wfCSMACDTurboBoflDebug

Wellfleet-CSMACD-MIB · .1.3.6.1.4.1.18.3.4.1.1.61

Object

column mandatory r/w Integer32
Special Turbo-BOFL debug mechanism to be used by Engineering
and Manufacturing only.
31-24 : TMO - period of breath (amount of time between
				 successive breaths of life)
23-16 : Number of packets per breath.
15-0  : Packet length in bytes - 22 bytes minimum.
All bits set to zero will disable this attribute.

Context

MIB
Wellfleet-CSMACD-MIB
OID
.1.3.6.1.4.1.18.3.4.1.1.61
Type
column
Access
readwrite
Status
mandatory
Parent
wfCSMACDEntry

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'Wellfleet-CSMACD-MIB' -M '/opt/observium/mibs/nortel:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Wellfleet-CSMACD-MIB::wfCSMACDTurboBoflDebug'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'Wellfleet-CSMACD-MIB' -M '/opt/observium/mibs/nortel:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Wellfleet-CSMACD-MIB::wfCSMACDTurboBoflDebug.<wfCSMACDSlot>.<wfCSMACDConnector>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'Wellfleet-CSMACD-MIB' -M '/opt/observium/mibs/nortel:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'Wellfleet-CSMACD-MIB::wfCSMACDTurboBoflDebug'

Syntax

Source
SNMPv2-SMIInteger32
Base type
Integer32

Values & Constraints

Type Constraints
range: -2147483648..2147483647