eventSeqNum
ZYXEL-ves1608FE57-MIB ·
.1.3.6.1.4.1.890.1.5.12.43.26.1.1.1.1
Object
column
SNMPv2-SMIInteger32
This variable represents the sequence number of an event.
Sequence number is incremented monotonically starting
from 0 until it reaches its maximum and wraps around back
to 0.
Sequence number is incremented when
- the state of a normal type fault is set on (the same sequence
number is present in the events table as well as in the trap
that is sent to notify about the fault on event)
- delta event occurs (sequence number present in trap message)
- the state of a normal type fault is set off (sequence number
present in trap that is sent to notify for clearing).
Context
- MIB
- ZYXEL-ves1608FE57-MIB
- OID
.1.3.6.1.4.1.890.1.5.12.43.26.1.1.1.1- Type
- column
- Access
- readonly
- Status
- current
- Parent
- eventEntry
- Table
- eventTable
- Siblings
- 10
Syntax
SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| eventServAffective This variable indicates whether the event is service affective or not | column | EventServiceAffective | .1.3.6.1.4.1.890.1.5.12.43.26.1.1.1.10 |
| eventInstanceIdNumber This variable represents the InstanceId of a particular
event in the event current table. In brief the instanceId
refers to the sub-component generating this event in the
syste… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.890.1.5.12.43.26.1.1.1.11 |
| eventEventId This variable represents the event ID which uniquely
identifies the event in the entire system. | column | EventIdNumber | .1.3.6.1.4.1.890.1.5.12.43.26.1.1.1.2 |
| eventName This variable represents the name of the event, for
example 'Ethernet Link Down' | column | OctetString | .1.3.6.1.4.1.890.1.5.12.43.26.1.1.1.3 |
| eventInstanceType This variable represents the type of InstanceId of a
particular event in the event table. In brief
the instanceType refers to the type of sub-component
generating this event in th… | column | InstanceType | .1.3.6.1.4.1.890.1.5.12.43.26.1.1.1.4 |
| eventInstanceId This variable represents the InstanceId of a particular
event in the event current table. In brief the instanceId
refers to the sub-component generating this event in the
system, … | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.890.1.5.12.43.26.1.1.1.5 |
| eventInstanceName This variable is mainly used to store additional information
about the sub-component that is generating an event. For
example this field may specify what cooling fan is faulty.
… | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.890.1.5.12.43.26.1.1.1.6 |
| eventSeverity This variable dictates the urgency of action when a event
occurs. There are four severity levels - Critical, Major,
Minor, and Informational. Critical events are those, which
req… | column | EventSeverity | .1.3.6.1.4.1.890.1.5.12.43.26.1.1.1.7 |
| eventSetTime This table contains only normal events and this variable
represents the time when the event become active, i.e. the
number of seconds since Jan 1, 1970 12:00AM. | column | UtcTimeStamp | .1.3.6.1.4.1.890.1.5.12.43.26.1.1.1.8 |
| eventDescription This variable contains a description of the event and reasons
behind the event. This is a free format alpha-numeric string
that is set by the entity generating this event. This va… | column | OctetString | .1.3.6.1.4.1.890.1.5.12.43.26.1.1.1.9 |