boardPowerSlotEntry
CTRON-POWER-SUPPLY-MIB ·
.1.3.6.1.4.1.52.4.1.1.7.2.2.1
Object
row
mandatory
A slot entry containing objects for a particular module and associated power line.
Context
- MIB
- CTRON-POWER-SUPPLY-MIB
- OID
.1.3.6.1.4.1.52.4.1.1.7.2.2.1- Type
- row
- Status
- mandatory
- Parent
- boardPowerSlotTable
- Table
- boardPowerSlotTable
- Children
- 9
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| boardPowerSlotID mandatory The slot number of a chassis slot in which this board is
installed. This object is similiar to chSlotID in the
Chassis MIB. | column | Integer32 | .1.3.6.1.4.1.52.4.1.1.7.2.2.1.1 |
| boardPowerID mandatory A unique value used to identify a particular power line. | column | Integer32 | .1.3.6.1.4.1.52.4.1.1.7.2.2.1.2 |
| boardPowerType mandatory The type of power. For example, a power line that supplies
DC current at a nominal voltage of 40 to 57 volts or a
power line that supplies AC current at a nominal volatge of
110v. | column | ObjectIdentifier | .1.3.6.1.4.1.52.4.1.1.7.2.2.1.3 |
| boardPowerStatus mandatory This object reflects the status of this power line. | column | Enumeration | .1.3.6.1.4.1.52.4.1.1.7.2.2.1.4 |
| boardPowerVoltage mandatory The voltage reading for the power line. The value of this
object is actual voltage * 100. | column | Integer32 | .1.3.6.1.4.1.52.4.1.1.7.2.2.1.5 |
| boardPowerCurrent mandatory The current reading for the power line. The value of this
object is the actual amperage * 100. If this reading is not
implemented then value will be zero. | column | Integer32 | .1.3.6.1.4.1.52.4.1.1.7.2.2.1.6 |
| boardPowerMaxVoltage mandatory The maximum voltage for this power line. If the voltage
reading for this power line is greater than this value
then the power line is considered to be in an overvolatge
condition… | column | Integer32 | .1.3.6.1.4.1.52.4.1.1.7.2.2.1.7 |
| boardPowerMinVoltage mandatory The minimum voltage for this power line. If the voltage
reading for this power line is less than this value
then the power line is considered to be in an undervolatge
condition. … | column | Integer32 | .1.3.6.1.4.1.52.4.1.1.7.2.2.1.8 |
| boardPowerMaxPower mandatory The maximum power for this power line. If the power calculated
for this power line is greater than this value then the
power line is considered to be in an overload condition.
T… | column | Integer32 | .1.3.6.1.4.1.52.4.1.1.7.2.2.1.9 |
Indexes
| Object | Type | Syntax | OID |
|---|---|---|---|
| boardPowerSlotID mandatory The slot number of a chassis slot in which this board is
installed. This object is similiar to chSlotID in the
Chassis MIB. | column | Integer32 | .1.3.6.1.4.1.52.4.1.1.7.2.2.1.1 |
| boardPowerID mandatory A unique value used to identify a particular power line. | column | Integer32 | .1.3.6.1.4.1.52.4.1.1.7.2.2.1.2 |