mltVdcDiff

VES1724-58V-MIB · .1.3.6.1.4.1.890.1.5.12.49.18.1.5.1.6

Object

column 0.1 voltSNMPv2-SMIInteger32
DC voltage between TIP and RING.
[Special value]:
250000016 : No result.
250000032 : Test failed.
250000048 : 'Not Measured' reason # 1: Can't start the test when port is enabled and force not set.
250000064 : 'Not Measured' reason # 2: Can't start the test when port is off-hook.
250000080 : 'Not Measured' reason # 3: Can't start the test when port is disabled or on-hook.
250000096 : 'Not Measured' reason # 4: can't start the test when port is disabled or off-hook or service state is out-of-service.
250000112 : 'Not Measured' reason # 5: can't start the test when port is disabled or off-hook.
250000128 : 'Not Measured' reason # 6: The test item will be skipped when testing all items and (vTip > 0.5Vac or vRing > 0.5Vac or abs(vTip) > 0.5Vdc or abs(vRing) > 0.5Vdc).
250000144 : 'Not Measured' reason # 7: Hardware driver do not measure this item.

Context

MIB
VES1724-58V-MIB
OID
.1.3.6.1.4.1.890.1.5.12.49.18.1.5.1.6
Type
column
Access
readonly
Status
current
Units
0.1 volt
Parent
mltResultEntry

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'VES1724-58V-MIB' -M '/opt/observium/mibs/zyxel:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'VES1724-58V-MIB::mltVdcDiff'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'VES1724-58V-MIB' -M '/opt/observium/mibs/zyxel:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'VES1724-58V-MIB::mltVdcDiff.<ifIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'VES1724-58V-MIB' -M '/opt/observium/mibs/zyxel:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'VES1724-58V-MIB::mltVdcDiff'

Syntax

Source
SNMPv2-SMIInteger32
Base type
Integer32

Values & Constraints

Type Constraints
range: -2147483648..2147483647