uxAlarmActiveCount
UX-OBJECTS-MIB ·
.1.3.6.1.4.1.177.15.1.3.1.11
Object
column
Integer32
Number of times this alert occurred. This count is relevant only for non-auto-cancelling alerts.
Context
- MIB
- UX-OBJECTS-MIB
- OID
.1.3.6.1.4.1.177.15.1.3.1.11- Type
- column
- Access
- readonly
- Status
- current
- Parent
- uxActAlarmEntry
- Table
- uxActAlarmTable
- Siblings
- 18
Syntax
Integer32
Values & Constraints
Object Constraints
range: 1-2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| uxAlarmActiveIndex Index of Active alarm table | column | Integer32 | .1.3.6.1.4.1.177.15.1.3.1.1 |
| uxAlarmActiveLastOccur Alarm last occurrence Time displayed in milli sec. | column | SNMPv2-SMICounter64 | .1.3.6.1.4.1.177.15.1.3.1.10 |
| uxAlarmActiveDecodeKey Decode key that is used to interpret alarm/event instances when the
alarms are posted to active alarm Table.
The index attribute uxAlarmInstanceID is decoded based … | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.177.15.1.3.1.12 |
| uxAlarmActiveSourceInstance Instance that has generated this alert. This is encoded as
illustrated in the following example :
decode key = shelf;card;port
Source instance = 1;1;1 indicates that the ale… | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.177.15.1.3.1.13 |
| uxAlarmActiveState Informs if an active alarm is acknowledged/unacknowledged/cancelled. | column | Enumeration | .1.3.6.1.4.1.177.15.1.3.1.14 |
| uxAlarmActiveClrEvtID Clearing event Event ID of this alarm. Applicable to the alarms for which the auto clear is set | column | Integer32 | .1.3.6.1.4.1.177.15.1.3.1.15 |
| uxAlarmActiveClrEvtSubID Clearing event Event sub ID of this alarm. Applicable to the alarms for which the auto clear is set. | column | Integer32 | .1.3.6.1.4.1.177.15.1.3.1.16 |
| uxAlarmActiveDescription Alarm description. Any info user wants to note | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.177.15.1.3.1.17 |
| uxAlarmActiveHighestSeverityAlarm Highest Severity Active alarm | column | Integer32 | .1.3.6.1.4.1.177.15.1.3.1.18 |
| uxAlarmActiveHardWareID Hardware ID of the node | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.177.15.1.3.1.19 |
| uxAlarmConfigIndex Index value of Alarm configuration number | column | Integer32 | .1.3.6.1.4.1.177.15.1.3.1.2 |
| uxAlarmActiveID EventID of the active alarm | column | Integer32 | .1.3.6.1.4.1.177.15.1.3.1.3 |
| uxAlarmActiveSubID EventID of the active alarm | column | Integer32 | .1.3.6.1.4.1.177.15.1.3.1.4 |
| uxAlarmActiveCondition Active alarm/event name. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.177.15.1.3.1.5 |
| uxAlarmActiveSeverity Alarm severity level.
Eg: none
warning
minor
major
critical | column | Enumeration | .1.3.6.1.4.1.177.15.1.3.1.6 |
| uxAlarmActiveCategory Alarm/event category number. As per Bell Core Standard GR-1248-CORE | column | Enumeration | .1.3.6.1.4.1.177.15.1.3.1.7 |
| uxAlarmActiveCancelType When an alarm is configured as auto-cancel(1), it clears from
the UX active alarm table, when the condition causing it goes away.
These alarms do not need explicit user interventi… | column | Enumeration | .1.3.6.1.4.1.177.15.1.3.1.8 |
| uxAlarmActiveFirstOccur Alarm first occurrence Time displayed in milli sec. | column | SNMPv2-SMICounter64 | .1.3.6.1.4.1.177.15.1.3.1.9 |