ZHONE-SECHTOR100-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
1
Rows
1
Columns
12
sechtor100ConfigTable
table.1.3.6.1.4.1.5504.2.4.1.3
·
1 row entry
·
12 columns
Uses the zhone variant from
Command help
/opt/observium/mibs/zhone.
Walk sechtor100ConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ZHONE-SECHTOR100-MIB' -M '/opt/observium/mibs/zhone:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ZHONE-SECHTOR100-MIB::sechtor100ConfigTable'
This table contains redundancy variables and environmental
variables for monitoring fans and thermometers.
For redundancy, the peer MAC address is maintained in this
table. Also, one variable specifies whether redundancy is
enabled or not.
There are two thermometers on the Sechtor 100 board. In this
MIB, thermometers 'A' and 'B' are used to differentiate
these two thermometers:
Thermometer A - the thermometer located near the 750
processor. It is expected that this thermometer have a higher
temperature reading than thermometer B because of the heat
generated by the processor. It is recommended that a higher
upper threshold is set for this thermometer.
Thermometer B - the thermometer located near the outlet on
the right side of the Sechtor 100 board.
The profile for this table will be auto-created as 1/1 with
the sechtor100RedundancyEnable variable set to FALSE.
This profile should not be deleted except for the following
two cases:
1) When a unit operating in simplex mode is intended to be used
in duplex mode as the slot 2 of the redundant system. The
user needs to create a 1/2 profile.
2) The unit configured as slot 2 of a redundant system is intended
to be used in simplex mode. Then the 1/2 profile should be
deleted and replaced with a 1/1 profile.
An entry in the sechtor100ConfigTable.
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
This is the Mac address of the peer s100 unit.
|
SNMPv2-TCMacAddressr/w Type Constraints: range: 6Description: Represents an 802 MAC address represented in the `canonical' order defined by IEEE 802.1a, i.e., as if it were transmitted least significant bit first, even though 802.5 (in contrast to other 802.x protocols) requires M… |
.1.3.6.1.4.1.5504.2.4.1.3.1.1 |
||||||
|
Whether or not the redundancy functionality has been enabled.
If this value is false, redundancy is not enable. |
SNMPv2-TCTruthValuer/w Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.5504.2.4.1.3.1.2 |
||||||
|
This variable describes the working status of the four fans
for the Sechtor 100. If any one of the four fans is not running correctly, this variable shows 'fanFailure'. When all the fans are working, the value of this v… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.5504.2.4.1.3.1.3 |
||||||
|
This variable specifies the upper threshold for thermometer
A in degrees Celsius. When s100ThermoATemperature is above this value, s100ThermoAOperationalStatus would be 'overUpperThreshold' and a trap will be generated.… |
Integer32r/w Constraints: range: 45-80 |
.1.3.6.1.4.1.5504.2.4.1.3.1.4 |
||||||
|
This variable specifies the upper threshold for thermometer
B in degrees Celsius. When s100ThermoBTemperature is above this value, s100ThermoBOperationalStatus would be 'overUpperThreshold' and a trap will be generated.… |
Integer32r/w Constraints: range: 45-80 |
.1.3.6.1.4.1.5504.2.4.1.3.1.5 |
||||||
|
This variable specifies the lower threshold for thermometer
A in degrees Celsius. When s100ThermoATemperature is below this value, s100ThermoAOperationalStatus would be 'belowLowerThreshold' and a trap will be generated… |
Integer32r/w Constraints: range: -10-5 |
.1.3.6.1.4.1.5504.2.4.1.3.1.6 |
||||||
|
This variable specifies the lower threshold for thermometer
B in degrees Celsius. When s100ThermoATemperature is below this value, s100ThermoBOperationalStatus would be 'belowLowerThreshold' and a trap will be generated… |
Integer32r/w Constraints: range: -10-5 |
.1.3.6.1.4.1.5504.2.4.1.3.1.7 |
||||||
|
The temperature in degrees Celsius read by the IC
thermometer sensor A on the PCB board. It is effectively the internal ambient temperature inside the enclosure where thermometer A is located. The valid … |
Integer32 Constraints: range: -55-125 |
.1.3.6.1.4.1.5504.2.4.1.3.1.8 |
||||||
|
The temperature in degrees Celsius read by the IC
thermometer sensor B on the PCB board. It is effectively the internal ambient temperature inside the enclosure where thermometer B is located. … |
Integer32 Constraints: range: -55-125 |
.1.3.6.1.4.1.5504.2.4.1.3.1.9 |
||||||
|
The operational status indicator for thermometer A.
Valid values are: * withinOperationalRange - s100ThermoATemperature is within its lower and upper threshold range. * overUpperThreshold - s100ThermoAT… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.5504.2.4.1.3.1.10 |
||||||
|
The operational status indicator for thermometer B.
Valid values are: * withinOperationalRange - s100ThermoBTemperature is within its lower and upper threshold range. * overUpperThreshold - s100ThermoBT… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.5504.2.4.1.3.1.11 |
||||||
|
Used to control row creation and deletion.
A row in this table is created using a single SNMP SET request with varbinds for: a) sechtor100RowStatus set to'CreateAndGo', b) the following READ-CREATE obj… |
Zhone-TCZhoneRowStatusr/w Type Values:
|
.1.3.6.1.4.1.5504.2.4.1.3.1.12 |