xdsl2LConfProfL2Atpr

VDSL2-LINE-MIB · .1.3.6.1.2.1.10.251.1.5.1.2.1.33

Object

column r/w dB Unsigned32
The maximum aggregate transmit power reduction (in dB) that
can be performed at transition of L0 to L2 state or through a
single Power Trim in the L2 state.
It ranges from 0 dB to 31 dB.

Context

MIB
VDSL2-LINE-MIB
OID
.1.3.6.1.2.1.10.251.1.5.1.2.1.33
Type
column
Access
readwrite
Status
current
Units
dB
Parent
xdsl2LineConfProfEntry
Table
xdsl2LineConfProfTable
Siblings
47

Syntax

dB Unsigned32

Values & Constraints

Object Constraints
range: 0-31