wwpOamCriticalEventEnable

WWP-OAM-MIB · .1.3.6.1.4.1.6141.2.400.1.2.6.1.12

Object

column r/w Enumeration
Indicates whether the local device should attempt to indicate
a critical event fault via the OAMPDU flags field to its peer
OAM entity.  If the system does not support critical event
capability, setting this object has no effect, and reading the
object should always result in 'disabled(2)'.  
                              
By default, this object should have the value disabled(2) for
Ethernet like interfaces that support OAM.  If the OAM layer
does not support event notifications (as indicated via the
wwpOamFunctionsSupported attribute), this value is ignored.

Context

MIB
WWP-OAM-MIB
OID
.1.3.6.1.4.1.6141.2.400.1.2.6.1.12
Type
column
Access
readwrite
Status
current
Parent
wwpOamEventConfigEntry
Table
wwpOamEventConfigTable
Siblings
11

Syntax

Enumeration

Values & Constraints

Enumerated Values
1enabled
2disabled

Related Objects

Sibling Objects