VDSL-LINE-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
11
Rows
11
Columns
143
.1.3.6.1.2.1.10.97.1.1.1 · 1 row entry · 4 columns
Uses the rfc variant from /opt/observium/mibs/rfc.
Command help
Walk vdslLineTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'VDSL-LINE-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'VDSL-LINE-MIB::vdslLineTable'
This table includes common attributes describing
both ends of the line.  It is required for all VDSL
physical interfaces.  VDSL physical interfaces are
those ifEntries where ifType is equal to vdsl(97).
vdslLineEntry row .1.3.6.1.2.1.10.97.1.1.1.1
An entry in the vdslLineTable.
Indexes
Column Syntax OID
vdslLineCodingSpecifies the VDSL coding type used on this line.VdslLineCodingType
Type Values:
1other
2mcm
3scm
.1.3.6.1.2.1.10.97.1.1.1.1.1
vdslLineTypeDefines the type of VDSL physical line entity that exists,
by defining whether and how the line is channelized. If

the line is channelized, the value will be other than
noChannel(1). This object define…
Enumeration
Enumerated Values:
1noChannel
2fastOnly
3interleavedOnly
4fastOrInterleaved
5fastAndInterleaved
.1.3.6.1.2.1.10.97.1.1.1.1.2
vdslLineConfProfileThe value of this object identifies the row in the VDSL
Line Configuration Profile Table, vdslLineConfProfileTable,
which applies for this VDSL line, and channels if
applicable.

This object MUST be mainta…
OctetStringr/w
Constraints:
range: 1-32
.1.3.6.1.2.1.10.97.1.1.1.1.3
vdslLineAlarmConfProfileThe value of this object identifies the row in the VDSL
Line Alarm Configuration Profile Table,
vdslLineAlarmConfProfileTable, which applies to this
VDSL line, and channels if applicable.

This object MUST…
OctetStringr/w
Constraints:
range: 1-32
.1.3.6.1.2.1.10.97.1.1.1.1.4
.1.3.6.1.2.1.10.97.1.1.2 · 1 row entry · 10 columns
Uses the rfc variant from /opt/observium/mibs/rfc.
Command help
Walk vdslPhysTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'VDSL-LINE-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'VDSL-LINE-MIB::vdslPhysTable'
This table provides one row for each Vtu.  Each row
contains the Physical Layer Parameters table for that
Vtu.  VDSL physical interfaces are those ifEntries where
ifType is equal to vdsl(97).
vdslPhysEntry row .1.3.6.1.2.1.10.97.1.1.2.1
An entry in the vdslPhysTable.
Column Syntax OID
vdslPhysSideIdentifies whether the transceiver is the Vtuc or Vtur.VdslLineEntity
Type Values:
1vtuc
2vtur
.1.3.6.1.2.1.10.97.1.1.2.1.1
vdslPhysInvSerialNumberThe vendor specific string that identifies the

vendor equipment.
OctetString
Constraints:
range: 0-32
.1.3.6.1.2.1.10.97.1.1.2.1.2
vdslPhysInvVendorIDThe vendor ID code is a copy of the binary vendor
identification field expressed as readable characters
in hexadecimal notation.
OctetString
Constraints:
range: 0-16
.1.3.6.1.2.1.10.97.1.1.2.1.3
vdslPhysInvVersionNumberThe vendor specific version number sent by this Vtu
as part of the initialization messages. It is a copy
of the binary version number field expressed as
readable characters in hexadecimal notation.
OctetString
Constraints:
range: 0-16
.1.3.6.1.2.1.10.97.1.1.2.1.4
vdslPhysCurrSnrMgnNoise Margin as seen by this Vtu with respect to its
received signal in 0.25dB. The effective range is
-31.75 to +31.75 dB.
0.25dBmInteger32
Constraints:
range: -127-127
.1.3.6.1.2.1.10.97.1.1.2.1.5
vdslPhysCurrAtnMeasured difference in the total power transmitted by
the peer Vtu and the total power received by this Vtu.
The effective range is 0 to +63.75 dB.
0.25dBmUnsigned32
Constraints:
range: 0-255
.1.3.6.1.2.1.10.97.1.1.2.1.6
vdslPhysCurrStatusIndicates current state of the Vtu line. This is a
bit-map of possible conditions. The various bit
positions are:

0 noDefect There are no defects on the line.

1 lossOfFram…
Bits
Enumerated Values:
0noDefect
1lossOfFraming
2lossOfSignal
3lossOfPower
4lossOfSignalQuality
5lossOfLink
6dataInitFailure
7configInitFailure
8protocolInitFailure
9noPeerVtuPresent
.1.3.6.1.2.1.10.97.1.1.2.1.7
vdslPhysCurrOutputPwrMeasured total output power transmitted by this VTU.
This is the measurement that was reported during
the last activation sequence.
0.1dBmInteger32
Constraints:
range: 0-160
.1.3.6.1.2.1.10.97.1.1.2.1.8
vdslPhysCurrAttainableRateIndicates the maximum currently attainable data rate
in steps of 1000 bits/second by the Vtu. This value
will be equal to or greater than vdslPhysCurrLineRate.
Note that for SCM, the minimum and maximum data rates
are …
kbpsSNMPv2-SMIGauge32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.2.1.9
vdslPhysCurrLineRateIndicates the current data rate in steps of 1000
bits/second by the Vtu. This value will be less than
or equal to vdslPhysCurrAttainableRate. Note: 1 kbps =
1000 bps.
kbpsSNMPv2-SMIGauge32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.2.1.10
.1.3.6.1.2.1.10.97.1.1.3 · 1 row entry · 5 columns
Uses the rfc variant from /opt/observium/mibs/rfc.
Command help
Walk vdslChanTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'VDSL-LINE-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'VDSL-LINE-MIB::vdslChanTable'
This table provides one row for each Vtu channel.
VDSL channel interfaces are those ifEntries where
ifType is equal to interleave(124) or fast(125).
vdslChanEntry row .1.3.6.1.2.1.10.97.1.1.3.1
An entry in the vdslChanTable.
Column Syntax OID
vdslChanInterleaveDelayInterleave Delay for this channel.

Interleave delay applies only to the interleave
(slow) channel and defines the mapping (relative
spacing) between subsequent input bytes at the

interleave…
millisecondsSNMPv2-SMIGauge32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.3.1.1
vdslChanCrcBlockLengthIndicates the length of the channel data-block
on which the CRC operates.
bytesSNMPv2-SMIGauge32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.3.1.2
vdslChanCurrTxRateActual transmit data rate on this channel. Note: 1
kbps = 1000 bps.
kbpsSNMPv2-SMIGauge32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.3.1.3
vdslChanCurrTxSlowBurstProtectActual level of impulse noise (burst) protection
for an interleaved (slow) channel. This parameter is
not applicable to fast channels. For fast channels,
a value of zero shall be returned.
microsecondsUnsigned32
Constraints:
range: 0-1275
.1.3.6.1.2.1.10.97.1.1.3.1.4
vdslChanCurrTxFastFecActual Forward Error Correction (FEC) redundancy
related overhead for a fast channel. This parameter
is not applicable to an interleaved (slow) channel.
For interleaved channels, a value of zero shall be
returned.
%Unsigned32
Constraints:
range: 0-50
.1.3.6.1.2.1.10.97.1.1.3.1.5
.1.3.6.1.2.1.10.97.1.1.4 · 1 row entry · 30 columns
Uses the rfc variant from /opt/observium/mibs/rfc.
Command help
Walk vdslPerfDataTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'VDSL-LINE-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'VDSL-LINE-MIB::vdslPerfDataTable'
This table provides one row for each VDSL physical
interface.  VDSL physical interfaces are those ifEntries
where ifType is equal to vdsl(97).
vdslPerfDataEntry row .1.3.6.1.2.1.10.97.1.1.4.1
An entry in the vdslPerfDataTable.
Column Syntax OID
vdslPerfDataValidIntervalsValid Intervals per definition found in
HC-PerfHist-TC-MIB.
intervalsHC-PerfHist-TC-MIBHCPerfValidIntervals
Type Constraints:
range: 0..96
.1.3.6.1.2.1.10.97.1.1.4.1.1
vdslPerfDataInvalidIntervalsInvalid Intervals per definition found in
HC-PerfHist-TC-MIB.
intervalsHC-PerfHist-TC-MIBHCPerfInvalidIntervals
Type Constraints:
range: 0..96
.1.3.6.1.2.1.10.97.1.1.4.1.2
vdslPerfDataLofsCount of seconds since the unit was last reset that there
was Loss of Framing.
secondsSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.4.1.3
vdslPerfDataLossCount of seconds since the unit was last reset that there
was Loss of Signal.
secondsSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.4.1.4
vdslPerfDataLprsCount of seconds since the unit was last reset that there
was Loss of Power.
secondsSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.4.1.5
vdslPerfDataLolsCount of seconds since the unit was last reset that there
was Loss of Link.
secondsSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.4.1.6
vdslPerfDataESsCount of Errored Seconds since the unit was last reset.
An Errored Second is a one-second interval containing one
or more CRC anomalies, or one or more LOS or LOF defects.
secondsSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.4.1.7
vdslPerfDataSESsCount of Severely Errored Seconds since the unit was last
reset.
secondsSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.4.1.8
vdslPerfDataUASsCount of Unavailable Seconds since the unit was last
reset.
secondsSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.4.1.9
vdslPerfDataInitsCount of the line initialization attempts since the unit
was last reset. This count includes both successful and
failed attempts.
occurrencesSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.4.1.10
vdslPerfDataCurr15MinTimeElapsedTotal elapsed seconds in this interval.secondsHC-PerfHist-TC-MIBHCPerfTimeElapsed
Type Constraints:
range: 0..86399
.1.3.6.1.2.1.10.97.1.1.4.1.11
vdslPerfDataCurr15MinLofsCount of seconds during this interval that there
was Loss of Framing.
secondsHC-PerfHist-TC-MIBHCPerfCurrentCount.1.3.6.1.2.1.10.97.1.1.4.1.12
vdslPerfDataCurr15MinLossCount of seconds during this interval that there
was Loss of Signal.
secondsHC-PerfHist-TC-MIBHCPerfCurrentCount.1.3.6.1.2.1.10.97.1.1.4.1.13
vdslPerfDataCurr15MinLprsCount of seconds during this interval that there
was Loss of Power.
secondsHC-PerfHist-TC-MIBHCPerfCurrentCount.1.3.6.1.2.1.10.97.1.1.4.1.14
vdslPerfDataCurr15MinLolsCount of seconds during this interval that there
was Loss of Link.
secondsHC-PerfHist-TC-MIBHCPerfCurrentCount.1.3.6.1.2.1.10.97.1.1.4.1.15
vdslPerfDataCurr15MinESsCount of Errored Seconds during this interval. An Errored
Second is a one-second interval containing one or more CRC
anomalies, or one or more LOS or LOF defects.
secondsHC-PerfHist-TC-MIBHCPerfCurrentCount.1.3.6.1.2.1.10.97.1.1.4.1.16
vdslPerfDataCurr15MinSESsCount of Severely Errored Seconds during this interval.secondsHC-PerfHist-TC-MIBHCPerfCurrentCount.1.3.6.1.2.1.10.97.1.1.4.1.17
vdslPerfDataCurr15MinUASsCount of Unavailable Seconds during this interval.secondsHC-PerfHist-TC-MIBHCPerfCurrentCount.1.3.6.1.2.1.10.97.1.1.4.1.18
vdslPerfDataCurr15MinInitsCount of the line initialization attempts during this
interval. This count includes both successful and
failed attempts.
occurrencesHC-PerfHist-TC-MIBHCPerfCurrentCount.1.3.6.1.2.1.10.97.1.1.4.1.19
vdslPerfData1DayValidIntervalsValid Intervals per definition found in
HC-PerfHist-TC-MIB.
intervalsHC-PerfHist-TC-MIBHCPerfValidIntervals
Type Constraints:
range: 0..96
.1.3.6.1.2.1.10.97.1.1.4.1.20
vdslPerfData1DayInvalidIntervalsInvalid Intervals per definition found in
HC-PerfHist-TC-MIB.
intervalsHC-PerfHist-TC-MIBHCPerfInvalidIntervals
Type Constraints:
range: 0..96
.1.3.6.1.2.1.10.97.1.1.4.1.21
vdslPerfDataCurr1DayTimeElapsedNumber of seconds that have elapsed since the beginning
of the current 1-day interval.
secondsHC-PerfHist-TC-MIBHCPerfTimeElapsed
Type Constraints:
range: 0..86399
.1.3.6.1.2.1.10.97.1.1.4.1.22
vdslPerfDataCurr1DayLofsCount of Loss of Framing (LOF) Seconds since the
beginning of the current 1-day interval.
secondsSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.4.1.23
vdslPerfDataCurr1DayLossCount of Loss of Signal (LOS) Seconds since the beginning
of the current 1-day interval.
secondsSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.4.1.24
vdslPerfDataCurr1DayLprsCount of Loss of Power (LPR) Seconds since the beginning
of the current 1-day interval.
secondsSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.4.1.25
vdslPerfDataCurr1DayLolsCount of Loss of Link (LOL) Seconds since the beginning
of the current 1-day interval.
secondsSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.4.1.26
vdslPerfDataCurr1DayESsCount of Errored Seconds (ES) since the beginning
of the current 1-day interval.
secondsSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.4.1.27
vdslPerfDataCurr1DaySESsCount of Severely Errored Seconds (SES) since the
beginning of the current 1-day interval.
secondsSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.4.1.28
vdslPerfDataCurr1DayUASsCount of Unavailable Seconds (UAS) since the beginning
of the current 1-day interval.
secondsSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.4.1.29
vdslPerfDataCurr1DayInitsCount of the line initialization attempts since the
beginning of the current 1-day interval. This count
includes both successful and failed attempts.
secondsSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.4.1.30
.1.3.6.1.2.1.10.97.1.1.5 · 1 row entry · 9 columns
Uses the rfc variant from /opt/observium/mibs/rfc.
Command help
Walk vdslPerfIntervalTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'VDSL-LINE-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'VDSL-LINE-MIB::vdslPerfIntervalTable'
This table provides one row for each Vtu performance
data collection interval.  VDSL physical interfaces are
          
those ifEntries where ifType is equal to vdsl(97).
vdslPerfIntervalEntry row .1.3.6.1.2.1.10.97.1.1.5.1
An entry in the vdslPerfIntervalTable.
Column Syntax OID
vdslPerfIntervalNumberPerformance Data Interval number 1 is the most recent
previous interval; interval 96 is 24 hours ago.
Intervals 2 to 96 are optional.
Unsigned32
Constraints:
range: 1-96
.1.3.6.1.2.1.10.97.1.1.5.1.1
vdslPerfIntervalLofsCount of seconds in the interval when there was Loss
of Framing.
secondsHC-PerfHist-TC-MIBHCPerfIntervalCount.1.3.6.1.2.1.10.97.1.1.5.1.2
vdslPerfIntervalLossCount of seconds in the interval when there was Loss
of Signal.
secondsHC-PerfHist-TC-MIBHCPerfIntervalCount.1.3.6.1.2.1.10.97.1.1.5.1.3
vdslPerfIntervalLprsCount of seconds in the interval when there was Loss
of Power.
secondsHC-PerfHist-TC-MIBHCPerfIntervalCount.1.3.6.1.2.1.10.97.1.1.5.1.4
vdslPerfIntervalLolsCount of seconds in the interval when there was Loss
of Link.
secondsHC-PerfHist-TC-MIBHCPerfIntervalCount.1.3.6.1.2.1.10.97.1.1.5.1.5
vdslPerfIntervalESsCount of Errored Seconds (ES) in the interval. An Errored
Second is a one-second interval containing one or more CRC
anomalies, one or more LOS or LOF defects.
secondsHC-PerfHist-TC-MIBHCPerfIntervalCount.1.3.6.1.2.1.10.97.1.1.5.1.6
vdslPerfIntervalSESsCount of Severely Errored Seconds in the interval.secondsHC-PerfHist-TC-MIBHCPerfIntervalCount.1.3.6.1.2.1.10.97.1.1.5.1.7
vdslPerfIntervalUASsCount of Unavailable Seconds in the interval.secondsHC-PerfHist-TC-MIBHCPerfIntervalCount.1.3.6.1.2.1.10.97.1.1.5.1.8
vdslPerfIntervalInitsCount of the line initialization attempts during this
interval. This count includes both successful and
failed attempts.
HC-PerfHist-TC-MIBHCPerfIntervalCount.1.3.6.1.2.1.10.97.1.1.5.1.9
.1.3.6.1.2.1.10.97.1.1.6 · 1 row entry · 10 columns
Uses the rfc variant from /opt/observium/mibs/rfc.
Command help
Walk vdslPerf1DayIntervalTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'VDSL-LINE-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'VDSL-LINE-MIB::vdslPerf1DayIntervalTable'
This table provides one row for each VDSL performance
data collection interval.  This table contains live data
from equipment.  As such, it is NOT persistent.
vdslPerf1DayIntervalEntry row .1.3.6.1.2.1.10.97.1.1.6.1
An entry in the vdslPerf1DayIntervalTable.
Column Syntax OID
vdslPerf1DayIntervalNumberHistory Data Interval number. Interval 1 is the most
recent previous day; interval 30 is 30 days ago. Intervals
2 to 30 are optional.
Unsigned32
Constraints:
range: 1-30
.1.3.6.1.2.1.10.97.1.1.6.1.1
vdslPerf1DayIntervalMoniSecsThe amount of time in the 1-day interval over which the
performance monitoring information is actually counted.
This value will be the same as the interval duration except
in a situation where performance monitoring dat…
secondsHC-PerfHist-TC-MIBHCPerfTimeElapsed
Type Constraints:
range: 0..86399
.1.3.6.1.2.1.10.97.1.1.6.1.2
vdslPerf1DayIntervalLofsCount of Loss of Frame (LOF) Seconds during the 1-day
interval as measured by vdslPerf1DayIntervalMoniSecs.
secondsSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.6.1.3
vdslPerf1DayIntervalLossCount of Loss of Signal (LOS) Seconds during the 1-day
interval as measured by vdslPerf1DayIntervalMoniSecs.
secondsSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.6.1.4
vdslPerf1DayIntervalLprsCount of Loss of Power (LPR) Seconds during the 1-day
interval as measured by vdslPerf1DayIntervalMoniSecs.
secondsSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.6.1.5
vdslPerf1DayIntervalLolsCount of Loss of Link (LOL) Seconds during the 1-day
interval as measured by vdslPerf1DayIntervalMoniSecs.
secondsSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.6.1.6
vdslPerf1DayIntervalESsCount of Errored Seconds (ES) during the 1-day
interval as measured by vdslPerf1DayIntervalMoniSecs.
secondsSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.6.1.7
vdslPerf1DayIntervalSESsCount of Severely Errored Seconds (SES) during the 1-day
interval as measured by vdslPerf1DayIntervalMoniSecs.
secondsSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.6.1.8
vdslPerf1DayIntervalUASsCount of Unavailable Seconds (UAS) during the 1-day
interval as measured by vdslPerf1DayIntervalMoniSecs.
secondsSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.6.1.9
vdslPerf1DayIntervalInitsCount of the line initialization attempts during the
1-day interval as measured by vdslPerf1DayIntervalMoniSecs.
This count includes both successful and failed attempts.
secondsSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.6.1.10
.1.3.6.1.2.1.10.97.1.1.7 · 1 row entry · 12 columns
Uses the rfc variant from /opt/observium/mibs/rfc.
Command help
Walk vdslChanPerfDataTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'VDSL-LINE-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'VDSL-LINE-MIB::vdslChanPerfDataTable'
This table provides one row for each Vtu channel.
VDSL channel interfaces are those ifEntries where
ifType is equal to interleave(124) or fast(125).
vdslChanPerfDataEntry row .1.3.6.1.2.1.10.97.1.1.7.1
An entry in the vdslChanPerfDataTable.
Column Syntax OID
vdslChanValidIntervalsValid Intervals per definition found in
HC-PerfHist-TC-MIB.
intervalsHC-PerfHist-TC-MIBHCPerfValidIntervals
Type Constraints:
range: 0..96
.1.3.6.1.2.1.10.97.1.1.7.1.1
vdslChanInvalidIntervalsInvalid Intervals per definition found in
HC-PerfHist-TC-MIB.
intervalsHC-PerfHist-TC-MIBHCPerfInvalidIntervals
Type Constraints:
range: 0..96
.1.3.6.1.2.1.10.97.1.1.7.1.2
vdslChanFixedOctetsCount of corrected octets since the unit was last reset.octetsHCNUM-TCZeroBasedCounter64.1.3.6.1.2.1.10.97.1.1.7.1.3
vdslChanBadBlksCount of uncorrectable blocks since the unit was last
reset.
blocksHCNUM-TCZeroBasedCounter64.1.3.6.1.2.1.10.97.1.1.7.1.4
vdslChanCurr15MinTimeElapsedTotal elapsed seconds in this interval.secondsHC-PerfHist-TC-MIBHCPerfTimeElapsed
Type Constraints:
range: 0..86399
.1.3.6.1.2.1.10.97.1.1.7.1.5
vdslChanCurr15MinFixedOctetsCount of corrected octets in this interval.octetsHC-PerfHist-TC-MIBHCPerfCurrentCount.1.3.6.1.2.1.10.97.1.1.7.1.6
vdslChanCurr15MinBadBlksCount of uncorrectable blocks in this interval.blocksHC-PerfHist-TC-MIBHCPerfCurrentCount.1.3.6.1.2.1.10.97.1.1.7.1.7
vdslChan1DayValidIntervalsValid Intervals per definition found in
HC-PerfHist-TC-MIB.
HC-PerfHist-TC-MIBHCPerfValidIntervals
Type Constraints:
range: 0..96
.1.3.6.1.2.1.10.97.1.1.7.1.8
vdslChan1DayInvalidIntervalsInvalid Intervals per definition found in
HC-PerfHist-TC-MIB.
HC-PerfHist-TC-MIBHCPerfInvalidIntervals
Type Constraints:
range: 0..96
.1.3.6.1.2.1.10.97.1.1.7.1.9
vdslChanCurr1DayTimeElapsedNumber of seconds that have elapsed since the beginning
of the current 1-day interval.
secondsHC-PerfHist-TC-MIBHCPerfTimeElapsed
Type Constraints:
range: 0..86399
.1.3.6.1.2.1.10.97.1.1.7.1.10
vdslChanCurr1DayFixedOctetsCount of corrected octets since the beginning of the
current 1-day interval.
octetsHC-PerfHist-TC-MIBHCPerfCurrentCount.1.3.6.1.2.1.10.97.1.1.7.1.11
vdslChanCurr1DayBadBlksCount of uncorrectable blocks since the beginning of the
current 1-day interval.
blocksHC-PerfHist-TC-MIBHCPerfCurrentCount.1.3.6.1.2.1.10.97.1.1.7.1.12
.1.3.6.1.2.1.10.97.1.1.8 · 1 row entry · 3 columns
Uses the rfc variant from /opt/observium/mibs/rfc.
Command help
Walk vdslChanIntervalTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'VDSL-LINE-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'VDSL-LINE-MIB::vdslChanIntervalTable'
This table provides one row for each Vtu channel data
collection interval.  VDSL channel interfaces are those
ifEntries where ifType is equal to interleave(124) or
fast(125).
vdslChanIntervalEntry row .1.3.6.1.2.1.10.97.1.1.8.1
An entry in the vdslChanIntervalTable.
Column Syntax OID
vdslChanIntervalNumberPerformance Data Interval number 1 is the most recent
previous interval; interval 96 is 24 hours ago.
Intervals 2 to 96 are optional.
Unsigned32
Constraints:
range: 1-96
.1.3.6.1.2.1.10.97.1.1.8.1.1
vdslChanIntervalFixedOctetsCount of corrected octets in this interval.octetsHC-PerfHist-TC-MIBHCPerfIntervalCount.1.3.6.1.2.1.10.97.1.1.8.1.2
vdslChanIntervalBadBlksCount of uncorrectable blocks in this interval.blocksHC-PerfHist-TC-MIBHCPerfIntervalCount.1.3.6.1.2.1.10.97.1.1.8.1.3
.1.3.6.1.2.1.10.97.1.1.9 · 1 row entry · 4 columns
Uses the rfc variant from /opt/observium/mibs/rfc.
Command help
Walk vdslChan1DayIntervalTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'VDSL-LINE-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'VDSL-LINE-MIB::vdslChan1DayIntervalTable'
This table provides one row for each VDSL performance
data collection interval.  This table contains live data
from equipment.  As such, it is NOT persistent.
vdslChan1DayIntervalEntry row .1.3.6.1.2.1.10.97.1.1.9.1
An entry in the vdslChan1DayIntervalTable.
Column Syntax OID
vdslChan1DayIntervalNumberHistory Data Interval number. Interval 1 is the most
recent previous day; interval 30 is 30 days ago. Intervals
2 to 30 are optional.
Unsigned32
Constraints:
range: 1-30
.1.3.6.1.2.1.10.97.1.1.9.1.1
vdslChan1DayIntervalMoniSecsThe amount of time in the 1-day interval over which the
performance monitoring information is actually counted.
This value will be the same as the interval duration except
in a situation where performance monitoring dat…
secondsHC-PerfHist-TC-MIBHCPerfTimeElapsed
Type Constraints:
range: 0..86399
.1.3.6.1.2.1.10.97.1.1.9.1.2
vdslChan1DayIntervalFixedOctetsCount of corrected octets in this interval.octetsHC-PerfHist-TC-MIBHCPerfCurrentCount.1.3.6.1.2.1.10.97.1.1.9.1.3
vdslChan1DayIntervalBadBlksCount of uncorrectable blocks in this interval.blocksHC-PerfHist-TC-MIBHCPerfCurrentCount.1.3.6.1.2.1.10.97.1.1.9.1.4
.1.3.6.1.2.1.10.97.1.1.11 · 1 row entry · 46 columns
Uses the rfc variant from /opt/observium/mibs/rfc.
Command help
Walk vdslLineConfProfileTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'VDSL-LINE-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'VDSL-LINE-MIB::vdslLineConfProfileTable'
This table contains information on the VDSL line
configuration.  One entry in this table reflects a
profile defined by a manager which can be used to
configure the VDSL line.
          
Entries in this table MUST be maintained in a
persistent manner.
vdslLineConfProfileEntry row .1.3.6.1.2.1.10.97.1.1.11.1
Each entry consists of a list of parameters that
represents the configuration of a VDSL line.

A default profile with an index of 'DEFVAL', will
always exist and its parameters will be set to vendor
specific…
Column Syntax OID
vdslLineConfProfileNameThis object identifies a row in this table.

A default profile with an index of 'DEFVAL', will
always exist and its parameters will be set to vendor
specific values, unless otherwise specified in this
docu…
OctetString
Constraints:
range: 1-32
.1.3.6.1.2.1.10.97.1.1.11.1.1
vdslLineConfDownRateModeSpecifies the rate selection behavior for the line
in the downstream direction.

manual(1) forces the rate to the configured rate
adaptAtInit(2) adapts the line based upon line quality.
Enumerationr/w
Enumerated Values:
1manual
2adaptAtInit
.1.3.6.1.2.1.10.97.1.1.11.1.2
vdslLineConfUpRateModeSpecifies the rate selection behavior for the line
in the upstream direction.

manual(1) forces the rate to the configured rate
adaptAtInit(2) adapts the line based upon line quality.
Enumerationr/w
Enumerated Values:
1manual
2adaptAtInit
.1.3.6.1.2.1.10.97.1.1.11.1.3
vdslLineConfDownMaxPwrSpecifies the maximum aggregate downstream power
level in the range 0 to 14.5 dBm.
0.25dBmUnsigned32r/w
Constraints:
range: 0-58
.1.3.6.1.2.1.10.97.1.1.11.1.4
vdslLineConfUpMaxPwrSpecifies the maximum aggregate upstream power
level in the range 0 to 14.5 dBm.
0.25dBmUnsigned32r/w
Constraints:
range: 0-58
.1.3.6.1.2.1.10.97.1.1.11.1.5
vdslLineConfDownMaxSnrMgnSpecifies the maximum downstream Signal/Noise Margin
in units of 0.25 dB, for a range of 0 to 31.75 dB.
0.25dBmUnsigned32r/w
Constraints:
range: 0-127
.1.3.6.1.2.1.10.97.1.1.11.1.6
vdslLineConfDownMinSnrMgnSpecifies the minimum downstream Signal/Noise Margin
in units of 0.25 dB, for a range of 0 to 31.75 dB.
0.25dBmUnsigned32r/w
Constraints:
range: 0-127
.1.3.6.1.2.1.10.97.1.1.11.1.7
vdslLineConfDownTargetSnrMgnSpecifies the target downstream Signal/Noise Margin
in units of 0.25 dB, for a range of 0 to 31.75 dB.
This is the Noise Margin the transceivers must achieve
with a BER of 10^-7 or better to successfully complete
initia…
0.25dBmUnsigned32r/w
Constraints:
range: 0-127
.1.3.6.1.2.1.10.97.1.1.11.1.8
vdslLineConfUpMaxSnrMgnSpecifies the maximum upstream Signal/Noise Margin
in units of 0.25 dB, for a range of 0 to 31.75 dB.
0.25dBmUnsigned32r/w
Constraints:
range: 0-127
.1.3.6.1.2.1.10.97.1.1.11.1.9
vdslLineConfUpMinSnrMgnSpecifies the minimum upstream Signal/Noise Margin
in units of 0.25 dB, for a range of 0 to 31.75 dB.
0.25dBmUnsigned32r/w
Constraints:
range: 0-127
.1.3.6.1.2.1.10.97.1.1.11.1.10
vdslLineConfUpTargetSnrMgnSpecifies the target upstream Signal/Noise Margin in
units of 0.25 dB, for a range of 0 to 31.75 dB. This
is the Noise Margin the transceivers must achieve with
a BER of 10^-7 or better to successfully complete
initial…
0.25dBmUnsigned32r/w
Constraints:
range: 0-127
.1.3.6.1.2.1.10.97.1.1.11.1.11
vdslLineConfDownFastMaxDataRateSpecifies the maximum downstream fast channel
data rate in steps of 1000 bits/second.
kbpsSNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.11.1.12
vdslLineConfDownFastMinDataRateSpecifies the minimum downstream fast channel
data rate in steps of 1000 bits/second.
kbpsSNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.11.1.13
vdslLineConfDownSlowMaxDataRateSpecifies the maximum downstream slow channel
data rate in steps of 1000 bits/second.

The maximum aggregate downstream transmit speed
of the line can be derived from the sum of maximum
downstream fast and…
kbpsSNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.11.1.14
vdslLineConfDownSlowMinDataRateSpecifies the minimum downstream slow channel
data rate in steps of 1000 bits/second.

The minimum aggregate downstream transmit speed
of the line can be derived from the sum of minimum
downstream fast and…
kbpsSNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.11.1.15
vdslLineConfUpFastMaxDataRateSpecifies the maximum upstream fast channel
data rate in steps of 1000 bits/second.

The maximum aggregate upstream transmit speed
of the line can be derived from the sum of maximum
upstream fast and slow …
kbpsSNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.11.1.16
vdslLineConfUpFastMinDataRateSpecifies the minimum upstream fast channel
data rate in steps of 1000 bits/second.

The minimum aggregate upstream transmit speed
of the line can be derived from the sum of minimum
upstream fast and slow …
kbpsSNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.11.1.17
vdslLineConfUpSlowMaxDataRateSpecifies the maximum upstream slow channel
data rate in steps of 1000 bits/second.
kbpsSNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.11.1.18
vdslLineConfUpSlowMinDataRateSpecifies the minimum upstream slow channel
data rate in steps of 1000 bits/second.
kbpsSNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.11.1.19
vdslLineConfDownRateRatioFor dynamic rate adaptation at startup, the allocation
of data rate in excess of the minimum data rate for each
channel is controlled by the object. This object specifies
the ratio of the allocation of the excess data …
percentUnsigned32r/w
Constraints:
range: 0-100
.1.3.6.1.2.1.10.97.1.1.11.1.20
vdslLineConfUpRateRatioFor dynamic rate adaptation at startup, the allocation
of data rate in excess of the minimum data rate for each
channel is controlled by the object. This object specifies
the ratio of the allocation of the excess data …
percentUnsigned32r/w
Constraints:
range: 0-100
.1.3.6.1.2.1.10.97.1.1.11.1.21
vdslLineConfDownMaxInterDelaySpecifies the maximum interleave delay for the
downstream slow channel.
millisecondsUnsigned32r/w
Constraints:
range: 0-255
.1.3.6.1.2.1.10.97.1.1.11.1.22
vdslLineConfUpMaxInterDelaySpecifies the maximum interleave delay for the
upstream slow channel.
millisecondsUnsigned32r/w
Constraints:
range: 0-255
.1.3.6.1.2.1.10.97.1.1.11.1.23
vdslLineConfDownPboControlDownstream power backoff (PBO) control for this
line. For transceivers which do not support downstream
PBO control, this object MUST be fixed at disabled(1).
If auto(2) is selected, the transceiver will automatically
a…
Enumerationr/w
Enumerated Values:
1disabled
2auto
3manual
.1.3.6.1.2.1.10.97.1.1.11.1.24
vdslLineConfUpPboControlUpstream power backoff (PBO) control for this
line. For transceivers which do not support upstream
PBO control, this object MUST be fixed at disabled(1).
If auto(2) is selected, the transceiver will automatically
adjus…
Enumerationr/w
Enumerated Values:
1disabled
2auto
3manual
.1.3.6.1.2.1.10.97.1.1.11.1.25
vdslLineConfDownPboLevelSpecifies the downstream backoff level to be used
when vdslLineConfDownPboControl = manual(3).
0.25dBUnsigned32r/w
Constraints:
range: 0-160
.1.3.6.1.2.1.10.97.1.1.11.1.26
vdslLineConfUpPboLevelSpecifies the upstream backoff level to be used
when vdslLineConfUpPboControl = manual(3).
0.25dBUnsigned32r/w
Constraints:
range: 0-160
.1.3.6.1.2.1.10.97.1.1.11.1.27
vdslLineConfDeploymentScenarioThe VDSL line deployment scenario. When using
fttCab(1), the VTU-C is located in a street cabinet.
When using fttEx(2), the VTU-C is located at the
central office. Changes to this value will have
no effect on the tran…
Enumerationr/w
Enumerated Values:
1fttCab
2fttEx
3other
.1.3.6.1.2.1.10.97.1.1.11.1.28
vdslLineConfAdslPresenceIndicates presence of ADSL service in the associated
cable bundle/binder.

none(1) indicates no ADSL service in the bundle
adslOverPots(2) indicates ADSL service over POTS is
presen…
Enumerationr/w
Enumerated Values:
1none
2adslOverPots
3adslOverISDN
.1.3.6.1.2.1.10.97.1.1.11.1.29
vdslLineConfApplicableStandardThe VDSL standard to be used for the line.

ansi(1) indicates ANSI standard
etsi(2) indicates ETSI standard
itu(3) indicates ITU standard
other(4) indicates a standard other than the ab…
Enumerationr/w
Enumerated Values:
1ansi
2etsi
3itu
4other
.1.3.6.1.2.1.10.97.1.1.11.1.30
vdslLineConfBandPlanThe VDSL band plan to be used for the line.

bandPlan997(1) is to be used for
ITU-T G.993.1 Bandplan-B
ETSI Bandplan
ANSI Plan 997

bandPlan998(2) is to be used for
ITU-T …
Enumerationr/w
Enumerated Values:
1bandPlan997
2bandPlan998
3bandPlanFx
4other
.1.3.6.1.2.1.10.97.1.1.11.1.31
vdslLineConfBandPlanFxThe frequency limit between bands D2 and U2 when
vdslLineConfBandPlan is set to bandPlanFx(3).
kHzUnsigned32r/w
Constraints:
range: 3750-12000
.1.3.6.1.2.1.10.97.1.1.11.1.32
vdslLineConfBandOptUsageDefines the VDSL link use of the optional frequency
range [25kHz - 138kHz] (Opt).

unused(1) indicates Opt is unused
upstream(2) indicates Opt usage is for upstream
downstream(3) indicates Opt usage …
Enumerationr/w
Enumerated Values:
1unused
2upstream
3downstream
.1.3.6.1.2.1.10.97.1.1.11.1.33
vdslLineConfUpPsdTemplateThe upstream PSD template to be used for the line.
Here, templateMask1(1) refers to a notched mask that
limits the transmitted PSD within the internationally
standardized HAM (Handheld Amateur Radio) radio bands,
while …
Enumerationr/w
Enumerated Values:
1templateMask1
2templateMask2
.1.3.6.1.2.1.10.97.1.1.11.1.34
vdslLineConfDownPsdTemplateThe downstream PSD template to be used for the line.
Here, templateMask1(1) refers to a notched mask that
limits the transmitted PSD within the internationally
standardized HAM (Handheld Amateur Radio) radio bands,
whil…
Enumerationr/w
Enumerated Values:
1templateMask1
2templateMask2
.1.3.6.1.2.1.10.97.1.1.11.1.35
vdslLineConfHamBandMaskThe transmit power spectral density mask code, used
to avoid interference with HAM (Handheld Amateur Radio)
radio bands by introducing power control (notching) in one
or more of these bands.

Amateur radio…
Bitsr/w
Enumerated Values:
0customNotch1
1customNotch2
2amateurBand30m
3amateurBand40m
4amateurBand80m
5amateurBand160m
.1.3.6.1.2.1.10.97.1.1.11.1.36
vdslLineConfCustomNotch1StartSpecifies the start frequency of custom HAM (Handheld
Amateur Radio) notch 1. vdslLineConfCustomNotch1Start MUST
be less than or equal to vdslLineConfCustomNotch1Stop.
kHzSNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.11.1.37
vdslLineConfCustomNotch1StopSpecifies the stop frequency of custom HAM (Handheld
Amateur Radio) notch 1. vdslLineConfCustomNotch1Stop MUST
be greater than or equal to vdslLineConfCustomNotch1Start.
kHzSNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.11.1.38
vdslLineConfCustomNotch2StartSpecifies the start frequency of custom HAM (Handheld
Amateur Radio) notch 2. vdslLineConfCustomNotch2Start MUST
be less than or equal to vdslLineConfCustomNotch2Stop.
kHzSNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.11.1.39
vdslLineConfCustomNotch2StopSpecifies the stop frequency of custom HAM (Handheld
Amateur Radio) notch 2. vdslLineConfCustomNotch2Stop MUST
be greater than or equal to vdslLineConfCustomNotch2Start.
kHzSNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.2.1.10.97.1.1.11.1.40
vdslLineConfDownTargetSlowBurstSpecifies the target level of impulse noise (burst)
protection for an interleaved (slow) channel.
microsecondsUnsigned32r/w
Constraints:
range: 0-1275
.1.3.6.1.2.1.10.97.1.1.11.1.41
vdslLineConfUpTargetSlowBurstSpecifies the target level of impulse noise (burst)
protection for an interleaved (slow) channel.
microsecondsUnsigned32r/w
Constraints:
range: 0-1275
.1.3.6.1.2.1.10.97.1.1.11.1.42
vdslLineConfDownMaxFastFecThis parameter provisions the maximum level of Forward
Error Correction (FEC) redundancy related overhead to
be maintained for a fast channel.
%Unsigned32r/w
Constraints:
range: 0-50
.1.3.6.1.2.1.10.97.1.1.11.1.43
vdslLineConfUpMaxFastFecThis parameter provisions the maximum level of Forward
Error Correction (FEC) redundancy related overhead to
be maintained for a fast channel.
%Unsigned32r/w
Constraints:
range: 0-50
.1.3.6.1.2.1.10.97.1.1.11.1.44
vdslLineConfLineTypeThis parameter provisions the VDSL physical entity at
start-up by defining whether and how the line will be
channelized, i.e., which channel type(s) are supported.
If the line is to be channelized, the value will be oth…
Enumerationr/w
Enumerated Values:
1noChannel
2fastOnly
3interleavedOnly
4fastOrInterleaved
5fastAndInterleaved
.1.3.6.1.2.1.10.97.1.1.11.1.45
vdslLineConfProfRowStatusThis object is used to create a new row or modify or
delete an existing row in this table.

A profile activated by setting this object to 'active'.
When 'active' is set, the system will validate the profil…
SNMPv2-TCRowStatusr/w
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.2.1.10.97.1.1.11.1.46
.1.3.6.1.2.1.10.97.1.1.20 · 1 row entry · 10 columns
Uses the rfc variant from /opt/observium/mibs/rfc.
Command help
Walk vdslLineAlarmConfProfileTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'VDSL-LINE-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'VDSL-LINE-MIB::vdslLineAlarmConfProfileTable'
This table contains information on the VDSL line alarm
configuration.  One entry in this table reflects a profile
defined by a manager which can be used to configure the
VDSL line alarm thresholds.
          
Entries in this table MUST be maintained in a
persistent manner.
vdslLineAlarmConfProfileEntry row .1.3.6.1.2.1.10.97.1.1.20.1
Each entry consists of a list of parameters that
represents the configuration of a VDSL line alarm
profile.

A default profile with an index of 'DEFVAL', will
always exist and its parameters will be set to v…
Column Syntax OID
vdslLineAlarmConfProfileNameThe name for this profile as specified by an
administrator.
OctetString
Constraints:
range: 1-32
.1.3.6.1.2.1.10.97.1.1.20.1.1
vdslLineAlarmConfThresh15MinLofsThis object configures the threshold for the number of
loss of frame seconds (lofs) within any given 15-minute
performance data collection interval. If the value of
loss of frame seconds in a particular 15-minute colle…
secondsHC-PerfHist-TC-MIBHCPerfIntervalThresholdr/w
Type Constraints:
range: 0..900
.1.3.6.1.2.1.10.97.1.1.20.1.2
vdslLineAlarmConfThresh15MinLossThis object configures the threshold for the number of
loss of signal seconds (loss) within any given 15-minute
performance data collection interval. If the value of
loss of signal seconds in a particular 15-minute
col…
secondsHC-PerfHist-TC-MIBHCPerfIntervalThresholdr/w
Type Constraints:
range: 0..900
.1.3.6.1.2.1.10.97.1.1.20.1.3
vdslLineAlarmConfThresh15MinLprsThis object configures the threshold for the number of
loss of power seconds (lprs) within any given 15-minute
performance data collection interval. If the value of
loss of power seconds in a particular 15-minute colle…
secondsHC-PerfHist-TC-MIBHCPerfIntervalThresholdr/w
Type Constraints:
range: 0..900
.1.3.6.1.2.1.10.97.1.1.20.1.4
vdslLineAlarmConfThresh15MinLolsThis object configures the threshold for the number of
loss of link seconds (lols) within any given 15-minute
performance data collection interval. If the value of
loss of power seconds in a particular 15-minute collec…
secondsHC-PerfHist-TC-MIBHCPerfIntervalThresholdr/w
Type Constraints:
range: 0..900
.1.3.6.1.2.1.10.97.1.1.20.1.5
vdslLineAlarmConfThresh15MinESsThis object configures the threshold for the number of
errored seconds (ESs) within any given 15-minute
performance data collection interval. If the value of
errored seconds in a particular 15-minute collection
interva…
secondsHC-PerfHist-TC-MIBHCPerfIntervalThresholdr/w
Type Constraints:
range: 0..900
.1.3.6.1.2.1.10.97.1.1.20.1.6
vdslLineAlarmConfThresh15MinSESsThis object configures the threshold for the number of
severely errored seconds (SESs) within any given 15-minute
performance data collection interval. If the value of
severely errored seconds in a particular 15-minute…
secondsHC-PerfHist-TC-MIBHCPerfIntervalThresholdr/w
Type Constraints:
range: 0..900
.1.3.6.1.2.1.10.97.1.1.20.1.7
vdslLineAlarmConfThresh15MinUASsThis object configures the threshold for the number of
unavailable seconds (UASs) within any given 15-minute
performance data collection interval. If the value of
unavailable seconds in a particular 15-minute collectio…
secondsHC-PerfHist-TC-MIBHCPerfIntervalThresholdr/w
Type Constraints:
range: 0..900
.1.3.6.1.2.1.10.97.1.1.20.1.8
vdslLineAlarmConfInitFailureThis object specifies if a vdslInitFailureNotification
notification will be generated if an initialization
failure occurs.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.2.1.10.97.1.1.20.1.9
vdslLineAlarmConfProfRowStatusThis object is used to create a new row or modify or
delete an existing row in this table.

A profile activated by setting this object to 'active'.
When 'active' is set, the system will validate the profil…
SNMPv2-TCRowStatusr/w
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.2.1.10.97.1.1.20.1.10