zhoneVdslLineConfDownPboControl
ZhoneVdsl-MIB ·
.1.3.6.1.4.1.5504.5.13.1.1.11.1.24
Object
column
r/w
Enumeration
Downstream power backoff (PBO) control for this
line. For transceivers which do not support downstream
PBO control, this object MUST be fixed at disabled(1).
If auto(2) is selected, the transceiver will automatically
adjust the power backoff. If manual(3) is selected,
then the transceiver will use the value from
zhoneVdslLineConfDownPboLevel.
Context
- MIB
- ZhoneVdsl-MIB
- OID
.1.3.6.1.4.1.5504.5.13.1.1.11.1.24- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- zhoneVdslLineConfProfileEntry
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | disabled |
2 | auto |
3 | manual |