tmnxSonetPathC2Byte

TIMETRA-PORT-MIB · .1.3.6.1.4.1.6527.3.1.2.2.4.6.1.5

Object

column r/w Unsigned32
The tmnxSonetPathC2Byte variable is used configure the value used in
the SONET/SDH C2 header byte.
              
For paths on an MDA that does not support channelization: Setting C2
equal to 0x16 indicates scrambled sonet.
              
Setting C2 equal to 0xCF indicates unscrambled sonet.
              
Setting C2 equal to 0x13 indicates ATM.
              
For paths on an MDA that supports channelization, the default value is
based on the value of tmnxMDAMaxChannelization. For 'pdhDs3' or
'pdhE3' channelization, the default value is 0x04.
              
Setting tmnxSonetPathC2Byte to a value of zero(0) causes the agent to
assign the default value to this object.

Context

MIB
TIMETRA-PORT-MIB
OID
.1.3.6.1.4.1.6527.3.1.2.2.4.6.1.5
Type
column
Access
readwrite
Status
current
Parent
tmnxSonetPathEntry
Groups
1

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'TIMETRA-PORT-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-PORT-MIB::tmnxSonetPathC2Byte'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'TIMETRA-PORT-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-PORT-MIB::tmnxSonetPathC2Byte.<tmnxChassisIndex>.<tmnxPortPortID>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'TIMETRA-PORT-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'TIMETRA-PORT-MIB::tmnxSonetPathC2Byte'

Syntax

Unsigned32

Values & Constraints

Object Constraints
range: 0-254

Conformance