tmnxSvcSysEthSegPortId

TIMETRA-SERV-MIB · .1.3.6.1.4.1.6527.3.1.2.4.2.184.1.9

Object

The value of tmnxSvcSysEthSegPortId specifies the port associated with
this ethernet segment entry.
              
The default value indicates an invalid port.
              
An 'inconsistentValue' error is returned if more than one of
tmnxSvcSysEthSegLagId, tmnxSvcSysEthSegPortId, tmnxSvcSysEthSegSdpId
is set to non-default value.

Context

MIB
TIMETRA-SERV-MIB
OID
.1.3.6.1.4.1.6527.3.1.2.4.2.184.1.9
Type
column
Access
readwrite
Status
current
Default
503316480
Parent
tmnxSvcSysEthSegEntry
Groups
5

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'TIMETRA-SERV-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-SERV-MIB::tmnxSvcSysEthSegPortId'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'TIMETRA-SERV-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-SERV-MIB::tmnxSvcSysEthSegPortId.<tmnxSvcSysEthSegName>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'TIMETRA-SERV-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'TIMETRA-SERV-MIB::tmnxSvcSysEthSegPortId'

Syntax

Source
TIMETRA-TC-MIBTmnxPortID
Base type
Unsigned32
Type Description
A portid is a unique 32 bit number with special encoding.
          
Refer to TIMETRA-CHASSIS-MIB::tmnxChassisPortIdScheme for a
description of the various port mapping schemes used by the system for
physical ports and channels.
          
An 'invalid portid' is a TmnxPortID with a value of 0x1e000000.

Values & Constraints

No enumerated values or constraints recorded.