tmnxRS232ControlLeadSignal

TIMETRA-PORT-MIB · .1.3.6.1.4.1.6527.3.1.2.2.4.112.1.18

Object

column OctetString
tmnxRS232ControlLeadSignal values are used to indicate
the current signal levels of the input and output control leads
(connected to the attached CPE). These values are the ones that get
signalled over the (physical) line. As such, they are sometimes
referred to as LINE-side values.
  -- DtrDsr (LSB or byte0)
  -- RtsDcdC
  -- AlbCts
  -- RdlRi
  -- DsrDtr
  -- DcdRtsI
  -- CtsAlb
  -- RiRdl (MSB or byte7)
              
A bit value of 1 represents on (or high). A bit value of 2 represents
off (or low).

Context

MIB
TIMETRA-PORT-MIB
OID
.1.3.6.1.4.1.6527.3.1.2.2.4.112.1.18
Type
column
Access
readonly
Status
current
Parent
tmnxRS232Entry
Groups
1

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'TIMETRA-PORT-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-PORT-MIB::tmnxRS232ControlLeadSignal'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'TIMETRA-PORT-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-PORT-MIB::tmnxRS232ControlLeadSignal.<tmnxChassisIndex>.<tmnxPortPortID>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'TIMETRA-PORT-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'TIMETRA-PORT-MIB::tmnxRS232ControlLeadSignal'

Syntax

OctetString

Values & Constraints

Object Constraints
range: 8-8

Conformance