BRCM-BATTERY-MGMT-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
2
Rows
2
Columns
30
batteryTable
table.1.3.6.1.4.1.4413.2.2.2.1.10.1.1
·
1 row entry
·
26 columns
A table of batteries present on the system.
An entry describing the characteristics of an individual battery.
Indexes
battIndex
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
battIndex
Identifies the instance number of this individual battery.
|
Integer32 Constraints: range: 1-4 |
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.1 |
||||
|
battCapacity
The charge capacity of this battery.
|
milliamp hoursSNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.2 |
||||
|
battMaximumVoltage
The voltage at which this battery is considered to be fully charged.
Note that if battChargerMaximumCharge is set to less than 100%, the battery will never be charged to this voltage. |
millivoltsSNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.3 |
||||
|
battMinimumVoltage
The voltage at which this battery is considered to be fully
discharged. |
millivoltsSNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.4 |
||||
|
battMeasuredVoltage
The most recently measured voltage of this battery.
|
millivoltsSNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.5 |
||||
|
battIsValid
Indicates whether this battery is considered valid by the battery
charger. A value of false(2) here indicates some kind of failure with this battery. |
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.6 |
||||
|
battIsSelected
Indicates whether this battery is currently selected for charging or
discharging. |
SNMPv2-TCTruthValue Textual Convention: SNMPv2-TCTruthValue EnumerationType Values:
|
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.7 |
||||
|
battEstimatedMinutesRemaining
An estimate of the time to depletion of this battery's charge
under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off. |
minutesUPS-MIBPositiveInteger Textual Convention: UPS-MIBPositiveInteger Integer32Type Constraints: range: 1..2147483647 |
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.8 |
||||
|
battEstimatedChargeRemaining
An estimate of this battery's charge remaining expressed
as a percent of full charge. |
percentInteger32 Constraints: range: 0-100 |
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.9 |
||||
|
battErrors
Indicates the number of errors reported by the charger when trying
to charge this battery. This object should always have a value of zero if all is well with the charger and the battery. |
SNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.10 |
||||
|
battEpromRevision
The version of the battery EPROM.
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.11 |
||||
|
battPackSupplier
Battery Pack Supplier
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.12 |
||||
|
battModelNumber
Battery Model Number.
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.13 |
||||
|
battSerialNumber
Battery Serial Number.
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.14 |
||||
|
battCellSupplier
Battery Cell Supplier.
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.15 |
||||
|
battCellCapacity
Battery Cell Capacity.
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.16 |
||||
|
battCellDateCode
Battery Cell Date Code(mmddyy).
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.17 |
||||
|
battPackDateCode
Battery Pack Date Code(mmddyy).
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.18 |
||||
|
battTemperature
The temperature as reported by this battery. If the battery pack does
not support temperature measurement then this object will not be supported. |
degrees CentigradeSNMPv2-SMIInteger32 Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.19 |
||||
|
battPackGUID
The battery pack globally unique ID (0x<cc><iiiiiiii><ff>).
Where <cc> is an 8-bit CRC, <iiiiiiii> is the 48-bit ID, and <ff> is the 8-bit family code. If the hardware does not support reading the GUID then this object… |
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.20 |
||||
|
battActualCapacity
The current maximum charge capacity of this battery. If the hardware
does not support periodic life testing, this will return the same value as battDesignCapacity |
milliamp hoursSNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.21 |
||||
|
battAge
Specifies the current age of the battery as a percentage of its design
capacity. This value could be calculated by dividing battActualCapacity by battDesignCapacity (however, this value clips at 100%.) |
percentUnsigned32 Constraints: range: 0-100 |
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.22 |
||||
|
battNextLifeTest
Returns/specifies the date and time of the next life test (mmddyyyy hh:mm:ss)
for the specified pack. If the charger does not support periodic life testing then this object will not be supported. Setting this object t… |
SNMPv2-TCDisplayStringr/w Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.23 |
||||
|
battDischargeTable
Returns the full discharge table for the specified battery as a comma-delimited string
|
OctetString | .1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.24 |
||||
|
battCompressedDischargeTable
Returns the compressed discharge table from the specified battery
|
OctetString | .1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.25 |
||||
|
battInvalidateNonVolSlot
Invalidates the specified non-vol slot
|
Unsigned32r/w Constraints: range: 0-1 |
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.26 |
.1.3.6.1.4.1.4413.2.2.2.1.10.5.1
·
1 row entry
·
4 columns
A table of thermal sensors present on the system.
An entry describing a single thermal sensor.
Indexes
battThermalSensorType battThermalSensorIndex
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
battThermalSensorType
Identifies the type of this thermal sensor.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.4413.2.2.2.1.10.5.1.1.1 |
||||||
|
battThermalSensorIndex
Identifies the instance number of this thermal sensor.
|
Integer32 Constraints: range: 0-8 |
.1.3.6.1.4.1.4413.2.2.2.1.10.5.1.1.2 |
||||||
|
battThermalSensorDescription
A textual description of this thermal sensor.
|
SNMPv2-TCDisplayString Textual Convention: SNMPv2-TCDisplayString OctetStringType Constraints: range: 0..255 |
.1.3.6.1.4.1.4413.2.2.2.1.10.5.1.1.3 |
||||||
|
battThermalSensorTemperature
The temperature as reported by this thermal sensor.
|
degrees CentigradeSNMPv2-SMIInteger32 Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4413.2.2.2.1.10.5.1.1.4 |