tnSyncEBITSPortLbo
TROPIC-SYNCE-MIB ·
.1.3.6.1.4.1.7483.2.2.4.8.2.1.6.1.8
Object
column
r/w
Enumeration
Line equalization value for the BITS output port,
taking one of the following values:
- lbo: no compensation
- lbo1: 0 to 133 feet
- lbo2: 133 to 266 feet
- lbo3: 267 to 399 feet
- lbo4: 400 to 533 feet
- lbo5: 534 to 655 feet
This attribute is applicable when tnSyncEBITSPortSignalType
is DS1 SF or DS1 ESF.
Context
- MIB
- TROPIC-SYNCE-MIB
- OID
.1.3.6.1.4.1.7483.2.2.4.8.2.1.6.1.8- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- tnSyncEBITSPortEntry
- Table
- tnSyncEBITSPortTable
- Siblings
- 8
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | lbo |
2 | lbo1 |
3 | lbo2 |
4 | lbo3 |
5 | lbo4 |
6 | lbo5 |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| tnSyncEBITSPortDirection Indicate the direction of the BITS port. | column | Enumeration | .1.3.6.1.4.1.7483.2.2.4.8.2.1.6.1.1 |
| tnSyncEBITSPortSignalType Specify the signal type for the BITS interface:
0 - 2MHz
1 - unframed E1
2 - framed E1 without SSM
3 - framed E1 with SSM
4 - DS1 SF
5 - DS1 ESF.
In SDH mode, 2MHz … | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.7483.2.2.4.8.2.1.6.1.2 |
| tnSyncEBITSPortSaBit Specifies the Sa bit location used to carry the
SSM information. This parameter is only
applicable when tnSyncEBITSPortSignalType = 3
(framed E1 with SSM) | column | Enumeration | .1.3.6.1.4.1.7483.2.2.4.8.2.1.6.1.3 |
| tnSyncEBITSPortOutputSSMTrans The port SSM/Quality Level Transmission value.
The value can be:
In SDH mode - act, prc, ssua, ssub, sec,
dnu, none;
In sonet mode - act, stu, prs, st2, st… | column | Enumeration | .1.3.6.1.4.1.7483.2.2.4.8.2.1.6.1.4 |
| tnSyncEBITSPortOutputAISMode Specifies which signal is inserted for the timing
output port if the output signal is squelched.
The parameter is only applicable for output port
types supporting SSM.
AISMODE -… | column | Enumeration | .1.3.6.1.4.1.7483.2.2.4.8.2.1.6.1.5 |
| tnSyncEBITSPortLineImpedance Nominal line impedance.
When in SDH mode, imp75ohms or imp120ohms could
be used and the default is imp120ohms. When in
ONET mode, imp100ohms could be used and the default
is imp1… | column | Enumeration | .1.3.6.1.4.1.7483.2.2.4.8.2.1.6.1.6 |
| tnSyncEBITSPortLineCode Line code. This attribute is applicable when
tnSyncEBITSPortSignalType is DS1 SF or DS1 ESF. | column | Enumeration | .1.3.6.1.4.1.7483.2.2.4.8.2.1.6.1.7 |
| tnSyncEBITSPortAlmProfName Alarm profile for BITs port | column | OctetString | .1.3.6.1.4.1.7483.2.2.4.8.2.1.6.1.9 |