tmnxDS1PortLineImpedance

TIMETRA-PORT-MIB · .1.3.6.1.4.1.6527.3.1.2.2.4.23.1.7

Object

column r/w OhmsUnsigned32
The value of tmnxDS1PortLineImpedance specifies the line  impedance
set on the physical DS1/E1 port.
              
A DS1 port can only be set to 100 Ohms. An E1 port can only be set to
75 Ohms or 120 Ohms. The default is 120 Ohms.

Context

MIB
TIMETRA-PORT-MIB
OID
.1.3.6.1.4.1.6527.3.1.2.2.4.23.1.7
Type
column
Access
readwrite
Status
current
Units
Ohms
Parent
tmnxDS1PortEntry
Groups
1

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'TIMETRA-PORT-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-PORT-MIB::tmnxDS1PortLineImpedance'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'TIMETRA-PORT-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-PORT-MIB::tmnxDS1PortLineImpedance.<tmnxChassisIndex>.<tmnxPortPortID>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'TIMETRA-PORT-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'TIMETRA-PORT-MIB::tmnxDS1PortLineImpedance'

Syntax

OhmsUnsigned32

Values & Constraints

Object Constraints
range: 75-75 range: 100-100 range: 120-120

Conformance