xfPMSetThreshold15mRLTS2

XF-RADIOLINK-PTP-TERMINAL-MIB · .1.3.6.1.4.1.193.81.3.4.1.1.9.1.16

Object

column r/w Integer32
Received Level 2 Threshold Second (RLTS2) 15 minute.
Alarm Set threshold in number of seconds that
RF Input Power are allowed below the
RLTS2 Alarm Threshold for Minimum RF Input Power
in current 15 minute interval.
Always greater or equal to alarm Reset, xfPMResetThreshold15mRLTS2.

Context

MIB
XF-RADIOLINK-PTP-TERMINAL-MIB
OID
.1.3.6.1.4.1.193.81.3.4.1.1.9.1.16
Type
column
Access
readwrite
Status
current
Default
180
Parent
xfRLPMConfigEntry
Groups
1

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'XF-RADIOLINK-PTP-TERMINAL-MIB' -M '/opt/observium/mibs/ericsson:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'XF-RADIOLINK-PTP-TERMINAL-MIB::xfPMSetThreshold15mRLTS2'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'XF-RADIOLINK-PTP-TERMINAL-MIB' -M '/opt/observium/mibs/ericsson:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'XF-RADIOLINK-PTP-TERMINAL-MIB::xfPMSetThreshold15mRLTS2.<ifIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'XF-RADIOLINK-PTP-TERMINAL-MIB' -M '/opt/observium/mibs/ericsson:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'XF-RADIOLINK-PTP-TERMINAL-MIB::xfPMSetThreshold15mRLTS2'

Syntax

Integer32

Values & Constraints

Object Constraints
range: 1-900