tnDot3OamInterval
TN-DOT3-OAM-MIB ·
.1.3.6.1.4.1.7483.6.1.2.42.1.1.1.2
Object
column
r/w
100s of milliseconds Unsigned32
The value of tnDot3OamInterval specifies the number of 100ms time intervals between each periodic OAMPDU transmit and receive. A lower value implies that OAMPDUs will be transmitted more frequently to the peer, and OAMPDUs must be received more frequently from the peer. The default is set to 10, meaning 1 second between transmits and receives.
Context
- MIB
- TN-DOT3-OAM-MIB
- OID
.1.3.6.1.4.1.7483.6.1.2.42.1.1.1.2- Type
- column
- Access
- readwrite
- Status
- current
- Units
- 100s of milliseconds
- Parent
- tnDot3OamEntry
Syntax
100s of milliseconds Unsigned32
Values & Constraints
Object Constraints
range: 1-600