bsDdiSfpTempHighWarnThreshold
BAY-STACK-SFF-MIB ·
.1.3.6.1.4.1.45.5.29.1.2.1.8
Object
column
Integer32
The high warn temperature threshold, measure in 1/10000 Celsius.
Context
- MIB
- BAY-STACK-SFF-MIB
- OID
.1.3.6.1.4.1.45.5.29.1.2.1.8- Type
- column
- Access
- readonly
- Status
- current
- Parent
- bsDdiSfpEntry
- Table
- bsDdiSfpTable
- Siblings
- 27
Syntax
Integer32
Values & Constraints
Object Constraints
range: -1280000-1280000
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| bsDdiSfpIfIndex Identifies the ifIndex of the SFF port. | column | IF-MIBInterfaceIndex | .1.3.6.1.4.1.45.5.29.1.2.1.1 |
| bsDdiSfpVoltageLowAlarmThreshold The low alarm voltage threshold, measured in 1/10000 volts. | column | Integer32 | .1.3.6.1.4.1.45.5.29.1.2.1.10 |
| bsDdiSfpVoltageLowWarnThreshold The low warn voltage threshold, measured in 1/10000 volts. | column | Integer32 | .1.3.6.1.4.1.45.5.29.1.2.1.11 |
| bsDdiSfpVoltageHighAlarmThreshold The high alarm voltage threshold, measured in 1/10000 volts. | column | Integer32 | .1.3.6.1.4.1.45.5.29.1.2.1.12 |
| bsDdiSfpVoltageHighWarnThreshold The high warn voltage threshold, measured in 1/10000 volts. | column | Integer32 | .1.3.6.1.4.1.45.5.29.1.2.1.13 |
| bsDdiSfpBiasValue The actual bias value, measured in 1/10000 mA. | column | Integer32 | .1.3.6.1.4.1.45.5.29.1.2.1.14 |
| bsDdiSfpBiasLowAlarmThreshold The low alarm bias threshold, measured in 1/10000 mA. | column | Integer32 | .1.3.6.1.4.1.45.5.29.1.2.1.15 |
| bsDdiSfpBiasLowWarnThreshold The low warn bias threshold, measured in 1/10000 mA. | column | Integer32 | .1.3.6.1.4.1.45.5.29.1.2.1.16 |
| bsDdiSfpBiasHighAlarmThreshold The high alarm bias threshold, measured in 1/10000 mA. | column | Integer32 | .1.3.6.1.4.1.45.5.29.1.2.1.17 |
| bsDdiSfpBiasHighWarnThreshold The high warn bias threshold, measured in 1/10000 mA. | column | Integer32 | .1.3.6.1.4.1.45.5.29.1.2.1.18 |
| bsDdiSfpTxPowerValue The actual transmit power value, measured in 1/10000 dBm. | column | Integer32 | .1.3.6.1.4.1.45.5.29.1.2.1.19 |
| bsDdiSfpCalibration This object indicates whether the actual values read from EEPROM
internally within an implementation are already calibrated to the
appropriate units (Volts, mA, dB, etc), or wheth… | column | Enumeration | .1.3.6.1.4.1.45.5.29.1.2.1.2 |
| bsDdiSfpTxPowerLowAlarmThreshold The low alarm transmit power threshold, measured in 1/10000 dBm. | column | Integer32 | .1.3.6.1.4.1.45.5.29.1.2.1.20 |
| bsDdiSfpTxPowerLowWarnThreshold The low warn transmit power threshold, measured in 1/10000 dBm. | column | Integer32 | .1.3.6.1.4.1.45.5.29.1.2.1.21 |
| bsDdiSfpTxPowerHighAlarmThreshold The high alarm transmit power threshold, measured in 1/10000 dBm. | column | Integer32 | .1.3.6.1.4.1.45.5.29.1.2.1.22 |
| bsDdiSfpTxPowerHighWarnThreshold The high warn transmit power threshold, measured in 1/10000 dBm. | column | Integer32 | .1.3.6.1.4.1.45.5.29.1.2.1.23 |
| bsDdiSfpRxPowerValue The actual receive power value, measured in 1/10000 dBm. | column | Integer32 | .1.3.6.1.4.1.45.5.29.1.2.1.24 |
| bsDdiSfpRxPowerLowAlarmThreshold The low alarm receive power threshold, measured in 1/10000 dBm. | column | Integer32 | .1.3.6.1.4.1.45.5.29.1.2.1.25 |
| bsDdiSfpRxPowerLowWarnThreshold The low warn receive power threshold, measured in 1/10000 dBm. | column | Integer32 | .1.3.6.1.4.1.45.5.29.1.2.1.26 |
| bsDdiSfpRxPowerHighAlarmThreshold The high alarm receive power threshold, measured in 1/10000 dBm. | column | Integer32 | .1.3.6.1.4.1.45.5.29.1.2.1.27 |
| bsDdiSfpRxPowerHighWarnThreshold The high warn receive power threshold, measured in 1/10000 dBm. | column | Integer32 | .1.3.6.1.4.1.45.5.29.1.2.1.28 |
| bsDdiSfpRxPowerMeasurement This object indicates the measurement type used for the received
power. A value of oma(1) indicates Optical Modulation Amplitude
(OMA). | column | Enumeration | .1.3.6.1.4.1.45.5.29.1.2.1.3 |
| bsDdiSfpTempValue The actual temperature value, measured in 1/10000 Celsius. | column | Integer32 | .1.3.6.1.4.1.45.5.29.1.2.1.4 |
| bsDdiSfpTempLowAlarmThreshold The low alarm temperature threshold, measure in 1/10000 Celsius. | column | Integer32 | .1.3.6.1.4.1.45.5.29.1.2.1.5 |
| bsDdiSfpTempLowWarnThreshold The low warn temperature threshold, measure in 1/10000 Celsius. | column | Integer32 | .1.3.6.1.4.1.45.5.29.1.2.1.6 |
| bsDdiSfpTempHighAlarmThreshold The high alarm temperature threshold, measure in 1/10000 Celsius. | column | Integer32 | .1.3.6.1.4.1.45.5.29.1.2.1.7 |
| bsDdiSfpVoltageValue The actual voltage value, measured in 1/10000 volts. | column | Integer32 | .1.3.6.1.4.1.45.5.29.1.2.1.9 |