vdslPerfUASsThreshNotification
VDSL-LINE-MIB ·
.1.3.6.1.2.1.10.97.1.0.7
Object
notification
Unavailable Seconds 15-minute interval threshold (vdslLineAlarmConfThresh15MinUASs) reached.
Context
- MIB
- VDSL-LINE-MIB
- OID
.1.3.6.1.2.1.10.97.1.0.7- Type
- notification
- Status
- current
- Parent
- vdslNotifications
- Siblings
- 11
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| vdslPerfLofsThreshNotification Loss of Framing 15-minute interval threshold
(vdslLineAlarmConfThresh15MinLofs) reached. | notification | - | .1.3.6.1.2.1.10.97.1.0.1 |
| vdslUpMaxSnrMgnNotification The upstream Signal to Noise Margin exceeded
vdslLineConfUpMaxSnrMgn. The object vdslPhysCurrSnrMgn
will contain the Signal to Noise margin as measured
by the VTU-C. | notification | - | .1.3.6.1.2.1.10.97.1.0.10 |
| vdslUpMinSnrMgnNotification The upstream Signal to Noise Margin fell below
vdslLineConfUpMinSnrMgn. The object vdslPhysCurrSnrMgn
will contain the Signal to Noise margin as measured
by the VTU-C. | notification | - | .1.3.6.1.2.1.10.97.1.0.11 |
| vdslInitFailureNotification Vtu initialization failed. See vdslPhysCurrStatus for
potential reasons. | notification | - | .1.3.6.1.2.1.10.97.1.0.12 |
| vdslPerfLossThreshNotification Loss of Signal 15-minute interval threshold
(vdslLineAlarmConfThresh15MinLoss) reached. | notification | - | .1.3.6.1.2.1.10.97.1.0.2 |
| vdslPerfLprsThreshNotification Loss of Power 15-minute interval threshold
(vdslLineAlarmConfThresh15MinLprs) reached. | notification | - | .1.3.6.1.2.1.10.97.1.0.3 |
| vdslPerfLolsThreshNotification Loss of Link 15-minute interval threshold
(vdslLineAlarmConfThresh15MinLols) reached. | notification | - | .1.3.6.1.2.1.10.97.1.0.4 |
| vdslPerfESsThreshNotification Errored Seconds 15-minute interval threshold
(vdslLineAlarmConfThresh15MinESs) reached. | notification | - | .1.3.6.1.2.1.10.97.1.0.5 |
| vdslPerfSESsThreshNotification Severely Errored Seconds 15-minute interval threshold
(vdslLineAlarmConfThresh15MinSESs) reached. | notification | - | .1.3.6.1.2.1.10.97.1.0.6 |
| vdslDownMaxSnrMgnNotification The downstream Signal to Noise Margin exceeded
vdslLineConfDownMaxSnrMgn. The object
vdslPhysCurrSnrMgn will contain the Signal to Noise
margin as measured by the VTU-R. | notification | - | .1.3.6.1.2.1.10.97.1.0.8 |
| vdslDownMinSnrMgnNotification The downstream Signal to Noise Margin fell below
vdslLineConfDownMinSnrMgn. The object vdslPhysCurrSnrMgn
will contain the Signal to Noise margin as measured by
the VTU-R. | notification | - | .1.3.6.1.2.1.10.97.1.0.9 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| vdslPerfDataCurr15MinUASs Count of Unavailable Seconds during this interval. | column | seconds HC-PerfHist-TC-MIBHCPerfCurrentCount | .1.3.6.1.2.1.10.97.1.1.4.1.18 |