tmnxPortEtherDownWhenLoopedKeepAlive

TIMETRA-PORT-MIB · .1.3.6.1.4.1.6527.3.1.2.2.4.4.1.22

Object

column r/w secondsUnsigned32
The tmnxPortEtherDownWhenLoopedKeepAlive variable specifies the number
of seconds between each keep alive PDU transmission.

Context

MIB
TIMETRA-PORT-MIB
OID
.1.3.6.1.4.1.6527.3.1.2.2.4.4.1.22
Type
column
Access
readwrite
Status
current
Units
seconds
Default
10
Parent
tmnxPortEtherEntry
Groups
3

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'TIMETRA-PORT-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-PORT-MIB::tmnxPortEtherDownWhenLoopedKeepAlive'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'TIMETRA-PORT-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-PORT-MIB::tmnxPortEtherDownWhenLoopedKeepAlive.<tmnxChassisIndex>.<tmnxPortPortID>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'TIMETRA-PORT-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'TIMETRA-PORT-MIB::tmnxPortEtherDownWhenLoopedKeepAlive'

Syntax

secondsUnsigned32

Values & Constraints

Object Constraints
range: 1-120