tmnxOtuIfCfgAlarms
TIMETRA-OTU-MIB ·
.1.3.6.1.4.1.6527.3.1.2.62.1.1.1.9
Object
The value of tmnxOtuIfCfgAlarms specifies the alarms that are to be monitored by the OTU interface. If an alarm bit is set, then the corresponding alarm will raise/clear an alarm when its state changes. An unset bit specifies that the alarm corresponding with the bit will not alarm on its state transitions.
Context
- MIB
- TIMETRA-OTU-MIB
- OID
.1.3.6.1.4.1.6527.3.1.2.62.1.1.1.9- Type
- column
- Access
- readwrite
- Status
- current
- Default
(loc, los, lof, lom, otuBerSf, otuBdi, fecSf)- Parent
- tmnxOtuIfEntry
- Groups
- 2
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'TIMETRA-OTU-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-OTU-MIB::tmnxOtuIfCfgAlarms'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'TIMETRA-OTU-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-OTU-MIB::tmnxOtuIfCfgAlarms.<ifIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'TIMETRA-OTU-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'TIMETRA-OTU-MIB::tmnxOtuIfCfgAlarms'
Syntax
- Source
- TmnxOtuAlarms
- Base type
Bits
Type Description
The TmnxOtuAlarms specifies the alarms which are enabled or
outstanding against an OTU enabled interface. The valid alarms are as
follows:
- loc - Loss of Clock.
- los - Loss of Signal.
- lof - Loss of OTU Framing.
- lom - Loss of Multi-frame.
- otuAis - OTU Alarm Indication Signal.
- otuBerSf - OTU Bit Error Rate Signal Fail.
- otuBerSd - OTU Bit Error Rate Signal Degradation.
- otuBdi - OTU Backward Defect Indication.
- otuTim - OTU Trace ID Mismatch.
- otuIae - OTU Incoming Alignment Error.
- otuBiae - OTU Backward Incoming Alignment Error.
- fecSf - FEC Signal Failure.
- fecSd - FEC Signal Degradation.
- fecFail - FEC Rx/Tx mode mismatch (enhanced/g709fec)
or High uncorrectable bit rate (>10E-2).
- fecUncorr - One or more uncorrectable FEC errors.
- oduAis - Optical Data Unit (ODU) Alarm Indication
Signal.
- oduOci - ODU Open Connection Indication.
- oduLck - ODU Locked.
- oduBdi - PM Backward Defect Indication.
- oduTim - PM Trace ID Mismatch.
- opuPlm - OPU PSI Payload Type Mismatch.
Values & Constraints
Type Values
0 | loc |
1 | los |
2 | lof |
3 | lom |
4 | otuAis |
5 | otuBerSf |
6 | otuBerSd |
7 | otuBdi |
8 | otuTim |
9 | otuIae |
10 | otuBiae |
11 | fecSf |
12 | fecSd |
13 | fecFail |
14 | fecUncorr |
15 | oduAis |
16 | oduOci |
17 | oduLck |
18 | oduBdi |
19 | oduTim |
20 | reserved20 |
21 | opuPlm |