wwpOamErrFrameSecsSummaryThreshold

WWP-OAM-MIB · .1.3.6.1.4.1.6141.2.400.1.2.6.1.9

Object

column r/w errored frame seconds SNMPv2-SMIInteger32
The number of errored frame seconds that must occur for this
event to be triggered.  The default value is one errored frame
second.  
                              
If wwpOamErrFrameSecsSummaryThreshold frame errors occur
within a window of wwpOamErrFrameSecsSummaryWindow (in tenths
of seconds), an Event Notification OAMPDU should be generated
with an Errored Frame Seconds Summary Event TLV indicating the
threshold has been crossed in this window.

Context

MIB
WWP-OAM-MIB
OID
.1.3.6.1.4.1.6141.2.400.1.2.6.1.9
Type
column
Access
readwrite
Status
current
Units
errored frame seconds
Parent
wwpOamEventConfigEntry
Table
wwpOamEventConfigTable
Siblings
11

Syntax

errored frame seconds SNMPv2-SMIInteger32
Source
SNMPv2-SMIInteger32
Base type
Integer32

Values & Constraints

Type Constraints
range: -2147483648..2147483647

Related Objects