s100ThermoATemperature

ZHONE-SECHTOR100-MIB · .1.3.6.1.4.1.5504.2.4.1.1.6

Object

scalar deprecated Integer32
The temperature in degrees Celsius read by the IC 
thermometer sensor A on the PCB board. It is effectively
the internal ambient temperature inside the enclosure
where thermometer A is located.
          
The valid temperature range for the thermometer is
-55..125 degrees Celsius.

Context

MIB
ZHONE-SECHTOR100-MIB
OID
.1.3.6.1.4.1.5504.2.4.1.1.6
Type
scalar
Access
readonly
Status
deprecated
Parent
sechtor100Environment

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'ZHONE-SECHTOR100-MIB' -M '/opt/observium/mibs/zhone:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ZHONE-SECHTOR100-MIB::s100ThermoATemperature.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'ZHONE-SECHTOR100-MIB' -M '/opt/observium/mibs/zhone:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'ZHONE-SECHTOR100-MIB::s100ThermoATemperature'

Syntax

Integer32

Values & Constraints

Object Constraints
range: -55-125