battModelNumber
BRCM-BATTERY-MGMT-MIB ·
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.13
Object
column
SNMPv2-TCDisplayString
Battery Model Number.
Context
- MIB
- BRCM-BATTERY-MGMT-MIB
- OID
.1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.13- Type
- column
- Access
- readonly
- Status
- current
- Parent
- batteryEntry
- Table
- batteryTable
- Siblings
- 25
Values & Constraints
Type Constraints
range: 0..255
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| battIndex Identifies the instance number of this individual battery. | column | Integer32 | .1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.1 |
| battErrors Indicates the number of errors reported by the charger when trying
to charge this battery. This object should always have a value of
zero if all is well with the charger and the … | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.10 |
| battEpromRevision The version of the battery EPROM. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.11 |
| battPackSupplier Battery Pack Supplier | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.12 |
| battSerialNumber Battery Serial Number. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.14 |
| battCellSupplier Battery Cell Supplier. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.15 |
| battCellCapacity Battery Cell Capacity. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.16 |
| battCellDateCode Battery Cell Date Code(mmddyy). | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.17 |
| battPackDateCode Battery Pack Date Code(mmddyy). | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.18 |
| battTemperature The temperature as reported by this battery. If the battery pack does
not support temperature measurement then this object will not be
supported. | column | degrees Centigrade SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.19 |
| battCapacity The charge capacity of this battery. | column | milliamp hours SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.2 |
| battPackGUID The battery pack globally unique ID (0x<cc><iiiiiiii><ff>).
Where <cc> is an 8-bit CRC, <iiiiiiii> is the 48-bit ID, and <ff> is
the 8-bit family code. If the hardware does not s… | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.20 |
| battActualCapacity The current maximum charge capacity of this battery. If the hardware
does not support periodic life testing, this will return the same
value as battDesignCapacity | column | milliamp hours SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.21 |
| battAge Specifies the current age of the battery as a percentage of its design
capacity. This value could be calculated by dividing battActualCapacity
by battDesignCapacity (however, thi… | column | percent Unsigned32 | .1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.22 |
| battNextLifeTest Returns/specifies the date and time of the next life test (mmddyyyy hh:mm:ss)
for the specified pack. If the charger does not support periodic life
testing then this object will … | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.23 |
| battDischargeTable Returns the full discharge table for the specified battery as a comma-delimited string | column | OctetString | .1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.24 |
| battCompressedDischargeTable Returns the compressed discharge table from the specified battery | column | OctetString | .1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.25 |
| battInvalidateNonVolSlot Invalidates the specified non-vol slot | column | Unsigned32 | .1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.26 |
| battMaximumVoltage The voltage at which this battery is considered to be fully charged.
Note that if battChargerMaximumCharge is set to less than 100%, the
battery will never be charged to this v… | column | millivolts SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.3 |
| battMinimumVoltage The voltage at which this battery is considered to be fully
discharged. | column | millivolts SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.4 |
| battMeasuredVoltage The most recently measured voltage of this battery. | column | millivolts SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.5 |
| battIsValid Indicates whether this battery is considered valid by the battery
charger. A value of false(2) here indicates some kind of failure
with this battery. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.6 |
| battIsSelected Indicates whether this battery is currently selected for charging or
discharging. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.7 |
| battEstimatedMinutesRemaining An estimate of the time to depletion of this battery's charge
under the present load conditions if the utility power
is off and remains off, or if it were to be lost and
remain of… | column | minutes UPS-MIBPositiveInteger | .1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.8 |
| battEstimatedChargeRemaining An estimate of this battery's charge remaining expressed
as a percent of full charge. | column | percent Integer32 | .1.3.6.1.4.1.4413.2.2.2.1.10.1.1.1.9 |