zhoneVdslLineAlarmConfThresh15MinLols
ZhoneVdsl-MIB ·
.1.3.6.1.4.1.5504.5.13.1.1.20.1.5
Object
column
r/w
seconds Integer32
This object configures the threshold for the number of loss of link seconds (LOLs) within any given 15-minute performance data collection interval. If the value of loss of link seconds in a particular 15-minute collection interval reaches/exceeds this value, a zhoneVdslPerfLolsThreshNotification notification will be generated. No more than one notification will be sent per interval.
Context
- MIB
- ZhoneVdsl-MIB
- OID
.1.3.6.1.4.1.5504.5.13.1.1.20.1.5- Type
- column
- Access
- readwrite
- Status
- current
- Units
- seconds
- Parent
- zhoneVdslLineAlarmConfProfileEntry
Syntax
seconds Integer32
Values & Constraints
Object Constraints
range: 0-900