vdsl2LineProfSosTimeDs
ZYXEL-IES5000-MIB ·
.1.3.6.1.4.1.890.1.5.13.5.9.11.7.1.7
Object
The parameter SOS-TIME-ds is used in the specification of the receiver initiated SOS
(see 13.4.3/G.993.2). If the value of this parameter is not zero, the standard SOS
triggering criteria are enabled, and the value corresponds with duration of the time
window used in the standard SOS triggering criteria in the downstream direction.
See G.993.2 for detailed usage rules.
The special value zero indicates that the standard SOS triggering criteria are disabled,
i.e., vendor-discretionary values may be used instead of the values configured in the MIB
for the following parameters: SOS-NTONES-ds, SOS-CRC-ds, SOS-TIME-ds.
This parameter applies in the downstream direction. The valid range of non-zero values
is from 64 ms to 16320 ms in steps of 64 ms.
Context
- MIB
- ZYXEL-IES5000-MIB
- OID
.1.3.6.1.4.1.890.1.5.13.5.9.11.7.1.7- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- vdsl2LineConfProfileExtendedEntry
- Table
- vdsl2LineConfProfileExtendedTable
- Siblings
- 22
Syntax
SNMPv2-SMIUnsigned32
- Source
- SNMPv2-SMIUnsigned32
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| vdsl2LineProfDpboEPsdID standard psd shape id for psd toolbox | column | Enumeration | .1.3.6.1.4.1.890.1.5.13.5.9.11.7.1.1 |
| vdsl2LineProfSosCrcUs This parameter is defined as the minimum number of normalized CRC anomalies received
in SOS-TIME-ds seconds in order to arm the second sub condition of the standard SOS
triggeri… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.890.1.5.13.5.9.11.7.1.10 |
| vdsl2LineProfSosNToneDs This parameter is defined as the minimum percentage of tones in the downstream
MEDLEY SET that must be degraded in order to arm the first sub-condition of the
standard SOS trigg… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.890.1.5.13.5.9.11.7.1.11 |
| vdsl2LineProfSosNToneUs This parameter is defined as the minimum percentage of tones in the downstream
MEDLEY SET that must be degraded in order to arm the first sub-condition of the
standard SOS trigg… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.890.1.5.13.5.9.11.7.1.12 |
| vdsl2LineProfSosMaxDs This parameter is used in G.993.2 de-activation (see 12.1.4/G.993.2). If the number
of successful SOS procedures in the downstream direction performed within a 120-second
interv… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.890.1.5.13.5.9.11.7.1.13 |
| vdsl2LineProfSosMaxUs This parameter is used in G.993.2 de-activation (see 12.1.4/G.993.2). If the number
of successful SOS procedures in the downstream direction performed within a 120-second
interv… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.890.1.5.13.5.9.11.7.1.14 |
| vdsl2LineProfRocEnableDs Enable the robust overhead channel. | column | Enumeration | .1.3.6.1.4.1.890.1.5.13.5.9.11.7.1.17 |
| vdsl2LineProfRocEnableUs Enable the robust overhead channel. | column | Enumeration | .1.3.6.1.4.1.890.1.5.13.5.9.11.7.1.18 |
| vdsl2LineProfRocSnrmDs The parameter is defined as the SNR margin offset for the ROC channel in the downstream
direction. The parameter is used in the specification of the channel initialization
polic… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.890.1.5.13.5.9.11.7.1.19 |
| vdsl2LineProfBitSwapDs | column | Enumeration | .1.3.6.1.4.1.890.1.5.13.5.9.11.7.1.2 |
| vdsl2LineProfRocSnrmUs The parameter is defined as the SNR margin offset for the ROC channel in the downstream
direction. The parameter is used in the specification of the channel initialization
polic… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.890.1.5.13.5.9.11.7.1.20 |
| vdsl2LineProfRocMinInpDs This parameter contains the minimum impulse noise protection to apply on the ROC in the
downstream direction. The minimum impulse noise protection is an integer ranging from
0 t… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.890.1.5.13.5.9.11.7.1.21 |
| vdsl2LineProfRocMinInpUs This parameter contains the minimum impulse noise protection to apply on the ROC in the
downstream direction. The minimum impulse noise protection is an integer ranging from
0 t… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.890.1.5.13.5.9.11.7.1.22 |
| vdsl2LineProfDpboType | column | Enumeration | .1.3.6.1.4.1.890.1.5.13.5.9.11.7.1.23 |
| vdsl2LineProfDpboEselMin | column | 0.5 dB Integer32 | .1.3.6.1.4.1.890.1.5.13.5.9.11.7.1.24 |
| vdsl2LineProfCompatible Compatible to spectrum usage of adsl2 or adsl2+ line. | column | Enumeration | .1.3.6.1.4.1.890.1.5.13.5.9.11.7.1.25 |
| vdsl2LineProfBitSwapUs | column | Enumeration | .1.3.6.1.4.1.890.1.5.13.5.9.11.7.1.3 |
| vdsl2LineProfProfileName | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.890.1.5.13.5.9.11.7.1.4 |
| vdsl2LineProfDynamicDepthEnableDs Enable the dynamic change of interleave depth. | column | Enumeration | .1.3.6.1.4.1.890.1.5.13.5.9.11.7.1.5 |
| vdsl2LineProfDynamicDepthEnableUs Enable the dynamic change of interleave depth. | column | Enumeration | .1.3.6.1.4.1.890.1.5.13.5.9.11.7.1.6 |
| vdsl2LineProfSosTimeUs The parameter SOS-TIME-u s is used in the specification of the receiver initiated SOS
(see 13.4.3/G.993.2). If the value of this parameter is not zero, the standard SOS
triggeri… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.890.1.5.13.5.9.11.7.1.8 |
| vdsl2LineProfSosCrcDs This parameter is defined as the minimum number of normalized CRC anomalies received
in SOS-TIME-ds seconds in order to arm the second sub condition of the standard SOS