tmnxPortEtherReportAlarm
TIMETRA-PORT-MIB ·
.1.3.6.1.4.1.6527.3.1.2.2.4.4.1.15
Object
The value of tmnxPortEtherReportAlarm determines when and if to generate tmnxEqPortEtherAlarm and tmnxEqPortEtherAlarmClear.
Context
- MIB
- TIMETRA-PORT-MIB
- OID
.1.3.6.1.4.1.6527.3.1.2.2.4.4.1.15- Type
- column
- Access
- readwrite
- Status
- current
- Default
(remoteFault, localFault)- Parent
- tmnxPortEtherEntry
- Groups
- 5
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'TIMETRA-PORT-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-PORT-MIB::tmnxPortEtherReportAlarm'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'TIMETRA-PORT-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-PORT-MIB::tmnxPortEtherReportAlarm.<tmnxChassisIndex>.<tmnxPortPortID>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'TIMETRA-PORT-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'TIMETRA-PORT-MIB::tmnxPortEtherReportAlarm'
Syntax
- Source
- TmnxPortEtherReportStatus
- Base type
Bits
Type Description
The TmnxPortEtherReportStatus is a bitmask that describes alarms that
can be raised/cleared on an Ethernet Port.
The possible values are:
notUsed (0) - not applicable
signalFailure(1) - Ethernet signal lost alarm
When the optic module declares a loss of signal, the MAC will
declare localFault(3) and the PCS will declare noBlockLock(6).
remoteFault (2) - Remote Fault
See localFault(3).
localFault (3) - Local Fault
Defined in IEEE 802.3ba Clause 81.3.4.
When the PCS detects a fault it generates a localFault(3)
towards the MAC layer. The MAC layer responds by sending a
remoteFault(2) to the far end. A local fault can get caused
by any of the PCS layer defects below.
noFrameLock (4) - Not locked on the Ethernet framing sequence
Defined in IEEE 802.3ba Clause 82.2.13.
The frame lock is obtained when all lanes have 64B/66B block
sync, been deskewed, and alignment marker lock.
highBer (5) - High Bit Error Rate
Defined in IEEE 802.3ba Clause 82.2.18.2.2.
Bit error ratio > 10^-4.
noBlockLock (6) - 40G/100G PCS Lanes Not Block Locked
Defined in IEEE 802.3ba Clause 82.2.11.
Cleared once all lanes have 64B/66B block lock.
noAmLock (7) - 40G/100G PCS Alignment Marker Loss of Lock
Defined in IEEE 802.3ba Clause 82.2.12.
Cleared once all lanes alignment marker lock.
duplicateLane(8) - 40G/100G PCS Duplicate Lane Marker
Not defined in the standard.
Raised when two or more lanes are seen with the same alignment
marker.
Values & Constraints
Type Values
0 | notUsed |
1 | signalFailure |
2 | remoteFault |
3 | localFault |
4 | noFrameLock |
5 | highBer |
6 | noBlockLock |
7 | noAmLock |
8 | duplicateLane |