tnPortHoldTimeUp
TN-PORT-MIB ·
.1.3.6.1.4.1.7483.6.1.2.2.4.2.1.14
Object
column
r/w
Unsigned32
The value of tnPortHoldTimeUp is used to configure the
hold-timer for link up event dampening. This guards against
reporting excessive interface transitions. This is implemented
by not advertising subsequent transitions of the interface to
upper layer protocols until the configured timer has expired.
A value of zero (0) indicates that an up transition is reported
immediately. The value of tnPortHoldTimeUp is not applicable
when tnPortClass has a value of 'sonet (5)'. In that case,
tnSonetHoldTimeUp is used instead.
tnPortHoldTimeUp is measured in units as specified by
tnPortHoldTimeUnits. The maximum hold-time for this object is
15 minutes, regardless of the units specified. Attempts to change
the maximum value to a hold-time longer than 15 minutes will result
in an INCONSISTENT error.
Context
- MIB
- TN-PORT-MIB
- OID
.1.3.6.1.4.1.7483.6.1.2.2.4.2.1.14- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- tnPortEntry
Syntax
Unsigned32
Values & Constraints
Object Constraints
range: 0-90000