zxAnLoopbackDetectActiveInterval

ZTE-AN-LOOPBACKDETECT-MIB · .1.3.6.1.4.1.3902.1082.80.20.1.5

Object

scalar r/w secondsInteger32
The interval of the active loopback detection.
For C600 Series, the default value is 30.
For non-C600 Series, the default value is 120.

Context

MIB
ZTE-AN-LOOPBACKDETECT-MIB
OID
.1.3.6.1.4.1.3902.1082.80.20.1.5
Type
scalar
Access
readwrite
Status
current
Units
seconds
Parent
zxAnLoopbackDetectGlobalObjects

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'ZTE-AN-LOOPBACKDETECT-MIB' -M '/opt/observium/mibs/zte-ng:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ZTE-AN-LOOPBACKDETECT-MIB::zxAnLoopbackDetectActiveInterval.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'ZTE-AN-LOOPBACKDETECT-MIB' -M '/opt/observium/mibs/zte-ng:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'ZTE-AN-LOOPBACKDETECT-MIB::zxAnLoopbackDetectActiveInterval'

Syntax

secondsInteger32

Values & Constraints

Object Constraints
range: 1-900