xdsl2LConfProfDpboEsEL

VDSL2-LINE-MIB · .1.3.6.1.2.1.10.251.1.5.1.2.1.37

Object

column r/w 0.5 dB Unsigned32
This configuration parameter defines the assumed electrical
length of cables (E-side cables) connecting exchange-based DSL
services to a remote flexibility point (cabinet), that hosts the
xTU-C that is subject to spectrally shaped downstream power back-
off (DPBO) depending on this length.  The electrical length is
defined as the loss (in dB) of an equivalent length of
hypothetical cable at a reference frequency defined by the
network operator or in spectrum management regulations.
This parameter shall be coded as an unsigned integer representing
an electrical length from 0 dB (coded as 0) to 255.5 dB (coded as
511) in steps of 0.5 dB.  All values in the range are valid.  If
this parameter is set to '0', the DPBO shall be disabled.

Context

MIB
VDSL2-LINE-MIB
OID
.1.3.6.1.2.1.10.251.1.5.1.2.1.37
Type
column
Access
readwrite
Status
current
Units
0.5 dB
Parent
xdsl2LineConfProfEntry
Table
xdsl2LineConfProfTable
Siblings
47

Syntax

0.5 dB Unsigned32

Values & Constraints

Object Constraints
range: 0-511

Related Objects

Sibling Objects