utsEponModuleCSMSwitchtime
UTEPON4000CONF-MIB ·
.1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.11
Object
column
SNMPv2-SMITimeTicks
when the oepration state of this module become active.
Context
- MIB
- UTEPON4000CONF-MIB
- OID
.1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.11- Type
- column
- Access
- readonly
- Status
- current
- Parent
- utsEponModuleBoardEntry
- Table
- utsEponModuleBoardTable
- Siblings
- 24
Syntax
SNMPv2-SMITimeTicks
- Source
- SNMPv2-SMITimeTicks
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| utsEponModuleBoardPhyId The physical module number, 1-12 means service card, 13 means CSM A, 14 means CSM B. | column | Integer32 | .1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.1 |
| utsEponModuleBoardSwVer Software version of the board. The software verion is applicable
to the whole box and therefore belongs to the GSM board. For LTM
boards, the this object returns 'None'. | column | OctetString | .1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.12 |
| utsEponModuleBoardBootromVer The Bootrom version of the board. The Bootrom verion is
applicable to the whole box and therefore belongs to the GSM board.
For LTM boards, the this object returns 'None'. | column | OctetString | .1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.13 |
| utsEponModuleBoardPassaveVer The Passave Olt Firmware revision for the LTM board. Each of the
two LTM boards has a copy of the firmware running therefore both
will show a firmware version. For now, however… | column | OctetString | .1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.14 |
| utsEponModuleBoardCurTemp The current temperature of physical slot. | column | Integer32 | .1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.15 |
| utsEponModuleBoardTempUpLimit The maximum threshold of physical slot temperature. The default value is 70.
It is suggested this value shall be greater than up clear limit value for 5. | column | Integer32 | .1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.16 |
| utsEponModuleBoardTempUpClearLimit The up clear limit of physical slot temperature. The default value is 65.
It is suggested this value shall be lower than up limit value for 5. | column | Integer32 | .1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.17 |
| utsEponModuleBoardLastAdminStateChangetime Last Administrative State Change Time Till Now (TimeTicks). | column | SNMPv2-SMITimeTicks | .1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.18 |
| utsEponModuleBoardLastOperationStateChangetime Last Operational State Change Time Till Now (TimeTicks). | column | SNMPv2-SMITimeTicks | .1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.19 |
| utsEponModuleBoardType The line card type. In bbs4000, current 4 kind board are supported:
csm(2) -- controller and switch fabric card,
epm04a(3) -- epon service access line card using the Passave Chip,… | column | Enumeration | .1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.2 |
| utsEponModuleBoardDisableCause The disable Cause. | column | Enumeration | .1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.20 |
| utsEponModuleBoardHwVer Hw version of the board | column | OctetString | .1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.21 |
| utsEponModuleBoardCpldVer CPLD version of the board | column | OctetString | .1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.22 |
| utsEponModuleBoardSerialNumber SN information of the board | column | OctetString | .1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.23 |
| utsEponModuleBoard2424Information 2424 information of the board | column | OctetString | .1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.24 |
| utsEponModuleBoardHASyncStatus The HA Sync status for the initial sync when the standby card insert. | column | Enumeration | .1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.26 |
| utsEponModuleBoardCpuUtil The current cpu util of the board, in the current system, only csm board should be readed, and
the value should be from 0 to 1000. | column | Integer32 | .1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.27 |
| utsEponModuleBoardMemUtil The current memory util of the board, in the current system, only csm board should be readed, and
the value should be from 0 to 1000. | column | Integer32 | .1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.28 |
| utsEponModulePhyPresenceStat The line card type. In EPON, BCM, OLT are supported | column | Enumeration | .1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.3 |
| utsEponModuleAdminState administrative state changed by operator,
locked(1) -- the slot is disabled for service
unlocked (2) -- the slot can provide service
reset(8) -- reset the slot | column | Enumeration | .1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.4 |
| utsEponModuleOperationState The internal state of line card | column | Enumeration | .1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.5 |
| utsEponModuleRedundancyState The redundancy state of CSM module, for other line card, the unique state is other(1). | column | Enumeration | .1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.6 |
| utsEponModulePhyicalUptime when the physical module is up. | column | SNMPv2-SMITimeTicks | .1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.8 |
| utsEponOpStateUptime when the oepration state of this module become active. | column | SNMPv2-SMITimeTicks | .1.3.6.1.4.1.1949.1.3.10.200.6.2.1.1.1.1.9 |