.1.3.6.1.4.1.45.5.29.1.2 · 1 row entry · 28 columns
This table contains information about DDI SFPs.  Entries will
exist in this table only for DDI SFP ports.
bsDdiSfpEntry entry .1.3.6.1.4.1.45.5.29.1.2.1
SFF interface settings.
Indexes
bsDdiSfpIfIndex
Column Syntax OID
bsDdiSfpIfIndex
Identifies the ifIndex of the SFF port.
IF-MIBInterfaceIndex
Textual Convention: IF-MIBInterfaceIndex Integer32
Type Constraints:
range: 1..2147483647
.1.3.6.1.4.1.45.5.29.1.2.1.1
bsDdiSfpCalibration
This object indicates whether the actual values read from EEPROM
internally within an implementation are already calibrated to the
appropriate units (Volts, mA, dB, etc), or whether these values
are first converted to a…
Enumeration
Enumerated Values:
1internal
2external
.1.3.6.1.4.1.45.5.29.1.2.1.2
bsDdiSfpRxPowerMeasurement
This object indicates the measurement type used for the received
power. A value of oma(1) indicates Optical Modulation Amplitude
(OMA).
Enumeration
Enumerated Values:
1oma
2averagePower
.1.3.6.1.4.1.45.5.29.1.2.1.3
bsDdiSfpTempValue
The actual temperature value, measured in 1/10000 Celsius.
Integer32
Constraints:
range: -1280000-1280000
.1.3.6.1.4.1.45.5.29.1.2.1.4
bsDdiSfpTempLowAlarmThreshold
The low alarm temperature threshold, measure in 1/10000 Celsius.
Integer32
Constraints:
range: -1280000-1280000
.1.3.6.1.4.1.45.5.29.1.2.1.5
bsDdiSfpTempLowWarnThreshold
The low warn temperature threshold, measure in 1/10000 Celsius.
Integer32
Constraints:
range: -1280000-1280000
.1.3.6.1.4.1.45.5.29.1.2.1.6
bsDdiSfpTempHighAlarmThreshold
The high alarm temperature threshold, measure in 1/10000 Celsius.
Integer32
Constraints:
range: -1280000-1280000
.1.3.6.1.4.1.45.5.29.1.2.1.7
bsDdiSfpTempHighWarnThreshold
The high warn temperature threshold, measure in 1/10000 Celsius.
Integer32
Constraints:
range: -1280000-1280000
.1.3.6.1.4.1.45.5.29.1.2.1.8
bsDdiSfpVoltageValue
The actual voltage value, measured in 1/10000 volts.
Integer32
Constraints:
range: 0-65500
.1.3.6.1.4.1.45.5.29.1.2.1.9
bsDdiSfpVoltageLowAlarmThreshold
The low alarm voltage threshold, measured in 1/10000 volts.
Integer32
Constraints:
range: 0-65500
.1.3.6.1.4.1.45.5.29.1.2.1.10
bsDdiSfpVoltageLowWarnThreshold
The low warn voltage threshold, measured in 1/10000 volts.
Integer32
Constraints:
range: 0-65500
.1.3.6.1.4.1.45.5.29.1.2.1.11
bsDdiSfpVoltageHighAlarmThreshold
The high alarm voltage threshold, measured in 1/10000 volts.
Integer32
Constraints:
range: 0-65500
.1.3.6.1.4.1.45.5.29.1.2.1.12
bsDdiSfpVoltageHighWarnThreshold
The high warn voltage threshold, measured in 1/10000 volts.
Integer32
Constraints:
range: 0-65500
.1.3.6.1.4.1.45.5.29.1.2.1.13
bsDdiSfpBiasValue
The actual bias value, measured in 1/10000 mA.
Integer32
Constraints:
range: 0-1280000
.1.3.6.1.4.1.45.5.29.1.2.1.14
bsDdiSfpBiasLowAlarmThreshold
The low alarm bias threshold, measured in 1/10000 mA.
Integer32
Constraints:
range: 0-1280000
.1.3.6.1.4.1.45.5.29.1.2.1.15
bsDdiSfpBiasLowWarnThreshold
The low warn bias threshold, measured in 1/10000 mA.
Integer32
Constraints:
range: 0-1280000
.1.3.6.1.4.1.45.5.29.1.2.1.16
bsDdiSfpBiasHighAlarmThreshold
The high alarm bias threshold, measured in 1/10000 mA.
Integer32
Constraints:
range: 0-1280000
.1.3.6.1.4.1.45.5.29.1.2.1.17
bsDdiSfpBiasHighWarnThreshold
The high warn bias threshold, measured in 1/10000 mA.
Integer32
Constraints:
range: 0-1280000
.1.3.6.1.4.1.45.5.29.1.2.1.18
bsDdiSfpTxPowerValue
The actual transmit power value, measured in 1/10000 dBm.
Integer32
Constraints:
range: -400000-83000
.1.3.6.1.4.1.45.5.29.1.2.1.19
bsDdiSfpTxPowerLowAlarmThreshold
The low alarm transmit power threshold, measured in 1/10000 dBm.
Integer32
Constraints:
range: -400000-83000
.1.3.6.1.4.1.45.5.29.1.2.1.20
bsDdiSfpTxPowerLowWarnThreshold
The low warn transmit power threshold, measured in 1/10000 dBm.
Integer32
Constraints:
range: -400000-83000
.1.3.6.1.4.1.45.5.29.1.2.1.21
bsDdiSfpTxPowerHighAlarmThreshold
The high alarm transmit power threshold, measured in 1/10000 dBm.
Integer32
Constraints:
range: -400000-83000
.1.3.6.1.4.1.45.5.29.1.2.1.22
bsDdiSfpTxPowerHighWarnThreshold
The high warn transmit power threshold, measured in 1/10000 dBm.
Integer32
Constraints:
range: -400000-83000
.1.3.6.1.4.1.45.5.29.1.2.1.23
bsDdiSfpRxPowerValue
The actual receive power value, measured in 1/10000 dBm.
Integer32
Constraints:
range: -400000-83000
.1.3.6.1.4.1.45.5.29.1.2.1.24
bsDdiSfpRxPowerLowAlarmThreshold
The low alarm receive power threshold, measured in 1/10000 dBm.
Integer32
Constraints:
range: -400000-83000
.1.3.6.1.4.1.45.5.29.1.2.1.25
bsDdiSfpRxPowerLowWarnThreshold
The low warn receive power threshold, measured in 1/10000 dBm.
Integer32
Constraints:
range: -400000-83000
.1.3.6.1.4.1.45.5.29.1.2.1.26
bsDdiSfpRxPowerHighAlarmThreshold
The high alarm receive power threshold, measured in 1/10000 dBm.
Integer32
Constraints:
range: -400000-83000
.1.3.6.1.4.1.45.5.29.1.2.1.27
bsDdiSfpRxPowerHighWarnThreshold
The high warn receive power threshold, measured in 1/10000 dBm.
Integer32
Constraints:
range: -400000-83000
.1.3.6.1.4.1.45.5.29.1.2.1.28