zxAnXdsl2LConfSosTimeWindowDs
ZTE-AN-XDSL2-MIBII ·
.1.3.6.1.4.1.3902.1015.1001.1.3.21.1.2
Object
column
r/w
ms Integer32
The parameter SOS-TIME-ds is used in the specification of the receiver initiated SOS(see 13.4.3/G.993.2). If the value of this parameter is not zero, the standard SOS triggering criteria are enabled, and the value corresponds with duration of the time window used in the standard SOS triggering criteria in the downstream direction. See G.993.2 for detailed usage rules. The special value zero indicates that the standard SOS triggering criteria are disabled, i.e., vendordiscretionary values may be used instead of the values configured in the MIB for the following parameters: SOS-NTONES-ds, SOS-CRC-ds, SOS-TIME-ds. This parameter applies in the downstream direction. The valid range of non-zero values is from 64 ms to 16320 ms in steps of 64 ms.
Context
- MIB
- ZTE-AN-XDSL2-MIBII
- OID
.1.3.6.1.4.1.3902.1015.1001.1.3.21.1.2- Type
- column
- Access
- readwrite
- Status
- current
- Units
- ms
- Parent
- zxAnXdsl2SosConfPrfEntry
Syntax
ms Integer32
Values & Constraints
Object Constraints
range: 0-0
range: 64-16320