BRCM-BATTERY-MGMT-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
2
Rows
2
Columns
30
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1 · 1 row entry · 26 columns
A table of batteries present on the system.
batteryEntry entry .1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1
An entry describing the characteristics of an individual battery.
Indexes
battIndex
Column Syntax OID
battIndex
Identifies the instance number of this individual battery.
Integer32
Constraints:
range: 1-4
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.1
battCapacity
The charge capacity of this battery.
milliamp hoursSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.2
battMaximumVoltage
The voltage at which this battery is considered to be fully charged.
Note that if battChargerMaximumCharge is set to less than 100%, the
battery will never be charged to this voltage.
millivoltsSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.3
battMinimumVoltage
The voltage at which this battery is considered to be fully
discharged.
millivoltsSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.4
battMeasuredVoltage
The most recently measured voltage of this battery.
millivoltsSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.5
battIsValid
Indicates whether this battery is considered valid by the battery
charger. A value of false(2) here indicates some kind of failure
with this battery.
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.6
battIsSelected
Indicates whether this battery is currently selected for charging or
discharging.
SNMPv2-TCTruthValue
Textual Convention: SNMPv2-TCTruthValue Enumeration
Type Values:
1true
2false
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.7
battEstimatedMinutesRemaining
An estimate of the time to depletion of this battery's charge
under the present load conditions if the utility power
is off and remains off, or if it were to be lost and
remain off.
minutesUPS-MIBPositiveInteger
Textual Convention: UPS-MIBPositiveInteger Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.8
battEstimatedChargeRemaining
An estimate of this battery's charge remaining expressed
as a percent of full charge.
percentInteger32
Constraints:
range: 0-100
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.9
battErrors
Indicates the number of errors reported by the charger when trying
to charge this battery. This object should always have a value of
zero if all is well with the charger and the battery.
SNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.10
battEpromRevision
The version of the battery EPROM.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.11
battPackSupplier
Battery Pack Supplier
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.12
battModelNumber
Battery Model Number.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.13
battSerialNumber
Battery Serial Number.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.14
battCellSupplier
Battery Cell Supplier.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.15
battCellCapacity
Battery Cell Capacity.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.16
battCellDateCode
Battery Cell Date Code(mmddyy).
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.17
battPackDateCode
Battery Pack Date Code(mmddyy).
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.18
battTemperature
The temperature as reported by this battery. If the battery pack does
not support temperature measurement then this object will not be
supported.
degrees CentigradeSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.19
battPackGUID
The battery pack globally unique ID (0x<cc><iiiiiiii><ff>).
Where <cc> is an 8-bit CRC, <iiiiiiii> is the 48-bit ID, and <ff> is
the 8-bit family code. If the hardware does not support reading
the GUID then this object…
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.20
battActualCapacity
The current maximum charge capacity of this battery. If the hardware
does not support periodic life testing, this will return the same
value as battDesignCapacity
milliamp hoursSNMPv2-SMIUnsigned32
Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.21
battAge
Specifies the current age of the battery as a percentage of its design
capacity. This value could be calculated by dividing battActualCapacity
by battDesignCapacity (however, this value clips at 100%.)
percentUnsigned32
Constraints:
range: 0-100
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.22
battNextLifeTest
Returns/specifies the date and time of the next life test (mmddyyyy hh:mm:ss)
for the specified pack. If the charger does not support periodic life
testing then this object will not be supported. Setting this object t…
SNMPv2-TCDisplayStringr/w
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.23
battDischargeTable
Returns the full discharge table for the specified battery as a comma-delimited string
OctetString .1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.24
battCompressedDischargeTable
Returns the compressed discharge table from the specified battery
OctetString .1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.25
battInvalidateNonVolSlot
Invalidates the specified non-vol slot
Unsigned32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.26
.1.3.6.1.4.1.4413.2.2.2.1.10.5.1 · 1 row entry · 4 columns
A table of thermal sensors present on the system.
batteryThermalSensorEntry entry .1.3.6.1.4.1.4413.2.2.2.1.10.5.1.1
An entry describing a single thermal sensor.
Indexes
battThermalSensorType battThermalSensorIndex
Column Syntax OID
battThermalSensorType
Identifies the type of this thermal sensor.
Enumeration
Enumerated Values:
1batteryPackSensor
2boardLevelTemperatureSensor
3thermalShutdownControllerSensor
.1.3.6.1.4.1.4413.2.2.2.1.10.5.1.1.1
battThermalSensorIndex
Identifies the instance number of this thermal sensor.
Integer32
Constraints:
range: 0-8
.1.3.6.1.4.1.4413.2.2.2.1.10.5.1.1.2
battThermalSensorDescription
A textual description of this thermal sensor.
SNMPv2-TCDisplayString
Textual Convention: SNMPv2-TCDisplayString OctetString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.4413.2.2.2.1.10.5.1.1.3
battThermalSensorTemperature
The temperature as reported by this thermal sensor.
degrees CentigradeSNMPv2-SMIInteger32
Textual Convention: SNMPv2-SMIInteger32 Integer32
Type Constraints:
range: -2147483648..2147483647