Ethernet OAM includes the ability to generate and receive
event notifications to indicate various link problems. This
table contains the mechanisms to configure the thresholds to
generate the standard Ethernet OAM events.
These events are:
- Errored Symbol Period Event. Generated when the number of
symbol errors exceeds a threshold within a given window
defined by a number of symbols (e.g. 1,000 symbols out of
1,000,000 had errors).
- Errored Frame Period Event. Generated when the number of
frame errors exceeds a threshold within a given window
defined by a number of frames (e.g. 10 frames out of 1000
had errors).
- Errored Frame Event. Generated when the number of frame
errors exceeds a threshold within a given window defined
by a period of time (e.g. 10 frames in 1 second had
errors).
- Errored Frame Seconds Summary Event. Generated when the
number of errored frame seconds exceeds a threshold within
a given time period (e.g. 10 errored frame seconds within
the last 100 seconds). An errored frame second is defined
as a 1 second interval which had >0 frame errors.
Context
- MIB
- WWP-OAM-MIB
- OID
.1.3.6.1.4.1.6141.2.400.1.2.6- Type
- table
- Status
- current
- Parent
- wwpOamObjs
- Siblings
- 6
- Children
- 1
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| wwpOamTable Primary controls and status for the OAM capabilities of an
Ethernet like interface. There will be one row in this table
for each Ethernet like interface in the system that suppor… | table | - | .1.3.6.1.4.1.6141.2.400.1.2.1 |
| wwpOamPeerTable Information about the OAM peer for a particular Ethernet like
interface. OAM entities communicate with a single OAM peer
entity on full-duplex Ethernet links on which OAM is enabl… | table | - | .1.3.6.1.4.1.6141.2.400.1.2.2 |
| wwpOamLoopbackTable This table contains methods to control the loopback state of
the local link as well as indicating the status of the
loopback function.
Loopback can be used to place t… | table | - | .1.3.6.1.4.1.6141.2.400.1.2.3 |
| wwpOamStatsTable Statistics for the OAM function on a particular Ethernet like
interface. | table | - | .1.3.6.1.4.1.6141.2.400.1.2.4 |
| wwpOamSystemEnableDisable Global Enable/disable OAM on the switch | scalar | Enumeration | .1.3.6.1.4.1.6141.2.400.1.2.5 |
| wwpOamEventLogTable This table records a history of the events that have occurred
at the Ethernet OAM level. These events can include locally
detected events, which may result in locally generated
O… | table | - | .1.3.6.1.4.1.6141.2.400.1.2.7 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| wwpOamEventConfigEntry Event configuration information is available for every
Ethernet like interface that supports OAM and the event
function of OAM as indicated in the wwpOamFunctionsSupported
attribu… | row | - | .1.3.6.1.4.1.6141.2.400.1.2.6.1 |