory
The maximum power for this power line. If the power calculated
for this power line is greater than this value then the
power line is considered to be in an overload condition.
The value of this object is in watts.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.2.2.1.9

psPowerSlotStatusTable

table mandatory
.1.3.6.1.4.1.52.4.1.1.7.3.1 · 1 row entry · 4 columns
A list of AC & DC power supplies installed in this chassis.
psPowerSlotStatusEntry entry .1.3.6.1.4.1.52.4.1.1.7.3.1.1
A slot entry containing objects for a particular
power supply.
Indexes
psPowerSlotStatusID
Column Syntax OID
psPowerSlotStatusID mandatory
The slot number of a chassis slot in which this AC power
supply is installed. This object is similiar
to chSlotID in the Chassis MIB.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.3.1.1.1
psPowerOperationalStatus mandatory
This object reflects the status of the module's
DC-DC converter power supply.
Enumeration
Enumerated Values:
1powerOn
2powerOff
3reset
4overVoltage
5underVoltage
6overCurrent
7overCurrentShutdown
8temperatureShutdown
9remotePowerOff
.1.3.6.1.4.1.52.4.1.1.7.3.1.1.2
psPowerAdminStatus mandatory
This object controls the operation of power supply.
Enumerationr/w
Enumerated Values:
1powerOn
2powerOff
.1.3.6.1.4.1.52.4.1.1.7.3.1.1.3
psPowerMaxOutputPower mandatory
The maximum power that this power supply is allowed
to ouput. The value of this object is watts.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.3.1.1.4

psPowerSlotTable

table mandatory
.1.3.6.1.4.1.52.4.1.1.7.3.2 · 1 row entry · 11 columns
A list of power supplies and associated power lines
installed in this chassis.
psPowerSlotEntry entry .1.3.6.1.4.1.52.4.1.1.7.3.2.1
A slot entry containing objects for a particular
power line on a particular power supply.
Indexes
psPowerSlotID psPowerID
Column Syntax OID
psPowerSlotID mandatory
The slot number of a chassis slot in which this Power
supply is installed. This object is similiar to
chSlotID in the Chassis MIB.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.3.2.1.1
psPowerID mandatory
A unique value used to identify a particular power line.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.3.2.1.2
psPowerType mandatory
The type of power. For example, a power line that supplies
DC current at a nominal voltage of 40 to 57 volts or a
power line that supplies AC current at a nominal volatge of
110v.
ObjectIdentifier .1.3.6.1.4.1.52.4.1.1.7.3.2.1.3
psPowerStatus mandatory
This object reflects the status of the power line.
Enumeration
Enumerated Values:
1powerOK
2powerOff
3overCurrent
4overVoltage
5underVoltage
.1.3.6.1.4.1.52.4.1.1.7.3.2.1.4
psPowerAdmin mandatory
This object controls the operation of power supply.
Enumerationr/w
Enumerated Values:
1powerOn
2powerOff
.1.3.6.1.4.1.52.4.1.1.7.3.2.1.5
psPowerVoltage mandatory
The voltage reading for the power line. The value of this
object is the actual voltage * 100.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.3.2.1.6
psPowerCurrent mandatory
The current reading for the power line. The value of this
object is amperage * 100. If this reading is not implemented
then value will be zero.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.3.2.1.7
psPowerLineFrequency mandatory
The line frequency for the power line. The value of this
object is the actual frequency in Hertz * 10. If this
reading is not implemented then value will be zero.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.3.2.1.8
psPowerMaxVoltage mandatory
The maximum voltage for this power line. If the voltage
reading for this power line is greater than this value
then the power line is considered to be in an over volatge
condition. The value of this object is voltage *…
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.3.2.1.9
psPowerMinVoltage mandatory
The minimum voltage for this power line. If the voltage
reading for this power line is greater than this value
then the power line is considered to be in an over volatge
condition. The value of this object is voltage *…
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.3.2.1.10
psPowerMaxPower mandatory
The maximum power for this power line. If the power calculated
for this power line is greater than this value then the
power line is considered to be in an overload condition.
The value of this object is watts.
Integer32
Textual Convention: COPS-PR-SPPIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.3.2.1.11