ADTRAN-TAESCUAUTOUPGRADE-MIB

        This MIB defines the objects for the genescu MIB.
    
adTAeSCUAutoUpgradeMgmt 1.3.6.1.4.1.664.2.241.11
Imported Objects
ADTRAN-GENSLOT-MIB adGenSlotInfoIndex adGenSlotProdName adGenSlotProdSwVersion
ADTRAN-GENTRAPINFORM-MIB adTrapInformSeqNum
ADTRAN-TAeSCU-MIB adTAeSCU adTAeSCUmg adTAeSCUmgNotificationEvents
SNMPv2-MIB sysName
SNMPv2-SMI Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-IDENTITY OBJECT-TYPE
SNMPv2-TC DisplayString
Objects (14)
adTAeSCUAutoUpgradeMgmt .1.3.6.1.4.1.664.2.241.11
adTAeScuAutoUpgradeInitiate r/w Enumeration .1.3.6.1.4.1.664.2.241.11.1
adTAeSCUAutoUpgradeStatusTable .1.3.6.1.4.1.664.2.241.11.10
adTAeSCUAutoUpgradeStatusEntry ADTRAN-GENSLOT-MIBadGenSlotInfoIndex .1.3.6.1.4.1.664.2.241.11.10.1
adTAeScuAutoUpgradeStatus OctetStringBRIDGE-MIBdot1dBasePort .1.3.6.1.4.1.664.2.241.11.10.1.1
adTAeScuAutoUpgradeSWVerErrLevel r/w Enumeration .1.3.6.1.4.1.664.2.241.11.11
adTAeScuAutoUpgradeCancel r/w Enumeration .1.3.6.1.4.1.664.2.241.11.2
adTAeScuAutoUpgradeRetries r/w Integer32 .1.3.6.1.4.1.664.2.241.11.3
adTAeScuAutoUpgradeRefeshInterval r/w Integer32 .1.3.6.1.4.1.664.2.241.11.4
adTAeScuAutoUpgradeMode r/w Enumeration .1.3.6.1.4.1.664.2.241.11.5
adTAeScuAutoUpgradeConfigFilename r/w OctetString .1.3.6.1.4.1.664.2.241.11.6
adTAeScuAutoUpgradeBasePath r/w OctetString .1.3.6.1.4.1.664.2.241.11.7
adTAeScuAutoUpgradeInvalidate r/w Enumeration .1.3.6.1.4.1.664.2.241.11.8
adTAeScuAutoUpgradeSystemRelease SNMPv2-TCDisplayString .1.3.6.1.4.1.664.2.241.11.9
Notifications / Traps (8)
NameOIDDescription
adTAeSCUAutoUpgradeConfigChanged
ADTRAN-GENTRAPINFORM-MIBadTrapInformSeqNum SNMPv2-MIBsysName
.1.3.6.1.4.1.664.1.241.0.24150
This trap is used to indicate that a change in the Auto
Upgrade configuration file has been detected.
adTAeSCUAutoUpgradeInvalidConfigFile
ADTRAN-GENTRAPINFORM-MIBadTrapInformSeqNum SNMPv2-MIBsysName
.1.3.6.1.4.1.664.1.241.0.24152
This trap is used to indicate that a problem with the
Auto Upgrade configuration file has been detected, such
as a TFTP error while retrieving the file, or an error
during parsing.  The EMS should perform a 'get' on the
AdTAeScuAutoUpgradeStatus OID for further information
regarding the error condition.
adTAeSCUAutoUpgradeModuleUpgradeStarted
ADTRAN-GENTRAPINFORM-MIBadTrapInformSeqNum SNMPv2-MIBsysName ADTRAN-GENSLOT-MIBadGenSlotInfoIndex
.1.3.6.1.4.1.664.1.241.0.24154
This trap is used to indicate that a module upgrade
operation has been started.
adTAeSCUAutoUpgradeModuleUpgradeCompleted
ADTRAN-GENTRAPINFORM-MIBadTrapInformSeqNum SNMPv2-MIBsysName ADTRAN-GENSLOT-MIBadGenSlotInfoIndex
.1.3.6.1.4.1.664.1.241.0.24156
This trap is used to indicate that a module upgrade
operation has successfully completed.
adTAeSCUAutoUpgradeModuleUpgradeFailed .1.3.6.1.4.1.664.1.241.0.24158
This trap is used to indicate that a module upgrade
operation has failed.  The EMS should perform a 'get'
on the AdTAeScuAutoUpgradeStatus OID for further
information regarding the error condition.
adTAeSCUAutoUpgradeUnknownModule
ADTRAN-GENTRAPINFORM-MIBadTrapInformSeqNum SNMPv2-MIBsysName ADTRAN-GENSLOT-MIBadGenSlotInfoIndex
.1.3.6.1.4.1.664.1.241.0.24160
This trap is used to indicate that a module
is not present in the Auto Upgrade configuration
file.  This module cannot be upgrade by the Auto
Upgrade system.
adTAAUSoftwareVerErrorClear
ADTRAN-GENTRAPINFORM-MIBadTrapInformSeqNum SNMPv2-MIBsysName ADTRAN-GENSLOT-MIBadGenSlotInfoIndex ADTRAN-GENSLOT-MIBadGenSlotProdName ADTRAN-GENSLOT-MIBadGenSlotProdSwVersion adTAeScuAutoUpgradeSWVerErrLevel
.1.3.6.1.4.1.664.1.241.0.24166
Auto Upgrade Software Version Error
adTAAUSoftwareVerErrorActive
ADTRAN-GENTRAPINFORM-MIBadTrapInformSeqNum SNMPv2-MIBsysName ADTRAN-GENSLOT-MIBadGenSlotInfoIndex ADTRAN-GENSLOT-MIBadGenSlotProdName ADTRAN-GENSLOT-MIBadGenSlotProdSwVersion adTAeScuAutoUpgradeSWVerErrLevel
.1.3.6.1.4.1.664.1.241.0.24167
Auto Upgrade Software Version Error