tnPortHoldTimeUp

TN-PORT-MIB · .1.3.6.1.4.1.7483.6.1.2.2.4.2.1.14

Object

column r/w Unsigned32
The value of tnPortHoldTimeUp is used to configure the
hold-timer for link up event dampening. This guards against
reporting excessive interface transitions. This is implemented
by not advertising subsequent transitions of the interface to
upper layer protocols until the configured timer has expired.
A value of zero (0) indicates that an up transition is reported
immediately.  The value of tnPortHoldTimeUp is not applicable
when tnPortClass has a value of 'sonet (5)'. In that case,
tnSonetHoldTimeUp is used instead.
              
tnPortHoldTimeUp is measured in units as specified by
tnPortHoldTimeUnits. The maximum hold-time for this object is
15 minutes, regardless of the units specified. Attempts to change
the maximum value to a hold-time longer than 15 minutes will result
in an INCONSISTENT error.

Context

MIB
TN-PORT-MIB
OID
.1.3.6.1.4.1.7483.6.1.2.2.4.2.1.14
Type
column
Access
readwrite
Status
current
Parent
tnPortEntry
Table
tnPortTable
Siblings
64

Syntax

Unsigned32

Values & Constraints

Object Constraints
range: 0-90000

Related Objects

Sibling Objects