xdsl2LConfProfRaUsTimeUs
VDSL2-LINE-MIB ·
.1.3.6.1.2.1.10.251.1.5.1.2.1.11
Object
column
r/w
seconds Unsigned32
The Upstream Up-Shift Time Interval, to be used when xdsl2LConfProfRaModeUs is set to 'dynamicRa'. The interval of time the upstream noise margin should stay above the Upstream Up-Shift Noise Margin before the xTU-C shall attempt to increase the upstream net data rate. The time interval ranges from 0 to 16383 seconds.
Context
- MIB
- VDSL2-LINE-MIB
- OID
.1.3.6.1.2.1.10.251.1.5.1.2.1.11- Type
- column
- Access
- readwrite
- Status
- current
- Units
- seconds
- Parent
- xdsl2LineConfProfEntry
Syntax
seconds Unsigned32
Values & Constraints
Object Constraints
range: 0-16383